研究者業績
基本情報
- 所属
- 藤田医科大学 医療科学部 講師
- 学位
- 博士(医療技術学)(名古屋大学)
- 研究者番号
- 00810748
- J-GLOBAL ID
- 201801015381626216
- researchmap会員ID
- B000307483
研究キーワード
4経歴
4-
2023年4月 - 現在
-
2019年4月 - 2023年3月
-
2018年4月 - 2019年3月
-
2013年4月 - 2019年3月
学歴
4-
2015年4月 - 2018年3月
-
2011年4月 - 2013年3月
-
2007年4月 - 2011年3月
-
2004年4月 - 2007年3月
委員歴
1-
2021年4月 - 現在
受賞
9-
2025年9月
-
2025年9月
-
2024年9月
-
2024年4月
-
2022年11月
主要な論文
32-
Journal of Applied Clinical Medical Physics 26(4) 2025年2月20日 査読有り筆頭著者責任著者Abstract Purpose The energy threshold is an important parameter for precise material identification employing photon‐counting techniques. However, in such applications, the appropriate energy threshold has not been clarified. Therefore, we aimed to determine the appropriate energy threshold range for precise material identification, focusing on effective atomic number (Z) values as an index. Methods The atomic number was estimated using a previously proposed algorithm and Monte Carlo simulations. This algorithm included three steps: calculating the attenuation factor from the incident photon counts on a photon‐counting detector, correcting the beam‐hardening effects, and estimating the atomic number from the attenuation factor index using the calibration curve. Monte Carlo simulations were performed to add Poisson noise to an ideal x‐ray spectrum. The total number of incident x‐rays was set in the range of 103–106. The x‐ray spectra were generated at tube voltages of 50–120 kV. Polymethyl methacrylate (Z = 6.5) and aluminum (Z = 13) were used for the analysis. The energy threshold was varied at intervals of 1 keV to estimate the atomic number. We evaluated the appropriate energy threshold range for accurately estimating the atomic number using the obtained atomic number data and statistical uncertainty under various conditions. Results The appropriate energy threshold range was found to be 31–38 keV for a tube voltage range of 50–120 kV. At this energy threshold, the atomic number can be estimated within an accuracy of ± 0.7 at 105 counts for the atomic number range of 6.5 (PMMA) to 13 (Al). Conclusions We found the appropriate energy threshold range. The findings of this study are expected to be useful for appropriately setting the energy threshold during precise material identification using photon‐counting detectors for clinical applications.
-
Physica Medica 118 2024年2月 査読有り筆頭著者責任著者
-
Physica Medica 81 130-140 2021年1月 査読有り筆頭著者責任著者
-
Physical and Engineering Sciences in Medicine 43 155-162 2019年12月 査読有り筆頭著者Size-specific dose estimate (SSDE) was proposed by the American Association of Physicists in Medicine (AAPM) Task Group 204 to consider the effect of patient size in the x-ray CT dose estimation. Size correction factors to calculate SSDE were derived based on the conventional weighted CT dose index (CTDIw) equation. This study aims to investigate the influence of Bakalyar's and the authors' own CTDIw equations on the size correction factors described by the AAPM Task Group 204, using Monte Carlo simulations. The simulations were performed by modeling four types of x-ray CT scanner designs, to compute the dose values in water for cylindrical phantoms with 8-40 cm diameters. CTDI100 method and the AAPM Task Group 111's proposed method were employed as the CT dosimetry models. Size correction factors were obtained for the computed dose values of various phantom diameters for the conventional, Bakalyar's, and the authors' weighting factors. Maximum difference between the size correction factors for the Bakalyar's weighting factor and those of the AAPM Task Group 204 was 27% for a phantom diameter of 11.2 cm. On the other hand, the size correction factors calculated for the authors' weighting factor were in good agreement with those from the AAPM Task Group 204 report with a maximum difference of 17%. The results indicate that the SSDE values obtained with the authors' weighting factor can be evaluated by using the size correction factors reported by the AAPM Task Group 204, which is currently accepted as a standard.
