  • Masahiko Nomura, Yoshiharu Ohno, Yuya Ito, Hirona Kimata, Kenji Fujii, Naruomi Akino, Hiroyuki Nagata, Takahiro Ueda, Takeshi Yoshikawa, Daisuke Takenaka, Yoshiyuki Ozawa
    Journal of computer assisted tomography 2024年11月5日  
    OBJECTIVE: The purpose of this study was to compare radiation dose reduction capability for accurate liver tumor measurements of a computer-aided volumetry (CADv) software for filtered back projection (FBP), hybrid-type iterative reconstruction (IR), mode-based iterative reconstruction (MBIR), and deep learning reconstruction (DLR) at a phantom study. METHODS: A commercially available anthropomorphic abdominal phantom was scanned five times with a 320-detector row CT at 600 mA, 400 mA, 200 mA, and 100 mA and reconstructed by four methods. Signal-to-noise ratios (SNRs) of all lesions within the arterial and portal-venous phase inserts were calculated, and SNR of the lesion phantom was compared with that of all reconstruction methods by means of Tukey's honestly significant difference (HSD) test. Then, tumor volume (V) of each nodule was automatically measured using commercially available CADv software. To compare dose reduction capability for each reconstruction method at both phases, mean differences between measured V and standard references were compared by Tukey's honestly significant difference test among the four different reconstruction methods on CT obtained at each of the four tube currents. RESULTS: With each of the tube currents, SNRs for MBIR and DLR were significantly higher than those for FBP and hybrid-type IR (p < 0.05). At the arterial phase, the mean difference in V for the CT protocol obtained at 600 or 100 mA and reconstructed with DLR was significantly smaller than that for others (p < 0.05). At the portal-venous phase, the mean differences in V for the CT protocol obtained at 100 mA and reconstructed with hybrid-type IR, MBIR, and DLR were significantly smaller than that for FBP (p < 0.05). CONCLUSIONS: Findings of our phantom study show that reconstruction method had influence on CADv merits for abdominal CT with not only standard but also reduced dose examinations and that DLR can potentially yield better image quality and CADv measurements than FBP, hybrid-type IR, or MBIR in this setting.
  • Yoshiharu Ohno, Takahiro Ueda, Masahiko Nomura, Yuichiro Sano, Kaori Yamamoto, Maiko Shinohara, Masato Ikedo, Masao Yui, Akiyoshi Iwase, Hiroyuki Nagata, Takeshi Yoshikawa, Daisuke Takenaka, Akihiro Tomita, Nobuyuki Fujita, Yoshiyuki Ozawa
    Magnetic resonance imaging 110240-110240 2024年9月29日  
    PURPOSE: The purpose of this study was to determine the capability of proton density with fat fraction (PD-FFQ) imaging to help assess hematopoietic ability and diagnose aplastic anemia in adults. METHODS: Between January 2021 and March 2023, patients diagnosed with aplastic anemia (AA: n = 14) or myelodysplastic syndrome (MDS: n = 14) were examined by whole-body PD-FFQ imaging, and 14 of 126 age and gender matched patients who had undergone the same PD-FFQ imaging were selected as control group. All proton density fat fraction (PDFF) index evaluations were then performed by using regions of interest (ROIs). Pearson's correlation was used to determine the relationship between blood test results and each quantitative index, and ROC-based positive test and discrimination analyses to compare capability to differentiate the AA from the non-AA group. Finally, sensitivity, specificity and accuracy of all quantitative indexes were compared by means of McNemar's test. RESULTS: Mean PDFF, standard deviation (SD) and percentage of coefficient of variation (%CV) for vertebrae showed significant correlation with blood test results (-0.52 ≤ r ≤ -0.34, p < 0.05). Specificity (SP) and accuracy (AC) of %CV of PDFF in vertebrae were significantly higher than those of mean PDFF in vertebrae and the posterior superior iliac spine (SP: p = 0.0002, AC: p = 0.0001) and SD of PDFF in vertebrae (SP: p = 0.008, AC: p = 0.008). Moreover, AC of SD of PDFF in vertebrae was significantly higher than that of mean PDFF in vertebrae and the posterior superior iliac spine (p = 0.03). CONCLUSION: Whole-body PD-FFQ imaging is useful for hematopoietic ability assessment and diagnosis of aplastic anemia in adults.
  • Takeshi Yoshikawa, Takahiro Ueda, Yoshiharu Ohno
    Journal of magnetic resonance imaging : JMRI 2024年9月16日  
  • Tomoki Takahashi, Yoshiyuki Ozawa, Hidekazu Hattori, Masahiko Nomura, Takahiro Ueda, Tomoya Horiguchi, Kazuyoshi Imaizumi, Yasushi Matsuda, Yasushi Hoshikawa, Yuka Kondo-Kawabe, Tetsuya Tsukamoto, Hiroyuki Nagata, Yoshiharu Ohno
    Journal of thoracic imaging 2024年9月16日  
  • Takahiro Ueda, Kaori Yamamoto, Natsuka Yazawa, Ikki Tozawa, Masato Ikedo, Masao Yui, Hiroyuki Nagata, Masahiko Nomura, Yoshiyuki Ozawa, Yoshiharu Ohno
    European radiology experimental 8(1) 103-103 2024年9月10日  
    BACKGROUND: We aimed to determine the capabilities of compressed sensing (CS) and deep learning reconstruction (DLR) with those of conventional parallel imaging (PI) for improving image quality while reducing examination time on female pelvic 1.5-T magnetic resonance imaging (MRI). METHODS: Fifty-two consecutive female patients with various pelvic diseases underwent MRI with T1- and T2-weighted sequences using CS and PI. All CS data was reconstructed with and without DLR. Signal-to-noise ratio (SNR) of muscle and contrast-to-noise ratio (CNR) between fat tissue and iliac muscle on T1-weighted images (T1WI) and between myometrium and straight muscle on T2-weighted images (T2WI) were determined through region-of-interest measurements. Overall image quality (OIQ) and diagnostic confidence level (DCL) were evaluated on 5-point scales. SNRs and CNRs were compared using Tukey's test, and qualitative indexes using the Wilcoxon signed-rank test. RESULTS: SNRs of T1WI and T2WI obtained using CS with DLR were higher than those using CS without DLR or conventional PI (p < 0.010). CNRs of T1WI and T2WI obtained using CS with DLR were higher than those using CS without DLR or conventional PI (p < 0.003). OIQ of T1WI and T2WI obtained using CS with DLR were higher than that using CS without DLR or conventional PI (p < 0.001). DCL of T2WI obtained using CS with DLR was higher than that using conventional PI or CS without DLR (p < 0.001). CONCLUSION: CS with DLR provided better image quality and shorter examination time than those obtainable with PI for female pelvic 1.5-T MRI. RELEVANCE STATEMENT: CS with DLR can be considered effective for attaining better image quality and shorter examination time for female pelvic MRI at 1.5 T compared with those obtainable with PI. KEY POINTS: Patients underwent MRI with T1- and T2-weighted sequences using CS and PI. All CS data was reconstructed with and without DLR. CS with DLR allowed for examination times significantly shorter than those of PI and provided significantly higher signal- and CNRs, as well as OIQ.
