研究者業績
基本情報
研究分野
1経歴
6-
2022年1月 - 現在
-
2020年10月 - 2021年12月
-
2016年4月 - 2020年10月
-
2015年4月 - 2016年3月
-
2014年4月 - 2015年3月
論文
12-
JA clinical reports 11(1) 64-64 2025年11月3日BACKGROUND: Transesophageal echocardiography (TEE) is widely used in cardiac and non-cardiac surgeries with major hemodynamic fluctuations. In patients with vascular anomalies near the esophagus, such as an aberrant left subclavian artery (ALSA), TEE may pose a risk of vascular compression. However, no guidelines exist. CASE PRESENTATION: A 19-year-old woman with biliary atresia underwent living donor liver transplantation. Preoperative imaging showed a right-sided aortic arch with ALSA coursing posterior to the esophagus, and ALSA compression was considered a risk during TEE. Therefore, bilateral radial arterial pressures and regional cerebral oxygen saturation (rSO₂) were monitored. The TEE probe was inserted under videolaryngoscopic guidance without resistance or hemodynamic disturbance, and no arterial waveform attenuation or rSO₂ changes occurred. Transplantation was uneventful, and the patient showed no postoperative neurological or upper-limb deficits. CONCLUSION: This case highlights that appropriate imaging and monitoring strategies can support safe TEE use in non-cardiac surgery, even with vascular anomalies.
-
The Journal of dermatology 52(11) e983-e985 2025年11月
-
Fujita medical journal 11(4) 161-164 2025年11月OBJECTIVES: Subcutaneous emphysema (SE) in pneumoperitoneum surgery is a complication not observed in open abdominal surgery, but data are scarce and epidemiology is inadequate. Although SE is considered less problematic because it is caused by carbon dioxide gas, past reports have shown that severe complications can occur, such as airway obstruction and cardiopulmonary collapse. We conducted an exploratory single-center retrospective study of patients admitted to the ICU after robotic or conventional laparoscopic abdominal surgery, focusing on epidemiological factors promoting severe SE. METHODS: This retrospective study examined cases of severe SE following robotic or conventional laparoscopic abdominal surgery that necessitated ICU admission. Patients older than 18 years with unscheduled ICU admission for grade 5 head SE between 1 January 2010 and 31 December 2021 were included. All robotic surgeries used the da Vinci Surgical System. RESULTS: We reviewed data from all 8 of 3,532 robotic surgeries and 5 of 10,305 conventional laparoscopic surgeries resulting in severe SE. By approach, the incidence of severe SE was 0.23% for robotic surgery and 0.05% for laparoscopic surgery (p=0.006). By organ, gastric surgery was the leading cause, with 6 cases from 2,224 gastric surgeries and 7 from a total of 11,613 other abdominal surgeries, giving incidences of 0.27% and 0.06%, respectively (p=0.011). The incidence in women was 0.15% (10/6,496), compared with only 0.04% (3/7,341) in men (p=0.048). CONCLUSIONS: Our findings confirmed that higher risk of severe SE-although still small-is associated with robotic and gastric surgeries and female sex.
-
Cureus 17(8) e89866 2025年8月Currently, sodium-glucose co-transporter 2 inhibitors (SGLT2is) are used frequently in a range of patients, including those with type 1 diabetes mellitus, raising concerns regarding the potential increased risk of SGLT2i-associated euglycemic diabetic ketoacidosis (EDKA). We report the case of a patient with type 1 diabetes who developed SGLT2i-associated EDKA during the perioperative period of concurrent pancreas and kidney transplantation procedure. A 41-year-old woman taking an SGLT2i underwent concurrent pancreas and kidney transplantation from a brain-dead donor. Acidosis was noted during surgery, which improved temporarily after the pancreas was transplanted. The pancreatic allograft was resected because of twisting of the anastomotic vessels, and acidosis recurred. The patient's blood glucose levels were consistently within the normal range. Blood ketone monitoring was initiated, and the patient was diagnosed with EDKA. Patients with type 1 diabetes taking SGLT2is who undergo emergency surgery are at risk of EDKA and should continually monitor their ketone levels.
