医学物理学分野

yasui keisuke

  (安井 啓祐)

Profile Information

Affiliation
Senior Assistant Professor, School of Health Sciences Faculty of Radiological Technology, Fujita Health University
Degree
博士(医療技術学)(名古屋大学)

Researcher number
50804514
J-GLOBAL ID
201701009374019765
researchmap Member ID
7000020008

External link

Research Areas

 1

Papers

 31
  • Yuya Nagake, Keisuke Yasui, Hiromu Ooe, Masaya Ichihara, Kaito Iwase, Toshiyuki Toshito, Naoki Hayashi
    Radiological Physics and Technology, Jan 23, 2024  Peer-reviewedCorresponding author
  • Natsuo Tomita, Naoki Hayashi, Tomoki Mizuno, Yuto Kitagawa, Keisuke Yasui, Yasunori Saito, Shuo Sudo, Seiya Takano, Nozomi Kita, Akira Torii, Masanari Niwa, Dai Okazaki, Taiki Takaoka, Daisuke Kawakita, Shinichi Iwasaki, Akio Hiwatashi
    Technical Innovations & Patient Support in Radiation Oncology, 28 100221-100221, Dec, 2023  Peer-reviewed
  • Shuta Ogawa, Keisuke Yasui, Naoki Hayashi, Yasunori Saito, Shinya Hayashi
    Cureus, 15(10) e48041, Oct, 2023  Peer-reviewed
    Background This study evaluates dose perturbations caused by nonradioactive seeds in clinical cases by employing treatment planning system-based Monte Carlo (TPS-MC) simulation. Methodology We investigated dose perturbation using a water-equivalent phantom and 20 clinical cases of prostate cancer (10 cases with seeds and 10 cases without seeds) treated at Fujita Health University Hospital, Japan. First, dose calculations for a simple geometry were performed using the RayStation MC algorithm for a water-equivalent phantom with and without a seed. TPS-independent Monte Carlo (full-MC) simulations and film measurements were conducted to verify the accuracy of TPS-MC simulation. Subsequently, dose calculations using TPS-MC were performed on CT images of clinical cases of prostate cancer with and without seeds, and the dose distributions were compared. Results In clinical cases, dose calculations using MC simulations revealed hotspots around the seeds. However, the size of the hotspot was not correlated with the number of seeds. The maximum difference in dose perturbation between TPS-MC simulations and film measurements was 3.9%, whereas that between TPS-MC simulations and full-MC simulations was 3.7%. The dose error of TPS-MC was negligible for multiple beams or rotational irradiation. Conclusions Hotspots were observed in dose calculations using TPS-MC performed on CT images of clinical cases with seeds. The dose calculation accuracy around the seeds using TPS-MC simulations was comparable to that of film measurements and full-MC simulations, with differences within 3.9%. Although the clinical impact of hotspots occurring around the seeds is minimal, utilizing MC simulations on TPSs can be beneficial to verify their presence.
  • Keisuke Yasui, Yasunori Saito, Azumi Ito, Momoka Douwaki, Shuta Ogawa, Yuri Kasugai, Hiromu Ooe, Yuya Nagake, Naoki Hayashi
    Scientific reports, 13(1) 15413-15413, Sep 18, 2023  Peer-reviewedLead authorCorresponding author
    Deep learning-based CT image reconstruction (DLR) is a state-of-the-art method for obtaining CT images. This study aimed to evaluate the usefulness of DLR in radiotherapy. Data were acquired using a large-bore CT system and an electron density phantom for radiotherapy. We compared the CT values, image noise, and CT value-to-electron density conversion table of DLR and hybrid iterative reconstruction (H-IR) for various doses. Further, we evaluated three DLR reconstruction strength patterns (Mild, Standard, and Strong). The variations of CT values of DLR and H-IR were large at low doses, and the difference in average CT values was insignificant with less than 10 HU at doses of 100 mAs and above. DLR showed less change in CT values and smaller image noise relative to H-IR. The noise-reduction effect was particularly large in the low-dose region. The difference in image noise between DLR Mild and Standard/Strong was large, suggesting the usefulness of reconstruction intensities higher than Mild. DLR showed stable CT values and low image noise for various materials, even at low doses; particularly for Standard or Strong, the reduction in image noise was significant. These findings indicate the usefulness of DLR in treatment planning using large-bore CT systems.
  • 安井啓祐
    日本診療放射線技師会誌, 70(846) 85-90, Apr, 2023  Lead author

Misc.

 43

Books and Other Publications

 2

Presentations

 38

Teaching Experience

 17

Research Projects

 9

Other

 2
  • 放射線線量率に対する細胞生存率計測のための多様な種類の細胞 *本研究ニーズに関する産学共同研究の問い合わせは藤田医科大学産学連携推進セン ター(fuji-san@fujita-hu.ac.jp)まで
  • 放射線線量計測における検出器の応答特性検証技術 ガラス線量計、半導体検出器等で検証を実施 (Yasui et al; Physica Medica 81 147-154 2021年1月, IJRR 19((2)) 281-289 2021年4月, Nagata et al; JACMP 22(8) 265-272 2021年8月) *本研究ニーズに関する産学共同研究の問い合わせは藤田医科大学産学連携推進セン ター(fuji-san@fujita-hu.ac.jp)まで