  • 小澤 良之, 永田 紘之, 植田 高弘, 野村 昌彦, 吉川 武, 竹中 大祐, 大野 良治
    INNERVISION 39(9) 39-42 2024年8月  
    核磁気共鳴画像(magnetic resonance imaging:MRI)は高い組織分解能を有し,胸部におけるその潜在的な臨床的有用性は臨床導入当初から示唆されていたが,1990年代初頭のMR撮像技術レベルでは,肺野末梢構造などを当時のコンピュータ断層撮影(computed tomography:CT)と同様に描出することができなかった。そのため,1991年にThe Fleischner Societyの当時の主要メンバーによって構成された北米放射線学会のRadiologic Diagnostic Oncology Group(RDOG)は,Radiologyに胸部MRIの肺がん診療における有用性が限定されたものであることを示唆し,それ以降,長く胸部疾患への臨床応用は限定された施設や臨床目的に対してのみ行われてきた。その後,30年以上にわたるさまざまなMRI装置,MRIの撮像技術や造影剤の使用などの進歩により,2020年に現在のThe Fleischner Societyの主要メンバーにより呼吸器領域のMRIの臨床的価値は再定義され,積極的な臨床応用が進められている。したがって,2020年代の放射線診断専門医,診療放射線技師および放射線治療専門医などを含めた呼吸器診療に携わる医療従事者にとって,胸部MRIは,胸部CTや核医学検査などと同様に必須の検査法となっている。併せて,さまざまな肺機能イメージング法としての肺機能MRI(pulmonary functional MRI)法の開発が1996年以降で行われており,核医学に代わるその臨床的有用性に関しても徐々に確立されつつある。本稿においては,肺MRIの最新技術とそれらによる臨床evidenceに関して述べる。(著者抄録)
  • Hirotaka Ikeda, Yoshiharu Ohno, Kaori Yamamoto, Kazuhiro Murayama, Masato Ikedo, Masao Yui, Yunosuke Kumazawa, Yurika Shimamura, Yui Takagi, Yuhei Nakagaki, Satomu Hanamatsu, Yuki Obama, Takahiro Ueda, Hiroyuki Nagata, Yoshiyuki Ozawa, Akiyoshi Iwase, Hiroshi Toyama
    Cancers 16(9) 2024年4月28日  
    BACKGROUND: Diffusion-weighted images (DWI) obtained by echo-planar imaging (EPI) are frequently degraded by susceptibility artifacts. It has been suggested that DWI obtained by fast advanced spin-echo (FASE) or reconstructed with deep learning reconstruction (DLR) could be useful for image quality improvements. The purpose of this investigation using in vitro and in vivo studies was to determine the influence of sequence difference and of DLR for DWI on image quality, apparent diffusion coefficient (ADC) evaluation, and differentiation of malignant from benign head and neck tumors. METHODS: For the in vitro study, a DWI phantom was scanned by FASE and EPI sequences and reconstructed with and without DLR. Each ADC within the phantom for each DWI was then assessed and correlated for each measured ADC and standard value by Spearman's rank correlation analysis. For the in vivo study, DWIs obtained by EPI and FASE sequences were also obtained for head and neck tumor patients. Signal-to-noise ratio (SNR) and ADC were then determined based on ROI measurements, while SNR of tumors and ADC were compared between all DWI data sets by means of Tukey's Honest Significant Difference test. RESULTS: For the in vitro study, all correlations between measured ADC and standard reference were significant and excellent (0.92 ≤ ρ ≤ 0.99, p < 0.0001). For the in vivo study, the SNR of FASE with DLR was significantly higher than that of FASE without DLR (p = 0.02), while ADC values for benign and malignant tumors showed significant differences between each sequence with and without DLR (p < 0.05). CONCLUSION: In comparison with EPI sequence, FASE sequence and DLR can improve image quality and distortion of DWIs without significantly influencing ADC measurements or differentiation capability of malignant from benign head and neck tumors.
  • Hiroyuki Nagata, Yoshiharu Ohno, Takeshi Yoshikawa, Kaori Yamamoto, Maiko Shinohara, Masato Ikedo, Masao Yui, Takahiro Matsuyama, Tomoki Takahashi, Shuji Bando, Minami Furuta, Takahiro Ueda, Yoshiyuki Ozawa, Hiroshi Toyama
    Magnetic resonance imaging 2024年2月1日  
    PURPOSE: The purpose of this study was to determine the utility of compressed sensing (CS) with deep learning reconstruction (DLR) for improving spatial resolution, image quality and focal liver lesion detection on high-resolution contrast-enhanced T1-weighted imaging (HR-CE-T1WI) obtained by CS with DLR as compared with conventional CE-T1WI with parallel imaging (PI). METHODS: Seventy-seven participants with focal liver lesions underwent conventional CE-T1WI with PI and HR-CE-T1WI, surgical resection, transarterial chemoembolization, and radiofrequency ablation, followed by histopathological or >2-year follow-up examinations in our hospital. Signal-to-noise ratios (SNRs) of liver, spleen and kidney were calculated for each patient, after which each SNR was compared by means of paired t-test. To compare focal lesion detection capabilities of the two methods, a 5-point visual scoring system was adopted for a per lesion basis analysis. Jackknife free-response receiver operating characteristic (JAFROC) analysis was then performed, while sensitivity and false positive rates (/data set) for consensus assessment of the two methods were also compared by using McNemar's test or the signed rank test. RESULTS: Each SNR of HR-CE-T1WI was significantly higher than that of conventional CE-T1WI with PI (p < 0.05). Sensitivities for consensus assessment showed that HR-CE-MRI had significantly higher sensitivity than conventional CE-T1WI with PI (p = 0.004). Moreover, there were significantly fewer FP/cases for HR-CE-T1WI than for conventional CE-T1WI with PI (p = 0.04). CONCLUSION: CS with DLR are useful for improving spatial resolution, image quality and focal liver lesion detection capability of Gd-EOB-DTPA enhanced 3D T1WI without any need for longer breath-holding time.
  • Minami Furuta, Hirotaka Ikeda, Satomu Hanamatsu, Kaori Yamamoto, Maiko Shinohara, Masato Ikedo, Masao Yui, Hiroyuki Nagata, Masahiko Nomura, Takahiro Ueda, Yoshiyuki Ozawa, Hiroshi Toyama, Yoshiharu Ohno
    European journal of radiology 171 111289-111289 2024年1月6日  
    PURPOSE: The purpose of this in vivo study was to determine the effect of reverse encoding direction (RDC) on apparent diffusion coefficient (ADC) measurements and its efficacy for improving image quality and diagnostic performance for differentiating malignant from benign tumors on head and neck diffusion-weighted imaging (DWI). METHODS: Forty-eight patients with head and neck tumors underwent DWI with and without RDC and pathological examinations. Their tumors were then divided into two groups: malignant (n = 21) and benign (n = 27). To determine the utility of RDC for DWI, the difference in the deformation ratio (DR) between DWI and T2-weighted images of each tumor was determined for each tumor area. To compare ADC measurement accuracy of DWIs with and without RDC for each patient, ADC values for tumors and spinal cord were determined by using ROI measurements. To compare DR and ADC between two methods, Student's t-tests were performed. Then, ADC values were compared between malignant and benign tumors by Student's t-test on each DWI. Finally, sensitivity, specificity and accuracy were compared by means of McNemar's test. RESULTS: DR of DWI with RDC was significantly smaller than that without RDC (p < 0.0001). There were significant differences in ADC between malignant and benign lesions on each DWI (p < 0.05). However, there were no significant difference of diagnostic accuracy between the two DWIs (p > 0.05). CONCLUSION: RDC can improve image quality and distortion of DWI and may have potential for more accurate ADC evaluation and differentiation of malignant from benign head and neck tumors.