-
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 28(1) 95-101 2025年3月A simple and robust method for veno-venous extracorporeal membrane oxygenation (V-V ECMO) involves a drainage cannula into the inferior vena cava via the femoral vein (FV) and a reinfusion cannula into the right atrium (RA) via the internal jugular vein (IJV) (F-J configuration). However, with this method, the arterial oxygen (PaO2) is said to remain below 100 mmHg.Since recently, in our ICU, to prevent drainage failure, we apply a modification from the commonly practiced F-J configuration by advancing the tip of the drainage cannula inserted via the FV into the superior vena cava (SVC) and crossing the reinfusion cannula inserted via the IJV in the RA (F(SVC)-J(RA) configuration). We experienced that this modification can be associated with unexpectedly high PaO2 values, which here we investigated in detail.Veno-arteriovenous ECMO was induced in a 65-year-old male patient who suffered from repeated cardiac arrest due to acute respiratory distress syndrome. His chest X-ray images showed white-out after lung rest setting, consistent with near-absence of self-lung ventilation. Cardiac function recovered and the system was converted to F(SVC)-J(RA) configuration, after which both PaO2 and partial pressure of pulmonary arterial oxygen values remained high above 200 mmHg. Transesophageal echocardiography could not detect right-to-left shunt, and more efficient drainage of the native venous return flow compared to common F-J configuration may explain the increased PaO2.Although the F(SVC)-J(RA) configuration is a small modification of the F-J configuration, it seems to provide a revolutionary improvement in the ECMO field by combining robustness/simplicity with high PaO2 values.
-
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 27(3) 306-310 2024年9月We report a case in which excessive negative pressure may have been applied to the proximal side hole of a drainage cannula during venovenous extracorporeal membrane oxygenation (V-V ECMO), resulting in abnormal stenosis of the drainage cannula. V-V ECMO was introduced in a 71-year-old male patient who was transferred from another hospital for severe respiratory failure associated with varicella pneumonia and acute respiratory distress syndrome. Drainage was performed using a PCKC-V™ 24Fr (MERA, Japan) cannula via the right femoral vein with the tip of the cannula near the level of the diaphragm under fluoroscopy. Reinfusion was performed via the right internal jugular vein. Due to poor systemic oxygenation, the drainage cannula was withdrawn caudally and refixed to reduce the effect of recirculation. Two days later, drainage pressure dropped rapidly, and frequent ECMO flow interruption occurred due to poor drainage. An abdominal X-ray revealed abnormal stenosis of the proximal side hole site of the drainage cannula. We diagnosed that the drainage cannula was damaged, and it was replaced with another, namely a Medtronic Bio-Medicus™ 25 Fr (GETINGE, Sweden) cannula. However, the removed drainage cannula was not damaged, suggesting that the cannula was temporarily stenosed by momentary excessive negative pressure. In a multi-stage drainage cannula, the main drainage site is the proximal side hole, with little negative pressure applied at the apical foramen in a mock experimental ex vivo drainage test in a water tank. Hence, improvement of a multi-stage drainage cannula is recommended, such as adequate reinforcement of the side hole site with a wire.
-
Journal of cardiothoracic surgery 19(1) 358-358 2024年6月24日BACKGROUND: Infective endocarditis (IE) is a rare cardiovascular complication in patients with coronavirus disease 2019 (COVID-19). IE after COVID-19 can also be complicated by acute respiratory distress syndrome (ARDS); however, the guidelines for the treatment of such cases are not clear. Here, we report a case of perioperative management of post-COVID-19 IE with ARDS using veno-venous extracorporeal membrane oxygenation (V-V ECMO). CASE PRESENTATION: The patient was a 40-year-old woman who was admitted on day 18 of COVID-19 onset and was administered oxygen therapy, remdesivir, and dexamethasone. The patient's condition improved; however, on day 24 of hospitalization, the patient developed hypoxemia and was admitted to the intensive care unit (ICU) due to respiratory failure. Blood culture revealed Corynebacterium striatum, and transesophageal echocardiography revealed vegetation on the aortic and mitral valves. Valve destruction was mild, and the cause of respiratory failure was thought to be ARDS. Despite continued antimicrobial therapy, ARDS did not improve the patient's condition, and valve destruction progressed; therefore, surgical treatment was scheduled on day 13 of ICU admission. After preoperative consultation with the team, a decision was made to initiate V-V ECMO after the patient was weaned from CPB, with concerns about further worsening of her respiratory status after surgery. The patient returned to the ICU with transition to V-V ECMO, and her circulation remained stable. The patient was weaned off V-V ECMO on postoperative day 33 and discharged from the ICU on postoperative day 47. CONCLUSIONS: ARDS may occur in patients with IE after COVID-19. Owing to concerns about further exacerbation of pulmonary damage, the timing of surgery should be comprehensively considered. Preoperatively, clinicians should discuss perioperative ECMO introduction and configuration.
