医療科学部
Profile Information
- Affiliation
- School of Health Sciences Faculty of Radiological Technology, Fujita Health University
- Degree
- 博士(保健学)(金沢大学)博士(医学)(藤田保健衛生大学)
- J-GLOBAL ID
- 201501015630860117
- researchmap Member ID
- 7000013219
- External link
Research Interests
4Research Areas
1Research History
3-
Apr, 2022 - Present
-
Apr, 2014 - Mar, 2022
-
Apr, 2004 - Mar, 2013
Education
3-
- Sep, 2015
-
Apr, 2005 - Sep, 2012
-
Apr, 2002 - Mar, 2004
Committee Memberships
4-
Apr, 2019 - Present
-
Feb, 2016 - Present
-
Apr, 2019 - Apr, 2023
-
Apr, 2015 - Mar, 2020
Awards
8-
2018
-
2014
Papers
73-
Radiation protection dosimetry, Mar 14, 2024This study aimed to assess fetal radiation exposure in pregnant women undergoing computed tomography (CT) and rotational angiography (RA) examinations for the diagnosis of pelvic trauma. In addition, this study aimed to compare the dose distributions between the two examinations. Surface and average fetal doses were estimated during CT and RA examinations using a pregnant phantom model and real-time dosemeters. The pregnant model phantom was constructed using an anthropomorphic phantom, and a custom-made abdominal phantom was used to simulate pregnancy. The total average fetal dose received by pregnant women from both CT scans (plain, arterial and equilibrium phases) and a single RA examination was ~60 mGy. Because unnecessary repetition of radiographic examinations, such as CT or conventional 2D angiography can increase the radiation risk, the irradiation range should be limited, if necessary, to reduce overall radiation exposure.
-
Dysphagia, Jan 21, 2024This study evaluated the validity of pharyngeal 2D area measurements acquired from the lateral view for predicting the actual 3D volume in healthy adults during swallowing. Seventy-five healthy adults (39 females, 36 males; mean age 51.3 years) were examined using 320-row area detector computed tomography (320-ADCT). All participants swallowed a 10 mL honey-thick barium bolus upon command while seated in a 45° semi-reclining position. Multi-planar reconstruction images and dynamic 3D-CT images were obtained using Aquilion ONE software. Pharyngeal 2D area and 3D volume measurements were taken before swallowing and at the frame depicting maximum pharyngeal constriction. Pharyngeal volume before swallowing (PVhold) was accurately predicted by 2D area (R2 = 0.816). Adding height and sex to the model increased R2 to 0.836. Regarding pharyngeal volume during maximum constriction (PVmax), 2D area also exhibited acceptable predictive power (R2 = 0.777). However, analysis of statistical residuals and outliers revealed a greater tendency for prediction errors when there is less complete constriction of the pharynx as well as asymmetry in bolus flow or movement. Findings highlight the importance of routinely incorporating anterior-posterior views during VFSS exams. Future work is needed to determine clinical utility of pharyngeal volume measurements derived from 320-ADCT.
-
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB), 118 103215-103215, Jan 14, 2024PURPOSE: Organ dose evaluation is important for optimizing cone beam computed tomography (CBCT) scan protocols. However, an evaluation method for various CBCT scanners is yet to be established. In this study, we developed scanner-independent conversion coefficients to estimate organ doses using appropriate peak dose (f(0)) indices. METHODS: This study included various scanners (angiography scanners and linear accelerators) and protocols for the head and body (thorax, abdomen, and pelvis) scan regions. f(0) was measured at five conventional positions (center position (f(0)c) and four peripheral positions (f(0)p) at 90° intervals) in the CT dose index (CTDI) phantom. To identify appropriate measurement positions for organ dose estimation, various f(0) indices were considered. Organ doses were measured by using optically stimulated luminescence dosimeters positioned in an anthropomorphic phantom. Thereafter, the conversion coefficients were calculated from each obtained f(0) value and organ or tissue dose using a linear fit for all scanners, and the coefficient of variation (CV) of the conversion coefficients was calculated for each organ or tissue. The f(0) index with the minimum CV value was proposed as the appropriate index. RESULTS: The appropriate f(0) index was determined as f(0)c for the body region and a maximum of four f(0)p values for the head region. Using the proposed conversion coefficients based on the appropriate f(0) index, the organ/tissue doses were well estimated with a mean error of 14.2% across all scanners and scan regions. CONCLUSIONS: The proposed scanner-independent coefficients are useful for organ dose evaluation using CBCT scanners.
-
Journal of Applied Clinical Medical Physics, Dec 22, 2022
Misc.
45Presentations
193Teaching Experience
14Professional Memberships
5Research Projects
9-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2022 - Mar, 2025
-
科学研究費助成事業, 日本学術振興会, Apr, 2023 - Mar, 2025
-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2019 - Mar, 2021
-
Grants-in-Aid for Scientific Research Grant-in-Aid for Young Scientists (B), Japan Society for the Promotion of Science, Apr, 2016 - Mar, 2019
-
受託研究, 株式会社A-LINE, Oct, 2018 - Feb, 2019