  • Yoshiharu Ohno, Yoshiyuki Ozawa, Hiroyuki Nagata, Takahiro Ueda, Takeshi Yoshikawa, Daisuke Takenaka, Hisanobu Koyama
    Investigative radiology 2023年9月15日  
    Since lung magnetic resonance imaging (MRI) became clinically available, limited clinical utility has been suggested for applying MRI to lung diseases. Moreover, clinical applications of MRI for patients with lung diseases or thoracic oncology may vary from country to country due to clinical indications, type of health insurance, or number of MR units available. Because of this situation, members of the Fleischner Society and of the Japanese Society for Magnetic Resonance in Medicine have published new reports to provide appropriate clinical indications for lung MRI. This review article presents a brief history of lung MRI in terms of its technical aspects and major clinical indications, such as (1) what is currently available, (2) what is promising but requires further validation or evaluation, and (3) which developments warrant research-based evaluations in preclinical or patient studies. We hope this article will provide Investigative Radiology readers with further knowledge of the current status of lung MRI and will assist them with the application of appropriate protocols in routine clinical practice.
  • Daisuke Takenaka, Yoshiyuki Ozawa, Kaori Yamamoto, Maiko Shinohara, Masato Ikedo, Masao Yui, Yuka Oshima, Nayu Hamabuchi, Hiroyuki Nagata, Takahiro Ueda, Hirotaka Ikeda, Akiyoshi Iwase, Takeshi Yoshikawa, Hiroshi Toyama, Yoshiharu Ohno
    Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine 2023年9月1日  
    PURPOSE: Deep learning reconstruction (DLR) has been recommended as useful for improving image quality. Moreover, compressed sensing (CS) or DLR has been proposed as useful for improving temporal resolution and image quality on MR sequences in different body fields. However, there have been no reports regarding the utility of DLR for image quality and T-factor assessment improvements on T2-weighted imaging (T2WI), short inversion time (TI) inversion recovery (STIR) imaging, and unenhanced- and contrast-enhanced (CE) 3D fast spoiled gradient echo (GRE) imaging with and without CS in comparison with thin-section multidetector-row CT (MDCT) for non-small cell lung cancer (NSCLC) patients. The purpose of this study was to determine the utility of DLR for improving image quality and the appropriate sequence for T-category assessment for NSCLC patients. METHODS: As subjects for this study, 213 pathologically diagnosed NSCLC patients who underwent thin-section MDCT and MR imaging as well as T-factor diagnosis were retrospectively enrolled. SNR of each tumor was calculated and compared by paired t-test for each sequence with and without DLR. T-factor for each patient was assessed with thin-section MDCT and all MR sequences, and the accuracy for T-factor diagnosis was compared among all sequences and thin-section CT by means of McNemar's test. RESULTS: SNRs of T2WI, STIR imaging, unenhanced thin-section Quick 3D imaging, and CE-thin-section Quick 3D imaging with DLR were significantly higher than SNRs of those without DLR (P < 0.05). Diagnostic accuracy of STIR imaging and CE-thick- or thin-section Quick 3D imaging was significantly higher than that of thin-section CT, T2WI, and unenhanced thick- or thin-section Quick 3D imaging (P < 0.05). CONCLUSION: DLR is thus considered useful for image quality improvement on MR imaging. STIR imaging and CE-Quick 3D imaging with or without CS were validated as appropriate MR sequences for T-factor evaluation in NSCLC patients.
  • Yuka Oshima, Yoshiharu Ohno, Daisuke Takenaka, Yuya Ito, Hirona Kimata, Kenji Fujii, Naruomi Akino, Nayu Hamabuchi, Takahiro Matsuyama, Hiroyuki Nagata, Takahiro Ueda, Hirotaka Ikeda, Yoshiyuki Ozawa, Takeshi Yoshikawa, Hiroshi Toyama
    European journal of radiology 166 110969-110969 2023年9月  
    PURPOSE: To compare the capability of CTs obtained with a silver or copper x-ray beam spectral modulation filter (Ag filter and Cu filter) and reconstructed with FBP, hybrid-type IR and deep learning reconstruction (DLR) for radiation dose reduction for lung nodule detection using a chest phantom study. MATERIALS AND METHODS: A chest CT phantom was scanned with a 320-detector row CT with Ag filter at 0.6, 1.6 and 2.5 mGy and Cu filters at 0.6, 1.6, 2.5 and 9.6 mGy, and reconstructed with the aforementioned methods. To compare image quality of all the CT data, SNRs and CNRs for any nodule were calculated for all protocols. To compare nodule detection capability among all protocols, the probability of detection of any nodule was assessed with a 5-point visual scoring system. Then, ROC analyses were performed to compare nodule detection capability of Ag and Cu filters for each radiation dose data with the same method and of the three methods for any radiation dose data and obtained with either filter. RESULTS: At any of the doses, SNR, CNR and area under the curve for the Ag filter were significantly higher or larger than those for the Cu filter (p < 0.05). Moreover, with DLR, those values were significantly higher or larger than all the others for CTs obtained with any of the radiation doses and either filter (p < 0.05). CONCLUSION: The Ag filter and DLR can significantly improve image quality and nodule detection capability compared with the Cu filter and other reconstruction methods at each of radiation doses used.
  • Yoshiharu Ohno, Masao Yui, Kaori Yamamoto, Masato Ikedo, Yuka Oshima, Nayu Hamabuchi, Satomu Hanamatsu, Hiroyuki Nagata, Takahiro Ueda, Hirotaka Ikeda, Daisuke Takenaka, Takeshi Yoshikawa, Yoshiyuki Ozawa, Hiroshi Toyama
    European radiology 2023年8月15日  
    OBJECTIVE: The purpose of this study was thus to compare capabilities for quantitative differentiation of non- and minimally invasive adenocarcinomas from other of pulmonary MRIs with ultra-short TE (UTE) obtained with single- and dual-echo techniques (UTE-MRISingle and UTE-MRIDual) and thin-section CT for stage IA lung cancer patients. METHODS: Ninety pathologically diagnosed stage IA lung cancer patients who underwent thin-section standard-dose CT, UTE-MRISingle, and UTE-MRIDual, surgical treatment and pathological examinations were included in this retrospective study. The largest dimension (Dlong), solid portion (solid Dlong), and consolidation/tumor (C/T) ratio of each nodule were assessed. Two-tailed Student's t-tests were performed to compare all indexes obtained with each method between non- and minimally invasive adenocarcinomas and other lung cancers. Receiver operating characteristic (ROC)-based positive tests were performed to determine all feasible threshold values for distinguishing non- or minimally invasive adenocarcinoma (MIA) from other lung cancers. Sensitivity, specificity, and accuracy were then compared by means of McNemar's test. RESULTS: Each index showed significant differences between the two groups (p < 0.0001). Specificities and accuracies of solid Dlong for UTE-MRIDual2nd echo and CTMediastinal were significantly higher than those of solid Dlong for UTE-MRISingle and UTE-MRIDual1st echo and all C/T ratios except CTMediastinal (p < 0.05). Moreover, the specificities and accuracies of solid Dlong and C/T ratio were significantly higher than those of Dlong for each method (p < 0.05). CONCLUSION: Pulmonary MRI with UTE is considered at least as valuable as thin-section CT for quantitative differentiation of non- and minimally invasive adenocarcinomas from other stage IA lung cancers. CLINICAL RELEVANCE STATEMENT: Pulmonary MRI with UTE's capability for quantitative differentiation of non- and minimally invasive adenocarcinomas from other lung cancers in stage IA lung cancer patients is equal or superior to that of thin-section CT. KEY POINTS: • Correlations were excellent for pathologically examined nodules with the largest dimensions (Dlong) and a solid component (solid Dlong) for all indexes (0.95 ≤ r ≤ 0.99, p < 0.0001). • Pathologically examined Dlong and solid Dlong obtained with all methods showed significant differences between non- and minimally invasive adenocarcinomas and other lung cancers (p < 0.0001). • Solid tumor components are most accurately measured by UTE-MRIDual2nd echo and CTMediastinal, whereas the ground-glass component is imaged by UTE-MRIDual1st echo and CTlung with high accuracy. UTE-MRIDual predicts tumor invasiveness with 100% sensitivity and 87.5% specificity at a C/T threshold of 0.5.
