研究者業績

安井 啓祐

ヤスイ ケイスケ  (yasui keisuke)

基本情報

所属
藤田医科大学 医療科学部 放射線学科 講師
学位
博士(医療技術学)(名古屋大学)

研究者番号
50804514
J-GLOBAL ID
201701009374019765
researchmap会員ID
7000020008

外部リンク

論文

 31
  • Keisuke Yasui, Miuna Hayashi, Shiryu Otsuka, Toshiyuki Toshito, Chihiro Omachi, Masaya Ichihara, Riki Oshika, Yuki Tominaga, Hiromi Baba, Hidetoshi Shimizu, Naoki Hayashi
    Medical Physics 2025年3月29日  査読有り筆頭著者責任著者
    Abstract Background Accurate dosimetry is important in radiotherapy, and all equipment used for radiotherapy shoud be audited by an independent external dose audit. Radiophotoluminescence glass dosimeter (RPLD) has excellent characteristics and is widely used for postal dose audit; however, postal dose audit for proton therapy using RPLD has not been established. Purpose This study aims to develop a postal dose audit procedure for scanning proton beams using RPLD, estimate uncertainties, and conduct a multicenter pilot study to validate the methodology. Methods A postal toolkit was developed and a postal dose audit procedure for RPLD measurements of scanning proton beams was established in cooperation with several facilities that employ various accelerators, irradiation equipment, and treatment planning systems (TPS) for clinical use. Based on basic and previous studies, an uncertainty budget was developed for estimating relative uncertainty and pilot studies were conducted at each site. A method for postal dose audits was developed in a multicenter collaboration to develop an approach suitable for implementation across multiple facilities. Results The relative response of 60 RPLDs for scanning proton beam examined in this study was 1.00 ± 1.28% mean ± standard deviation. The combined relative standard uncertainty of postal dosimetry for scanning proton beams using the RPLD was 2.97% (k = 1). Under the reference condition, the maximum differences between the ionization chamber measurement (IC) and TPS, RPLD and TPS, and RPLD and IC were 0.97, 1.88, and 2.12%, respectively. The maximum differences between the RPLD and ionization chamber for plateau measurements at 3 cm depth using single‐energy and non‐reference conditions were 11.31 and 4.02%, respectively. Conclusion We established a procedure for the postal dose audits of proton beams using RPLD and presented the results of a multicenter pilot study. By standardizing the reference conditions, the dosimetry uncertainty was estimated at 2.92%. The results demonstrated the feasibility of performing an independent third‐party dose audit of scanning proton beams using RPLD, and for such postal dose audits for proton beams, the irradiation conditions should be standardized to reduce uncertainties. These results are expected to contribute to the development of proton beams.
  • Noriyuki Kadoya, Kazuhiro Arai, Shohei Tanaka, Yuto Kimura, Ryota Tozuka, Keisuke Yasui, Naoki Hayashi, Yoshiyuki Katsuta, Haruna Takahashi, Koki Inoue, Keiichi Jingu
    Radiological physics and technology 2024年9月10日  査読有り
    This study aimed to evaluate the performance for answering the Japanese medical physicist examination and providing the benchmark of knowledge about medical physics in language-generative AI with large language model. We used questions from Japan's 2018, 2019, 2020, 2021 and 2022 medical physicist board examinations, which covered various question types, including multiple-choice questions, and mainly focused on general medicine and medical physics. ChatGPT-3.5 and ChatGPT-4.0 (OpenAI) were used. We compared the AI-based answers with the correct ones. The average accuracy rates were 42.2 ± 2.5% (ChatGPT-3.5) and 72.7 ± 2.6% (ChatGPT-4), showing that ChatGPT-4 was more accurate than ChatGPT-3.5 [all categories (except for radiation-related laws and recommendations/medical ethics): p value < 0.05]. Even with the ChatGPT model with higher accuracy, the accuracy rates were less than 60% in two categories; radiation metrology (55.6%), and radiation-related laws and recommendations/medical ethics (40.0%). These data provide the benchmark for knowledge about medical physics in ChatGPT and can be utilized as basic data for the development of various medical physics tools using ChatGPT (e.g., radiation therapy support tools with Japanese input).
  • Yuya Nagake, Keisuke Yasui, Hiromu Ooe, Masaya Ichihara, Kaito Iwase, Toshiyuki Toshito, Naoki Hayashi
    Radiological Physics and Technology 2024年1月23日  査読有り責任著者
  • Natsuo Tomita, Naoki Hayashi, Tomoki Mizuno, Yuto Kitagawa, Keisuke Yasui, Yasunori Saito, Shuo Sudo, Seiya Takano, Nozomi Kita, Akira Torii, Masanari Niwa, Dai Okazaki, Taiki Takaoka, Daisuke Kawakita, Shinichi Iwasaki, Akio Hiwatashi
    Technical Innovations &amp; Patient Support in Radiation Oncology 28 100221-100221 2023年12月  査読有り
  • Shuta Ogawa, Keisuke Yasui, Naoki Hayashi, Yasunori Saito, Shinya Hayashi
    Cureus 15(10) e48041 2023年10月  査読有り
    Background This study evaluates dose perturbations caused by nonradioactive seeds in clinical cases by employing treatment planning system-based Monte Carlo (TPS-MC) simulation. Methodology We investigated dose perturbation using a water-equivalent phantom and 20 clinical cases of prostate cancer (10 cases with seeds and 10 cases without seeds) treated at Fujita Health University Hospital, Japan. First, dose calculations for a simple geometry were performed using the RayStation MC algorithm for a water-equivalent phantom with and without a seed. TPS-independent Monte Carlo (full-MC) simulations and film measurements were conducted to verify the accuracy of TPS-MC simulation. Subsequently, dose calculations using TPS-MC were performed on CT images of clinical cases of prostate cancer with and without seeds, and the dose distributions were compared. Results In clinical cases, dose calculations using MC simulations revealed hotspots around the seeds. However, the size of the hotspot was not correlated with the number of seeds. The maximum difference in dose perturbation between TPS-MC simulations and film measurements was 3.9%, whereas that between TPS-MC simulations and full-MC simulations was 3.7%. The dose error of TPS-MC was negligible for multiple beams or rotational irradiation. Conclusions Hotspots were observed in dose calculations using TPS-MC performed on CT images of clinical cases with seeds. The dose calculation accuracy around the seeds using TPS-MC simulations was comparable to that of film measurements and full-MC simulations, with differences within 3.9%. Although the clinical impact of hotspots occurring around the seeds is minimal, utilizing MC simulations on TPSs can be beneficial to verify their presence.

MISC

 45

書籍等出版物

 2

講演・口頭発表等

 41

担当経験のある科目(授業)

 22

共同研究・競争的資金等の研究課題

 11

その他

 2
  • 放射線線量率に対する細胞生存率計測のための多様な種類の細胞 *本研究ニーズに関する産学共同研究の問い合わせは藤田医科大学産学連携推進セン ター(fuji-san@fujita-hu.ac.jp)まで
  • 放射線線量計測における検出器の応答特性検証技術 ガラス線量計、半導体検出器等で検証を実施 (Yasui et al; Physica Medica 81 147-154 2021年1月, IJRR 19((2)) 281-289 2021年4月, Nagata et al; JACMP 22(8) 265-272 2021年8月) *本研究ニーズに関する産学共同研究の問い合わせは藤田医科大学産学連携推進セン ター(fuji-san@fujita-hu.ac.jp)まで