医学部

Hiroko Watase

  (渡瀬 博子)

Profile Information

Affiliation
Fujita Health University

ORCID ID
 https://orcid.org/0000-0002-8951-7692
J-GLOBAL ID
202101009280963608
researchmap Member ID
R000023643

Papers

 54
  • Akihiko Sugaya, Keiko Naito, Tadahiro Goto, Yusuke Hagiwara, Hiroshi Okamoto, Hiroko Watase, Kohei Hasegawa
    Cureus, 15(10) e47563, Oct, 2023  
    BACKGROUND: The video laryngoscope (VL) has been widely used for intubation in the emergency department (ED). However, their effectiveness remains controversial, particularly among airway management performed by residents in the ED. METHODS: We aimed to examine whether the use of VL, compared to a direct laryngoscope (DL), was associated with higher first-attempt intubation success among intubations performed by residents in the ED. This is a secondary analysis of the data from a prospective, observational, multicentre study of 15 Japanese EDs from April 2012 through March 2020. We included all adult patients who underwent intubation with VL or DL by residents (postgraduate years ≤5) in the ED. The outcome measures were first-pass success and intubation-related adverse events (overall, major, and minor adverse events). To determine the association of VL use with each of the outcomes, we constructed logistic regression models with generalized estimating equations to account for patients clustering within the ED, adjusting for patient demographics, primary indications, intubation difficulty, and intubation methods. RESULTS: Of 5,261 eligible patients who underwent an initial intubation attempt by residents, 1,858 (35%) patients were attempted with VL. Intubations performed with VL had a non-significantly higher first-pass success rate than those with DL (77% vs. 64%; unadjusted odds ratio (OR)=1.20; 95% CI=0.87-1.65; P=0.27). This association was significant after adjustment for potential confounders (adjusted OR, 1.33; 95% CI, 1.06-1.67; P=0.01). As for adverse events, the use of VL was associated with a lower rate of any (adjusted OR=0.67; 95% CI=0.51-0.86; P=0.002) and minor (adjusted OR=0.69; 95% CI=0.55-0.87; P=0.002) adverse events. CONCLUSION: The use of VL was associated with a higher first-attempt success rate and a lower rate of any adverse events compared to that with DL among intubations performed by residents in the EDs.
  • Sai Shao, Honglu Shi, Guangbin Wang, Rui Li, Qinjian Sun, Bin Yao, Hiroko Watase, Daniel S Hippe, Chun Yuan, Xihai Zhao
    Stroke and Vascular Neurology, 8(4) 284-291, Aug, 2023  
    BACKGROUND AND PURPOSE: Atherosclerosis is a very complex process influenced by various systemic and local factors. Therefore, in patients with bilateral carotid plaques (BCPs), there may be differences in carotid plaque vulnerability between the sides. We aimed to investigate the differences in BCP characteristics in patients with BCPs using magnetic resonance vessel wall imaging (MR-VWI). METHODS: Participants with BCPs were selected for subanalysis from a multicentre study of Chinese Atherosclerosis Risk Evaluation II. We measured carotid plaque burden, identified each plaque component and measured their volume or area bilaterally on MR-VWI. Paired comparisons of the burden and components of BCPs were performed. RESULTS: In all, 540 patients with BCPs were eligible for analysis. Compared with the right carotid artery (CA), larger mean lumen area (p<0.001), larger mean wall area (p=0.025), larger mean total vessel area (p<0.001) and smaller normalised wall index (p=0.006) were found in the left CA. Regarding plaque components, only the prevalence of lipid-rich necrotic core (LRNC) in the left CA was higher (p=0.026). For patients with a vulnerable plaque component coexisting on both sides, only the intraplaque haemorrhage (IPH) volume (p=0.011) was significantly greater in the left CA than in the right CA. CONCLUSIONS: There were asymmetries in plaque growth and evolution between BCPs. The left carotid plaques were more likely to have larger plaque burden, higher prevalence of LRNC and greater IPH volume, which may contribute to the lateralisation of ischaemic stroke in the cerebral hemispheres.
  • Manabu Shirakawa, Kiyofumi Yamada, Hiroko Watase, Baocheng Chu, Yukiko Enomoto, Takao Kojima, Kazuki Wakabayashi, Jie Sun, Daniel S Hippe, Marina S Ferguson, Niranjan Balu, Shinichi Yoshimura, Thomas S Hatsukami, Chun Yuan