  • Yoshiharu Ohno, Yoshiyuki Ozawa, Hiroyuki Nagata, Shuji Bando, Shang Cong, Tomoki Takahashi, Yuka Oshima, Nayu Hamabuchi, Takahiro Matsuyama, Takahiro Ueda, Takeshi Yoshikawa, Daisuke Takenaka, Hiroshi Toyama
    Diagnostics (Basel, Switzerland) 13(15) 2023年7月28日  
    An area-detector CT (ADCT) has a 320-detector row and can obtain isotropic volume data without helical scanning within an area of nearly 160 mm. The actual-perfusion CT data within this area can, thus, be obtained by means of continuous dynamic scanning for the qualitative or quantitative evaluation of regional perfusion within nodules, lymph nodes, or tumors. Moreover, this system can obtain CT data with not only helical but also step-and-shoot or wide-volume scanning for body CT imaging. ADCT also has the potential to use dual-energy CT and subtraction CT to enable contrast-enhanced visualization by means of not only iodine but also xenon or krypton for functional evaluations. Therefore, systems using ADCT may be able to function as a pulmonary functional imaging tool. This review is intended to help the reader understand, with study results published during the last a few decades, the basic or clinical evidence about (1) newly applied reconstruction methods for radiation dose reduction for functional ADCT, (2) morphology-based pulmonary functional imaging, (3) pulmonary perfusion evaluation, (4) ventilation assessment, and (5) biomechanical evaluation.
  • Nayu Hamabuchi, Yoshiharu Ohno, Hirona Kimata, Yuya Ito, Kenji Fujii, Naruomi Akino, Daisuke Takenaka, Takeshi Yoshikawa, Yuka Oshima, Takahiro Matsuyama, Hiroyuki Nagata, Takahiro Ueda, Hirotaka Ikeda, Yoshiyuki Ozawa, Hiroshi Toyama
    Japanese journal of radiology 2023年7月27日  
    PURPOSE: Deep learning reconstruction (DLR) has been introduced by major vendors, tested for CT examinations of a variety of organs, and compared with other reconstruction methods. The purpose of this study was to compare the capabilities of DLR for image quality improvement and lung texture evaluation with those of hybrid-type iterative reconstruction (IR) for standard-, reduced- and ultra-low-dose CTs (SDCT, RDCT and ULDCT) obtained with high-definition CT (HDCT) and reconstructed at 0.25-mm, 0.5-mm and 1-mm section thicknesses with 512 × 512 or 1024 × 1024 matrixes for patients with various pulmonary diseases. MATERIALS AND METHODS: Forty age-, gender- and body mass index-matched patients with various pulmonary diseases underwent SDCT (CT dose index volume <CTDIvol>: mean ± standard deviation, 9.0 ± 1.8 mGy), RDCT (CTDIvol: 1.7 ± 0.2 mGy) and ULDCT (CTDIvol: 0.8 ± 0.1 mGy) at a HDCT. All CT data set were then reconstructed with 512 × 512 or 1024 × 1024 matrixes by means of hybrid-type IR and DLR. SNR of lung parenchyma and probabilities of all lung textures were assessed for each CT data set. SNR and detection performance of each lung texture reconstructed with DLR and hybrid-type IR were then compared by means of paired t tests and ROC analyses for all CT data at each section thickness. RESULTS: Data for each radiation dose showed DLR attained significantly higher SNR than hybrid-type IR for each of the CT data (p < 0.0001). On assessments of all findings except consolidation and nodules or masses, areas under the curve (AUCs) for ULDCT with hybrid-type IR for each section thickness (0.91 ≤ AUC ≤ 0.97) were significantly smaller than those with DLR (0.97 ≤ AUC ≤ 1, p < 0.05) and the standard protocol (0.98 ≤ AUC ≤ 1, p < 0.05). CONCLUSION: DLR is potentially more effective for image quality improvement and lung texture evaluation than hybrid-type IR on all radiation dose CTs obtained at HDCT and reconstructed with each section thickness with both matrixes for patients with a variety of pulmonary diseases.
  • Yoshiyuki Ozawa, Yoshiharu Ohno, Hiroyuki Nagata, Keigo Tamokami, Keitaro Nishikimi, Yuka Oshima, Nayu Hamabuchi, Takahiro Matsuyama, Takahiro Ueda, Hiroshi Toyama
    Diagnostics 13(13) 2295-2295 2023年7月6日  
    Dual-energy computed tomography (DECT) can improve the differentiation of material by using two different X-ray energy spectra, and may provide new imaging techniques to diagnostic radiology to overcome the limitations of conventional CT in characterizing tissue. Some techniques have used dual-energy imaging, which mainly includes dual-sourced, rapid kVp switching, dual-layer detectors, and split-filter imaging. In iodine images, images of the lung’s perfused blood volume (PBV) based on DECT have been applied in patients with pulmonary embolism to obtain both images of the PE occluding the pulmonary artery and the consequent perfusion defects in the lung’s parenchyma. PBV images of the lung also have the potential to indicate the severity of PE, including chronic thromboembolic pulmonary hypertension. Virtual monochromatic imaging can improve the accuracy of diagnosing pulmonary vascular diseases by optimizing kiloelectronvolt settings for various purposes. Iodine images also could provide a new approach in the area of thoracic oncology, for example, for the characterization of pulmonary nodules and mediastinal lymph nodes. DECT-based lung ventilation imaging is also available with noble gases with high atomic numbers, such as xenon, which is similar to iodine. A ventilation map of the lung can be used to image various pulmonary diseases such as chronic obstructive pulmonary disease.
  • Takahiro Ueda, Yoshiharu Ohno, Maiko Shinohara, Kaori Yamamoto, Masato Ikedo, Masao Yui, Takeshi Yoshikawa, Daisuke Takenaka, Sayuri Ishida, Minami Furuta, Takahiro Matsuyama, Hiroyuki Nagata, Hirotaka Ikeda, Yoshiyuki Ozawa, Hiroshi Toyama
    European journal of radiology 162 110764-110764 2023年5月  
    PURPOSE: The purpose of this study was to determine the influenceof reverse encoding distortion correction (RDC) on ADC measurement and its efficacy for improving image quality and diagnostic performance for differentiating malignant from benign prostatic areas on prostatic DWI. METHODS: Forty suspected prostatic cancer patients underwent DWI with or without RDC (i.e. RDC DWI or DWI) using a 3 T MR system as well as pathological examinations. The pathological examination results indicated 86 areas were malignant while 86 out of 394 areas were computationally selected as benign. SNR for benign areas and muscle and ADCs for malignant and benign areas were determined by ROI measurements on each DWI. Moreover, overall image quality was assessed with a 5-point visual scoring system on each DWI. Paired t-test or Wilcoxon's signed rank test was performed to compare SNR and overall image quality for DWIs. ROC analysis was then used to compare the diagnostic performance, and sensitivity (SE), specificity (SP) and accuracy (AC) of ADC were compared between two DWI by means of McNemar's test. RESULTS: SNR and overall image quality of RDC DWI showed significant improvements when compared with those of DWI (p < 0.05). Areas under the curve (AUC), SP and AC of DWI RDC DWI (AUC: 0.85, SP: 72.1%, AC: 79.1%) were significantly better than those of DWI (AUC: 0.79, p = 0.008; SP: 64%, p = 0.02; AC: 74.4%, p = 0.008). CONCLUSION: RDC technique has the potential to improve image quality and ability to differentiate malignant from benign prostatic areas on DWIs of suspected prostatic cancer patients.