-
JA clinical reports 9(1) 54-54 2023年8月26日BACKGROUND: Hemodynamic management during anesthesia in liver transplantation for patients with polycystic liver disease (PLD) can be more challenging because of the bleeding and hemodynamic alterations due to the markedly enlarged liver. We hereby report a case of PLD wherein transesophageal echocardiography (TEE) was employed for optimal hemodynamic monitoring during liver transplantation. CASE PRESENTATION: A 61-year-old man was scheduled to undergo liver transplantation for massive PLD. Hemodynamic instability was associated with mechanical displacement of the giant cystic liver. TEE results revealed the collapse of the inferior vena cava due to liver displacement. TEE also detected intrathoracic hemorrhage triggered by detachment from the markedly enlarged liver. CONCLUSION: TEE is a valuable monitoring tool for sharing information with surgeons and diagnostic modality for finding the source of bleeding in liver transplantation for PLD and may contribute majorly to the quality of perioperative management.
-
Fujita medical journal 9(3) 179-185 2023年8月OBJECTIVES: Perioperative venous thromboembolism (VTE) is a potentially fatal complication, making preoperative VTE diagnosis and secondary thromboprophylaxis important. This study was performed to investigate the impact of promotion of a preoperative VTE protocol at a perioperative management center (PMC) on detecting the preoperative VTE rate and subsequent treatment. METHODS: This retrospective study involved patients aged ≥20 years who underwent elective anesthesia. The patients were divided into two groups: the pre-PMC group (January to October 2014, before the opening of the PMC) and the post-PMC group (January to December 2019, after the opening of the PMC). The rates of preoperative lower-limb compression ultrasonography (CUS), VTE detection, anticoagulation therapy, and new postoperative pulmonary embolism (PE) were compared between the two groups. RESULTS: The pre-PMC and post-PMC groups comprised 3737 and 5388 patients, respectively. The preoperative CUS and VTE detection rates were significantly higher in the post-PMC than pre-PMC group (7.2% and 1.43% vs. 25.6% and 3.93%, respectively; P<0.001). There was no significant difference in the rate of anticoagulation therapy in patients with preoperative VTE (88.9% vs. 84.7%, P=0.43). Heparin and direct oral anticoagulants were primarily used in the pre-PMC and post-PMC groups, respectively. The efficacy and safety were comparable between the two groups. No new postoperative PE was detected in either group. CONCLUSIONS: Promotion of the preoperative VTE protocol led by the PMC increased the rates of preoperative CUS and preoperative VTE detection. This may aid in secondary thromboprophylaxis in the preoperative period and prevention of postoperative PE.