    Journal of the neurological sciences, 446 120582-120582, Mar 15, 2023  
    Recent studies report that the rate of recurrent stroke is highest in the stages immediately following cerebral infarction and decreases over time in patients with atherosclerotic carotid stenosis. The purpose of this study was to identify temporal differences in early stage carotid plaque components from acute cerebrovascular ischemic events using carotid MRI. Carotid plaque images were obtained on 3 T MRI from 128 patients enrolled in MR-CAS. Among the 128 subjects, 53 were symptomatic and 75 asymptomatic. The symptomatic patients were classified into three groups based on interval from onset of symptoms to the date of the carotid MRI (Group <14 days; 15-30 days; and > 30 days). The volume of each plaque component was identified and quantified from MR images. The presence of juxtaluminal loose matrix/inflammation (LM/I) was identified as a possible indicator of inflammation on the luminal side. Plaque components were compared between groups using the Wilcoxon rank-sum or the Chi-square test. Patient characteristics and carotid plaque morphology were similar among all four groups. The median volume of LM/I in Group >30 days was significantly lower than in other groups (0 mm3 vs 12.3 mm3 and 18.1 mm3; p = 0.003). In addition, the prevalence of juxtaluminal LM/I decreased over time (ptrend = 0.002). There were no statistically significant differences in other plaque components between the symptomatic groups. The volume of LM/I was significantly smaller in Group >30 days and prevalence of juxtaluminal LM/I in the atherosclerotic carotid plaque was high in the early stages after events. This suggests that carotid plaques undergo rapid evolution after an acute cerebrovascular ischemic event.
  • Jin Takahashi, Tadahiro Goto, Shigeki Fujitani, Hiroshi Okamoto, Yusuke Hagiwara, Hiroko Watase, Kohei Hasegawa
    Frontiers in medicine, 10 1199750-1199750, 2023  
    BACKGROUND: Airway obstruction is a relatively rare but critical condition that requires urgent intervention in the emergency department (ED). The present study aimed to investigate the association of airway obstruction with first-pass success and intubation-related adverse events in the ED. METHODS: We analyzed data from two prospective multicenter observational studies of ED airway management. We included adults (aged ≥18 years) who underwent tracheal intubation for non-trauma indications from 2012 through 2021 (113-month period). Outcome measures were first-pass success and intubation-related adverse events. We constructed a multivariable logistic regression model adjusting for age, sex, modified LEMON score (without airway obstruction), intubation methods, intubation devices, bougie use, intubator's specialty, and ED visit year with accounting for patients clustering within the ED. RESULTS: Of 7,349 eligible patients, 272 (4%) underwent tracheal intubation for airway obstruction. Overall, 74% of patients had first-pass success and 16% had intubation-related adverse events. The airway obstruction group had a lower first-pass success rate (63% vs. 74%; unadjusted odds ratio [OR], 0.63; 95% CI, 0.49-0.80), compared to the non-airway obstruction group. This association remained significant in the multivariable analysis (adjusted OR 0.60, 95%CI 0.46-0.80). The airway obstruction group also had a significantly higher risk of adverse events (28% vs. 16%; unadjusted OR, 1.93; 95% CI, 1.48-2.56, adjusted OR, 1.70; 95% CI, 1.27-2.29). In the sensitivity analysis using multiple imputation, the results remained consistent with the main results: the airway obstruction group had a significantly lower first-pass success rate (adjusted OR, 0.60; 95% CI, 0.48-0.76). CONCLUSION: Based on these multicenter prospective data, airway obstruction was associated with a significantly lower first-pass success rate and a higher intubation-related adverse event rate in the ED.
  • Jin Takahashi, Tadahiro Goto, Shigeki Fujitani, Hiroshi Okamoto, Yusuke Hagiwara, Hiroko Watase, Kohei Hasegawa
    Frontiers in medicine, 10 1307868-1307868, 2023  
    [This corrects the article DOI: 10.3389/fmed.2023.1199750.].

Misc.

 46