  • Yoshiharu Ohno, Masao Yui, Kaori Yamamoto, Daisuke Takenaka, Hisanobu Koyama, Hiroyuki Nagata, Takahiro Ueda, Hirotaka Ikeda, Yoshiyuki Ozawa, Hiroshi Toyama, Takeshi Yoshikawa
    Journal of Magnetic Resonance Imaging 58(1) 174-186 2023年3月27日  
    BACKGROUND: Amide proton transfer (APT) weighted chemical exchange saturation transfer CEST (APTw/CEST) magnetic resonance imaging (MRI) has been suggested as having the potential for assessing the therapeutic effect of brain tumors or rectal cancer. Moreover, diffusion-weighted imaging (DWI) and positron emission tomography fused with computed tomography by means of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG-PET/CT) have been suggested as useful in same setting. PURPOSE: To compare the capability of APTw/CEST imaging, DWI, and FDG-PET/CT for predicting therapeutic effect of chemoradiotherapy (CRT) on stage III non-small cell lung cancer (NSCLC) patients. STUDY TYPE: Prospective. POPULATION: Eighty-four consecutive patients with Stage III NSCLC, 45 men (age range, 62-75 years; mean age, 71 years) and 39 women (age range, 57-75 years; mean age, 70 years). All patients were then divided into two groups (Response Evaluation Criteria in Solid Tumors [RECIST] responders, consisting of the complete response and partial response groups, and RECIST non-responders, consisting of the stable disease and progressive disease groups). FIELD STRENGTH/SEQUENCE: 3 T, echo planar imaging or fast advanced spin-echo (FASE) sequences for DWI and 2D half Fourier FASE sequences with magnetization transfer pulses for CEST imaging. ASSESSMENT: Magnetization transfer ratio asymmetry (MTRasym ) at 3.5 ppm, apparent diffusion coefficient (ADC), and maximum standard uptake value (SUVmax, ) on PET/CT were assessed by means of region of interest (ROI) measurements at primary tumor. STATISTICAL TESTS: Kaplan-Meier method followed by log-rank test and Cox proportional hazards regression analysis with multivariate analysis. A P value <0.05 was considered statistically significant. RESULTS: Progression-free survival (PFS) and overall survival (OS) had significant difference between two groups. MTRasym at 3.5 ppm (hazard ratio [HR] = 0.70) and SUVmax (HR = 1.41) were identified as significant predictors for PFS. Tumor staging (HR = 0.57) was also significant predictors for OS. DATA CONCLUSION: APTw/CEST imaging showed potential performance as DWI and FDG-PET/CT for predicting the therapeutic effect of CRT on stage III NSCLC patients. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.
  • Yoshiharu Ohno, Yoshiyuki Ozawa, Hisanobu Koyama, Takeshi Yoshikawa, Daisuke Takenaka, Hiroyuki Nagata, Takahiro Ueda, Hirotaka Ikeda, Hiroshi Toyama
    Cancers 15(3) 950-950 2023年2月2日  
    Since the Radiology Diagnostic Oncology Group (RDOG) report had been published in 1991, magnetic resonance (MR) imaging had limited clinical availability for thoracic malignancy, as well as pulmonary diseases. However, technical advancements in MR systems, such as sequence and reconstruction methods, and adjustments in the clinical protocol for gadolinium contrast media administration have provided fruitful results and validated the utility of MR imaging (MRI) for lung cancer evaluations. These techniques include: (1) contrast-enhanced MR angiography for T-factor evaluation, (2) short-time inversion recovery turbo spin-echo sequences as well as diffusion-weighted imaging (DWI) for N-factor assessment, and (3) whole-body MRI with and without DWI and with positron emission tomography fused with MRI for M-factor or TNM stage evaluation as well as for postoperative recurrence assessment of lung cancer or other thoracic tumors using 1.5 tesla (T) or 3T systems. According to these fruitful results, the Fleischner Society has changed its position to approve of MRI for lung or thoracic diseases. The purpose of this review is to analyze recent advances in lung MRI with a particular focus on lung cancer evaluation, clinical staging, and recurrence assessment evaluation.
  • Yuki Obama, Yoshiharu Ohno, Kaori Yamamoto, Masato Ikedo, Masao Yui, Satomu Hanamatsu, Takahiro Ueda, Hirotaka Ikeda, Kazuhiro Murayama, Hiroshi Toyama
    Magnetic resonance imaging 2022年8月4日  
    PURPOSE: To compare capabilities of compressed sensing (CS) with and without deep learning reconstruction (DLR) with those of conventional parallel imaging (PI) with and without DLR for improving examination time and image quality of shoulder MRI for patients with various shoulder diseases. METHODS AND MATERIALS: Thirty consecutive patients with suspected shoulder diseases underwent MRI at a 3 T MR system using PI and CS. All MR data was reconstructed with and without DLR. For quantitative image quality evaluation, ROI measurements were used to determine signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). For qualitative image quality assessment, two radiologists evaluated overall image quality, artifacts and diagnostic confidence level using a 5-point scoring system, and consensus of the two readers determined each final value. Tukey's HSD test was used to compare examination times to establish the capability of the two techniques for reducing examination time. All indexes for all methods were then compared by means of Tukey's HSD test or Wilcoxon's signed rank test. RESULTS: CS with and without DLR showed significantly shorter examination times than PI with and without DLR (p < 0.05). SNR and CNR of CS or PI with DLR were significantly higher than of those without DLR (p < 0.05). Use of DLR significantly improved overall image quality and artifact incidence of CS and PI (p < 0.05). CONCLUSION: Examination time with CS is shorter than with PI without deterioration of image quality of shoulder MRI. Moreover, DLR is useful for both CS and PI for improvement of image quality on shoulder MRI.