-
Australasian physical & engineering sciences in medicine 41(4) 847-852 2018年12月 査読有りX-ray image evaluation is commonly performed by determining the detective quantum efficiency (DQE). DQE is calculated with a presampled modulation transfer function (MTF), incident photon fluence, and digital noise power spectrum (NPS). Accurate evaluation of MTF, incident photon fluence, and NPS is important for precise DQE determination. In this study, we focused on the accuracy of the incident photon fluence in mammography. The incident photon fluence is calculated using the squared signal-to-noise ratio (SNRin2) value as specified in the International Electrotechnical Commission (IEC) 62220-1-2 report. However, the reported SNRin2 values were determined using a computer program, and the reported values may differ from those calculated from an X-ray spectrum that is measured with actual mammography equipment. Therefore, we evaluated the error range of reported SNRin2 values in mammography to assess the accuracy of the incident photon fluence. First, X-ray spectra from various mammography systems were measured with a CdTe spectrometer. Six mammographic X-ray units were used in this study. Second, the SNRin2 values were calculated from the measured X-ray spectra. The calculated values were compared to the reported values. The results show that the percentage differences between the calculated and reported SNRin2 values were within - 4.1% of each other. The results obtained in this study indicate that the SNRin2 values provided in the IEC report are a robust and convenient tool for calculating the incident photon fluence for DQE evaluation in mammography.
-
MEDICAL PHYSICS 44(12) 6603-6609 2017年12月 査読有り
-
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 39(3) 697-703 2016年9月 査読有り
-
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS 32(7) 905-913 2016年7月 査読有り
-
Radiological Physics and Technology 7(1) 133-140 2014年 査読有り
-
Radiological Physics and Technology 6(2) 423-430 2013年7月 査読有り
-
Progress in Nuclear Science and Technology 3 72-75 2012年 査読有り
MISC
11-
Proceedings of the Twenty-Second EGS User's Meeting in Japan 19-24 2015年There has been a growing concern regarding exposure to superficial radiosensitive organs with the rapid increase of computed tomography examinations. Manufacturers have been developing various dose reduction methods in order to prevent harm to these organs. Our previous study revealed a unique phenomenon in X-ray computed tomography scanning, in which the maximum absorbed dose position shifts to a deeper region from the surface in a water cylindrical phantom. We considered that this result could be applied as a dose reduction method. Therefore, in this study, we investigate the tube voltage dependence of this unique phenomenon. The results show that the peak dose position shifts to a deeper region with increasing tube voltage. The superficial radiosensitive organs can thus be protected from peak dose exposure by adjusting the tube voltage.
書籍等出版物
1講演・口頭発表等
56-
The 2025 IEEE Nuclear Science Symposium and Medical Imaging Conference 2025年11月
-
第76回日本放射線技術学会総会学術大会 2020年4月
-
European Congress of Radiology 2013年3月
-
European Congress of Radiology 2013年3月
-
Basic examination on estimation accuracy of intravascular hemodynamics using the quasi-Newton methodInternational Forum on Medical Imaging in Asia 2012年11月
-
Nagoya-Yonsei University Research Exchange Meeting on Health Sciences 2011年11月
担当経験のある科目(授業)
11-
2023年4月 - 現在医療安全管理学 (藤田医科大学)
-
2023年4月 - 現在放射線計測学Ⅱ (藤田医科大学)
-
2023年4月 - 現在モンテカルロシミュレーション (藤田医科大学)
-
2022年4月 - 現在放射線医学概論(一般撮影、血管造影検査) (藤田医科大学)
-
2020年4月 - 現在診療画像技術学Ⅱ(血管造影検査) (藤田医科大学)
所属学協会
2共同研究・競争的資金等の研究課題
7-
日本学術振興会 科学研究費助成事業 2024年4月 - 2027年3月
-
公益財団法人 愛知県がん研究振興会 第50回(2025年度)がんその他の悪性新生物研究助成金 2025年4月 - 2026年3月
-
日本学術振興会 科学研究費助成事業 2023年4月 - 2026年3月
-
日本学術振興会 科学研究費助成事業 2022年4月 - 2025年3月
-
日本学術振興会 科学研究費助成事業 2019年4月 - 2022年3月