-
The Tohoku journal of experimental medicine 259(2) 121-126 2023年1月21日Postreperfusion syndrome is one of the responsible mechanisms of portal hypertension in patients undergoing liver transplantation. And post-transplant portal hypertension causes graft dysfunction. Postreperfusion syndrome is characterized by a decrease in arterial pressure and cardiac output, and an increase in central venous pressure, pulmonary artery pressure, and pulmonary vascular resistance that occurs after the release of the portal vein clamp. Although early recovery from postreperfusion syndrome is desired, there is a little medication therapy such as the administration of calcium chloride, sodium bicarbonate, and beta-agonist for postreperfusion syndrome. We present a case of postreperfusion syndrome manifested as post-transplant portal hypertension and reversed after nitroglycerin administration. A 49-year-old Asian woman was scheduled for liver transplantation because of Budd-Chiari syndrome. After portal vein reperfusion, she experienced severe postreperfusion syndrome. Administration of ephedrine and calcium restored arterial pressure; however, pulmonary artery pressure, pulmonary vascular resistance, and central venous pressure elevations were sustained, causing right ventricular overload. This condition did not improve after hepatic artery reperfusion, and caused post-transplant portal hypertension. After nitroglycerin administration, pulmonary vascular resistance and central venous pressure decreased, mean arterial pressure increased, right heart contractility recovered, and portal hypertension disappeared. Hemodynamic improvement by nitroglycerin administration helped in diagnosing postreperfusion syndrome and avoiding unnecessary splenectomy. If portal vein pressure increases after liver transplantation, the change in hemodynamic parameters by nitroglycerin administration should be assessed, which will lead to accurate diagnosis and appropriate treatment. Furthermore, postreperfusion syndrome should be listed as a differential diagnosis of post-transplant portal hypertension.
-
Membranes 12(8) 2022年8月22日Blood purification is performed to control cytokines in critically ill patients. The relationship between the clearance (CL) and the membrane area during adsorption is not clear. We hypothesized that the CL increases with the hydrophobic area when hydrophobic binding contributes to cytokine adsorption. We investigated the relationship between the hemofilter membrane area and the CL of the high mobility group box 1 protein (HMGB-1) and interleukin-6 (IL-6). We performed experimental hemofiltration in vitro using polymethyl methacrylate membranes CH-1.8W (1.8 m2) and CH-1.0N (1.0 m2), as well as polysulfone membrane NV-18X (1.8 m2). After adding 100 mg of HMGB1 or 10 μg of IL-6 into the test solution, experimental hemofiltration was conducted for 360 min in a closed-loop circulation system, and the same amount of HMGB1 and IL-6 was added after 180 min. With CH-1.8W and CH-1.0N, both HMGB-1 and IL-6 showed a rapid concentration decrease of more than 70% at 180 min and 360 min after the re-addition. At 15 min, the CL of HMGB-1 was CH-1.8W: 28.4 and CH-1.0N: 19.8, and that of IL-6 was CH-1.8W: 41.1 and CH-1.0N: 25.4. CH-1.8W and CH-1.0N removed HMGB1 and IL-6 by adsorption and CH-1.8W was superior in CL, which increased with a greater membrane area.
-
International journal of molecular sciences 22(9) 2021年5月6日Neutrophil extracellular trap (NET) formation, an innate immune system response, is associated with thrombogenesis and vascular endothelial injury. Circulatory disorders due to microvascular thrombogenesis are one of the principal causes of organ damage. NET formation in organs contributes to the exacerbation of sepsis, which is defined as a life-threatening organ dysfunction caused by a dysregulated host response to infection. We have previously reported that recombinant human soluble thrombomodulin (rTM) reduces lipopolysaccharide (LPS)-induced NET formation in vitro. Here, we aimed to show that thrombomodulin (TM)-mediated suppression of NET formation protects against organ damage in sepsis. Mice were injected intraperitoneally (i.p.) with 10 mg/kg LPS. rTM (6 mg/kg/day) or saline was administered i.p. 1 h after LPS injection. In the LPS-induced murine septic shock model, extracellular histones, which are components of NETs, were observed in the liver and lungs. In addition, the serum cytokine (interleukin-1β (IL-1β), interleukin-6 (IL-6), tumor necrosis factor-α (TNF-α), macrophage chemotactic protein-1 (MCP-1), and interleukin-10 (IL-10)) levels were increased. The administration of rTM in this model prevented NET formation in the organs and suppressed the increase in the levels of all cytokines except IL-1β. Furthermore, the survival rate improved. We provide a novel role of TM in treating inflammation and NETs in organs during sepsis.
講演・口頭発表等
1所属学協会
8共同研究・競争的資金等の研究課題
1-
日本学術振興会 科学研究費助成事業 2017年4月 - 2020年3月