  • Yoshiharu Ohno, Naruomi Akino, Yasuko Fujisawa, Hirona Kimata, Yuya Ito, Kenji Fujii, Yumi Kataoka, Yoshihiro Ida, Yuka Oshima, Nayu Hamabuchi, Chika Shigemura, Ayumi Watanabe, Yuki Obama, Satomu Hanamatsu, Takahiro Ueda, Hirotaka Ikeda, Kazuhiro Murayama, Hiroshi Toyama
    European radiology 33(1) 368-379 2022年7月16日  
    OBJECTIVE: Ultra-high-resolution CT (UHR-CT), which can be applied normal resolution (NR), high-resolution (HR), and super-high-resolution (SHR) modes, has become available as in conjunction with multi-detector CT (MDCT). Moreover, deep learning reconstruction (DLR) method, as well as filtered back projection (FBP), hybrid-type iterative reconstruction (IR), and model-based IR methods, has been clinically used. The purpose of this study was to directly compare lung CT number and airway dimension evaluation capabilities of UHR-CT using different scan modes with those of MDCT with different reconstruction methods as investigated in a lung density and airway phantom design recommended by QIBA. MATERIALS AND METHODS: Lung CT number, inner diameter (ID), inner area (IA), and wall thickness (WT) were measured, and mean differences between measured CT number, ID, IA, WT, and standard reference were compared by means of Tukey's HSD test between all UHR-CT data and MDCT reconstructed with FBP as 1.0-mm section thickness. RESULTS: For each reconstruction method, mean differences in lung CT numbers and all airway parameters on 0.5-mm and 1-mm section thickness CTs obtained with SHR and HR modes showed significant differences with those obtained with the NR mode on UHR-CT and MDCT (p < 0.05). Moreover, the mean differences on all UHR-CTs obtained with SHR, HR, or NR modes were significantly different from those of 1.0-mm section thickness MDCTs reconstructed with FBP (p < 0.05). CONCLUSION: Scan modes and reconstruction methods used for UHR-CT were found to significantly affect lung CT number and airway dimension evaluations as did reconstruction methods used for MDCT. KEY POINTS: • Scan and reconstruction methods used for UHR-CT showed significantly higher CT numbers and smaller airway dimension evaluations as did those for MDCT in a QIBA phantom study (p < 0.05). • Mean differences in lung CT number for 0.25-mm, 0.5-mm, and 1.0-mm section thickness CT images obtained with SHR and HR modes were significantly larger than those for CT images at 1.0-mm section thickness obtained with MDCT and reconstructed with FBP (p < 0.05). • Mean differences in inner diameter (ID), inner area (IA), and wall thickness (WT) measured with SHR and HR modes on 0.5- and 1.0-mm section thickness CT images were significantly smaller than those obtained with NR mode on UHR-CT and MDCT (p < 0.05).
  • Yoshiharu Ohno, Masao Yui, Daisuke Takenaka, Takeshi Yoshikawa, Hisanobu Koyama, Yoshimori Kassai, Kaori Yamamoto, Yuka Oshima, Nayu Hamabuchi, Satomu Hanamatsu, Yuki Obama, Takahiro Ueda, Hirotaka Ikeda, Hidekazu Hattori, Kazuhiro Murayama, Hiroshi Toyama
    Journal of magnetic resonance imaging : JMRI 57(1) 259-272 2022年6月26日  
    BACKGROUND: Computed diffusion-weighted imaging (cDWI) is a mathematical computation technique that generates DWIs for any b-value by using actual DWI (aDWI) data with at least two different b-values and may improve differentiation of metastatic from nonmetastatic lymph nodes. PURPOSE: To determine the appropriate b-value for cDWI to achieve a better diagnostic capability for lymph node staging (N-staging) in non-small cell lung cancer (NSCLC) patients compared to aDWI, short inversion time (TI) inversion recovery (STIR) imaging, or positron emission tomography with 2-[fluorine-18] fluoro-2-deoxy-d-glucose combined with computed tomography (FDG-PET/CT). STUDY TYPE: Prospective. SUBJECTS: A total of 245 (127 males and 118 females; mean age 72 years) consecutive histopathologically confirmed NSCLC patients. FIELD STRENGTH/SEQUENCE: A 3 T, half-Fourier single-shot turbo spin-echo sequence, electrocardiogram (ECG)-triggered STIR fast advanced spin-echo (FASE) sequence with black blood and STIR acquisition and DWI obtained by FASE with b-values of 0 and 1000 sec/mm2 . ASSESSMENT: From aDWIs with b-values of 0 and 1000 (aDWI1000 ) sec/mm2 , cDWI using 400 (cDWI400 ), 600 (cDWI600 ), 800 (cDWI800 ), and 2000 (cDWI2000 ) sec/mm2 were generated. Then, 114 metastatic and 114 nonmetastatic nodes (mediastinal and hilar lymph nodes) were selected and evaluated with a contrast ratio (CR) for each cDWI and aDWI, apparent diffusion coefficient (ADC), lymph node-to-muscle ratio (LMR) on STIR, and maximum standard uptake value (SUVmax ). STATISTICAL TESTS: Receiver operating characteristic curve (ROC) analysis, Youden index, and McNemar's test. RESULTS: Area under the curve (AUC) of CR600 was significantly larger than the CR400 , CR800 , CR2000 , aCR1000 , and SUVmax . Comparison of N-staging accuracy showed that CR600 was significantly higher than CR400 , CR2000 , ADC, aCR1000 , and SUVmax , although there were no significant differences with CR800 (P = 0.99) and LMR (P = 0.99). DATA CONCLUSION: cDWI with b-value at 600 sec/mm2 may have potential to improve N-staging accuracy as compared with aDWI, STIR, and PET/CT. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.
  • Takahiro Matsuyama, Yoshiharu Ohno, Kaori Yamamoto, Masato Ikedo, Masao Yui, Minami Furuta, Reina Fujisawa, Satomu Hanamatsu, Hiroyuki Nagata, Takahiro Ueda, Hirotaka Ikeda, Saki Takeda, Akiyoshi Iwase, Takashi Fukuba, Hokuto Akamatsu, Ryota Hanaoka, Ryoichi Kato, Kazuhiro Murayama, Hiroshi Toyama
    European radiology 2022年6月10日  査読有り
    OBJECTIVE: To compare the utility of deep learning reconstruction (DLR) for improving acquisition time, image quality, and intraductal papillary mucinous neoplasm (IPMN) evaluation for 3D MRCP obtained with parallel imaging (PI), multiple k-space data acquisition for each repetition time (TR) technique (Fast 3D mode multiple: Fast 3Dm) and compressed sensing (CS) with PI. MATERIALS AND METHODS: A total of 32 IPMN patients who had undergone 3D MRCPs obtained with PI, Fast 3Dm, and CS with PI and reconstructed with and without DLR were retrospectively included in this study. Acquisition time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) obtained with all protocols were compared using Tukey's HSD test. Results of endoscopic ultrasound, ERCP, surgery, or pathological examination were determined as standard reference, and distribution classifications were compared among all 3D MRCP protocols by McNemar's test. RESULTS: Acquisition times of Fast 3Dm and CS with PI with and without DLR were significantly shorter than those of PI with and without DLR (p < 0.05). Each MRCP sequence with DLR showed significantly higher SNRs and CNRs than those without DLR (p < 0.05). IPMN distribution accuracy of PI with and without DLR and Fast 3Dm with DLR was significantly higher than that of Fast 3Dm without DLR and CS with PI without DLR (p < 0.05). CONCLUSION: DLR is useful for improving image quality and IPMN evaluation capability on 3D MRCP obtained with PI, Fast 3Dm, or CS with PI. Moreover, Fast 3Dm and CS with PI may play as substitution to PI for MRCP in patients with IPMN. KEY POINTS: • Mean examination times of multiple k-space data acquisitions for each TR and compressed sensing with parallel imaging were significantly shorter than that of parallel imaging (p < 0.0001). • When comparing image quality of 3D MRCPs with and without deep learning reconstruction, deep learning reconstruction significantly improved signal-to-noise ratio and contrast-to-noise ratio (p < 0.05). • IPMN distribution accuracies of parallel imaging with and without deep learning reconstruction (with vs. without: 88.0% vs. 88.0%) and multiple k-space data acquisitions for each TR with deep learning reconstruction (86.0%) were significantly higher than those of others (p < 0.05).
  • Takahiro Ueda, Yoshiharu Ohno, Kaori Yamamoto, Kazuhiro Murayama, Masato Ikedo, Masao Yui, Satomu Hanamatsu, Yumi Tanaka, Yuki Obama, Hirotaka Ikeda, Hiroshi Toyama
    Radiology 204097-204097 2022年2月1日  査読有り
    Background Deep learning reconstruction (DLR) may improve image quality. However, its impact on diffusion-weighted imaging (DWI) of the prostate has yet to be assessed. Purpose To determine whether DLR can improve image quality of diffusion-weighted MRI at b values ranging from 1000 sec/mm2 to 5000 sec/mm2 in patients with prostate cancer. Materials and Methods In this retrospective study, images of the prostate obtained at DWI with a b value of 0 sec/mm2, DWI with a b value of 1000 sec/mm2 (DWI1000), DWI with a b value of 3000 sec/mm2 (DWI3000), and DWI with a b value of 5000 sec/mm2 (DWI5000) from consecutive patients with biopsy-proven cancer from January to June 2020 were reconstructed with and without DLR. Image quality was assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) from region-of-interest analysis and qualitatively assessed using a five-point visual scoring system (1 [very poor] to 5 [excellent]) for each high-b-value DWI sequence with and without DLR. The SNR, CNR, and visual score for DWI with and without DLR were compared with the paired t test and the Wilcoxon signed rank test with Bonferroni correction, respectively. Apparent diffusion coefficients (ADCs) from DWI with and without DLR were also compared with the paired t test with Bonferroni correction. Results A total of 60 patients (mean age, 67 years; age range, 49-79 years) were analyzed. DWI with DLR showed significantly higher SNRs and CNRs than DWI without DLR (P < .001); for example, with DWI1000 the mean SNR was 38.7 ± 0.6 versus 17.8 ± 0.6, respectively (P < .001), and the mean CNR was 18.4 ± 5.6 versus 7.4 ± 5.6, respectively (P < .001). DWI with DLR also demonstrated higher qualitative image quality than DWI without DLR (mean score: 4.8 ± 0.4 vs 4.0 ± 0.7, respectively, with DWI1000 [P = .001], 3.8 ± 0.7 vs 3.0 ± 0.8 with DWI3000 [P = .002], and 3.1 ± 0.8 vs 2.0 ± 0.9 with DWI5000 [P < .001]). ADCs derived with and without DLR did not differ substantially (P > .99). Conclusion Deep learning reconstruction improves the image quality of diffusion-weighted MRI scans of prostate cancer with no impact on apparent diffusion coefficient quantitation with a 3.0-T MRI system. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Turkbey in this issue.
  • Yoshiharu Ohno, Daisuke Takenaka, Takeshi Yoshikawa, Masao Yui, Hisanobu Koyama, Kaori Yamamoto, Nayu Hamabuchi, Chika Shigemura, Ayumi Watanabe, Takahiro Ueda, Hirotaka Ikeda, Hidekazu Hattori, Kazuhiro Murayama, Hiroshi Toyama
    Radiology 211254-211254 2021年11月30日  査読有り
    Background Pulmonary MRI with ultrashort echo time (UTE) has been compared with chest CT for nodule detection and classification. However, direct comparisons of these methods' capabilities for Lung CT Screening Reporting and Data System (Lung-RADS) evaluation remain lacking. Purpose To compare the capabilities of pulmonary MRI with UTE with those of standard- or low-dose thin-section CT for Lung-RADS classification. Materials and Methods In this prospective study, standard- and low-dose chest CT (270 mA and 60 mA, respectively) and MRI with UTE were used to examine consecutive participants enrolled between January 2017 and December 2020 who met American College of Radiology Appropriateness Criteria for lung cancer screening with low-dose CT. Probability of nodule presence was assessed for all methods with a five-point visual scoring system by two board-certified radiologists. All nodules were then evaluated in terms of their Lung-RADS classification using each method. To compare nodule detection capability of the three methods, consensus for performances was rated by using jackknife free-response receiver operating characteristic analysis, and sensitivity was compared by means of the McNemar test. In addition, weighted κ statistics were used to determine the agreement between Lung-RADS classification obtained with each method and the reference standard generated from standard-dose CT evaluated by two radiologists who were not included in the image analysis session. Results A total of 205 participants (mean age: 64 years ± 7 [standard deviation], 106 men) with 1073 nodules were enrolled. Figure of merit (FOM) (P < .001) had significant differences among three modalities (standard-dose CT: FOM = 0.91, low-dose CT: FOM = 0.89, pulmonary MRI with UTE: FOM = 0.94), with no evidence of false-positive findings in participants with all modalities (P > .05). Agreements for Lung-RADS classification between all modalities and the reference standard were almost perfect (standard-dose CT: κ = 0.82, P < .001; low-dose CT: κ = 0.82, P < .001; pulmonary MRI with UTE: κ = 0.82, P < .001). Conclusion In a lung cancer screening population, ultrashort echo time pulmonary MRI was comparable to standard- or low-dose CT for Lung CT Screening Reporting and Data System classification. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.
  • Yoshiharu Ohno, Kota Aoyagi, Daisuke Takenaka, Takeshi Yoshikawa, Yasuko Fujisawa, Naoki Sugihara, Nayu Hamabuchi, Satomu Hanamatsu, Yuki Obama, Takahiro Ueda, Hidekazu Hattori, Kazuhiro Murayama, Hiroshi Toyama
    Acta radiologica (Stockholm, Sweden : 1987) 63(10) 2841851211044973-2841851211044973 2021年10月12日  査読有り
    BACKGROUND: The need for quantitative assessment of interstitial lung involvement on thin-section computed tomography (CT) has arisen in interstitial lung diseases including connective tissue disease (CTD). PURPOSE: To evaluate the capability of machine learning (ML)-based CT texture analysis for disease severity and treatment response assessments in comparison with qualitatively assessed thin-section CT for patients with CTD. MATERIAL AND METHODS: A total of 149 patients with CTD-related ILD (CTD-ILD) underwent initial and follow-up CT scans (total 364 paired serial CT examinations), pulmonary function tests, and serum KL-6 level tests. Based on all follow-up examination results, all paired serial CT examinations were assessed as "Stable" (n = 188), "Worse" (n = 98) and "Improved" (n = 78). Next, quantitative index changes were determined by software, and qualitative disease severity scores were assessed by consensus of two radiologists. To evaluate differences in each quantitative index as well as in disease severity score between paired serial CT examinations, Tukey's honestly significant difference (HSD) test was performed among the three statuses. Stepwise regression analyses were performed to determine changes in each pulmonary functional parameter and all quantitative indexes between paired serial CT scans. RESULTS: Δ% normal lung, Δ% consolidation, Δ% ground glass opacity, Δ% reticulation, and Δdisease severity score showed significant differences among the three statuses (P < 0.05). All differences in pulmonary functional parameters were significantly affected by Δ% normal lung, Δ% reticulation, and Δ% honeycomb (0.16 ≤r2 ≤0.42; P < 0.05). CONCLUSION: ML-based CT texture analysis has better potential than qualitatively assessed thin-section CT for disease severity assessment and treatment response evaluation for CTD-ILD.
  • Yumi Tanaka, Yoshiharu Ohno, Satomu Hanamatsu, Yuki Obama, Takahiro Ueda, Hirotaka Ikeda, Akiyoshi Iwase, Takashi Fukuba, Hidekazu Hattori, Kazuhiro Murayama, Takeshi Yoshikawa, Daisuke Takenaka, Hisanobu Koyama, Hiroshi Toyama
    Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine 2021年4月29日  査読有り
    Since thoracic MR imaging was first used in a clinical setting, it has been suggested that MR imaging has limited clinical utility for thoracic diseases, especially lung diseases, in comparison with x-ray CT and positron emission tomography (PET)/CT. However, in many countries and states and for specific indications, MR imaging has recently become practicable. In addition, recently developed pulmonary MR imaging with ultra-short TE (UTE) and zero TE (ZTE) has enhanced the utility of MR imaging for thoracic diseases in routine clinical practice. Furthermore, MR imaging has been introduced as being capable of assessing pulmonary function. It should be borne in mind, however, that these applications have so far been academically and clinically used only for healthy volunteers, but not for patients with various pulmonary diseases in Japan or other countries. In 2020, the Fleischner Society published a new report, which provides consensus expert opinions regarding appropriate clinical indications of pulmonary MR imaging for not only oncologic but also pulmonary diseases. This review article presents a brief history of MR imaging for thoracic diseases regarding its technical aspects and major clinical indications in Japan 1) in terms of what is currently available, 2) promising but requiring further validation or evaluation, and 3) developments warranting research investigations in preclinical or patient studies. State-of-the-art MR imaging can non-invasively visualize lung structural and functional abnormalities without ionizing radiation and thus provide an alternative to CT. MR imaging is considered as a tool for providing unique information. Moreover, prospective, randomized, and multi-center trials should be conducted to directly compare MR imaging with conventional methods to determine whether the former has equal or superior clinical relevance. The results of these trials together with continued improvements are expected to update or modify recommendations for the use of MRI in near future.
  • Yoshiharu Ohno, Satomu Hanamatsu, Yuki Obama, Takahiro Ueda, Hirotaka Ikeda, Hidekazu Hattori, Kazuhiro Murayama, Hiroshi Toyama
    The British journal of radiology 20201053-20201053 2021年2月2日  査読有り
    Morphological evaluation of the lung is important in the clinical evaluation of pulmonary diseases. However, the disease process, especially in its early phases, may primarily result in changes in pulmonary function without changing the pulmonary structure. In such cases, the traditional imaging approaches to pulmonary morphology may not provide sufficient insight into the underlying pathophysiology. Pulmonary imaging community has therefore tried to assess pulmonary diseases and functions utilizing not only nuclear medicine, but also CT and MR imaging with various technical approaches. In this review, we overview state-of-the art MR methods and the future direction of: (1) ventilation imaging, (2) perfusion imaging and (3) biomechanical evaluation for pulmonary functional imaging.
  • Takahiro Ueda, Yoshiharu Ohno, Kaori Yamamoto, Akiyoshi Iwase, Takashi Fukuba, Satomu Hanamatsu, Yuki Obama, Hirotaka Ikeda, Masato Ikedo, Masao Yui, Kazuhiro Murayama, Hiroshi Toyama
    European journal of radiology 134 109430-109430 2021年1月  査読有り筆頭著者
    PURPOSE: To demonstrate the utility of compressed sensing with parallel imaging (Compressed SPEEDER) and AiCE compared with that of conventional parallel imaging (SPEEDER) for shortening examination time and improving image quality of women's pelvic MRI. METHOD: Thirty consecutive patients with women's pelvic diseases (mean age 50 years) underwent T2-weighted imaging using Compressed SPEEDER as well as conventional SPEEDER reconstructed with and without AiCE. The examination times were recorded, and signal-to-noise ratio (SNR) was calculated for every patient. Moreover, overall image quality was assessed using a 5-point scoring system, and final scores for all patients were determined by consensus of two readers. Mean examination time, SNR and overall image quality were compared among the four data sets by Wilcoxon signed-rank test. RESULTS: Examination times for Compressed SPEEDER with and without AiCE were significantly shorter than those for conventional SPEEDER with and without AiCE (with AiCE: p < 0.0001, without AiCE: p < 0.0001). SNR of Compressed SPEEDER and of SPEEDER with AiCE was significantly superior to that of Compressed SPEEDER without AiCE (vs. Compressed SPEEDER, p = 0.01; vs. SPEEDER, p = 0.009). Overall image quality of Compressed SPEEDER with AiCE and of SPEEDER with and without AiCE was significantly higher than that of Compressed SPEEDER without AiCE (vs. Compressed SPEEDER with AiCE, p < 0.0001; vs. SPEEDER with AiCE, p < 0.0001; SPEEDER without AiCE, p = 0.0003). CONCLUSION: Image quality and shorten examination time for T2-weighted imaging in women's pelvic MRI can be significantly improved by using Compressed SPEEDER with AiCE in comparison with conventional SPEEDER, although other sequences were not tested.
  • Yoshizawa H, Kawai S, Hirota Y, Ueda T, Kuroda M, Fujii T
    The journal of obstetrics and gynaecology research 45(2) 482-486 2018年10月  査読有り
  • Kawai S, Ichikawa R, Ueda T, Urano M, Kuroda M, Fujii T
    Fujita Medical Journal 2(4) 77-79 2016年11月  査読有り
    <p>  Ovarian cancer arising from an ovarian endometriotic cyst is frequently encountered; however, this condition has rarely been reported in young patients. We herein report a case of malignant transformation of an ovarian endometriotic cyst in a 26-year-old woman (gravida 0, para 0). During the initial examination at our hospital, ultrasound revealed an endometriotic cyst in the right ovary measuring 49×44×29 mm and an endometriotic cyst in the left ovary measuring 59×53×32 mm with no marked mural nodules on either side.<br> The patient was followed up every 3 months while receiving hormone therapy. At the 6-month follow-up, ultrasound revealed 10-mm mural nodules within the endometriotic cyst of the left ovary. At 10 months, ultrasound revealed that these the mural nodules had enlarged to 15 mm. Pelvic magnetic resonance imaging revealed that the tumor in the left ovary was 64×63 mm in size, which was slightly larger than in the previous scan. The patient underwent laparotomy because of the potential for malignant transformation. Pathological examination revealed clear cell adenocarcinoma. Although malignant transformation of this cancer is rare in women in their 20s, its possibility should be considered; this is true even when cyst enlargement can be controlled during hormone therapy. Magnetic resonance imaging is extremely useful in the diagnosis of malignant transformation.</p>
  • Ueda T, Murayama K, Nishizawa H, Fujii T, Toyama H
    Fujita Medical Journal 2(3) 45-50 2016年8月  査読有り筆頭著者
    <p>Objectives: The objective of this study was to identify the correlation between preoperative magnetic resonance imaging (MRI) findings of myoma and the incidence of bleeding during laparoscopic myomectomy (LM).</p><p>Methods: We investigated the preoperative MRI findings of 25 patients who underwent LM from January 2012 to December 2014, including patients who had undergone myoma resection. We evaluated the correlations between perioperative blood loss and the size of the myoma as well as between perioperative blood loss and the maximal minor axis of flow void (MMAFV) of the myoma margins.</p><p>Results: The mean diameters of the myomas were as follows: longest axis, 60.4 ± 20.6 mm; occipitofrontal diameter, 55.0 ± 15.7 mm; upper and lower diameters (ULDs), 53.7 ± 19.3 mm; and transverse diameter, 56.5 ± 21.7 mm. The mean MMAFV was 2.1± 0.9 mm. The estimated mean blood loss was 104.9 g (range, 5–450 g). All myoma diameters showed a significant linear positive correlation with the estimated perioperative blood loss. The correlation of the ULDs was the highest among all myoma diameters (r = 0.59, P = 0.0021). The MMAFV showed a significant linear positive correlation with the estimated perioperative blood loss (r = 0.62, P = 0.0010).</p><p>Conclusions: Our results suggest that the ULDs and MMAFV of the myoma margins are risk factors for bleeding during LM, as determined using preoperative MRI.</p>