研究者業績

陶山 謙一郎

スヤマ ケンイチロウ  (Kenichiro Suyama)

基本情報

所属
藤田医科大学 医学部脳神経外科学 講師

研究者番号
00833948
ORCID ID
 https://orcid.org/0000-0002-0147-5564
J-GLOBAL ID
202401009909997308
researchmap会員ID
R000075415

論文

 31
  • Jun Tanabe, Ichiro Nakahara, Kenichi Haraguchi, Akiko Hasebe, Kenichiro Suyama, Fuminari Komatsu, Yasuhiro Yamada, Riki Tanaka, Kento Sasaki, Kotaro Kihara, Yoko Kato
    Neuroradiology 2025年11月7日  
    BACKGROUND: This study evaluated the safety and efficacy of a treatment strategy for Posterior communicating artery (PCOM) aneurysms using first-line Woven EndoBridge (WEB), supplemented by Flow diverter (FD) in selected cases. METHODS: This retrospective study included patients who underwent endovascular treatment for PCOM aneurysms between January 2021 and March 2025. Aneurysms were categorized as fetal or non-fetal. A first-line WEB strategy was adopted when morphology was suitable. Radiological and clinical outcomes were assessed. RESULTS: Forty-six PCOM aneurysms met the criteria: 14 fetal-type and 32 non-fetal-type. All previously untreated fetal-type aneurysms were treated with WEB (n = 9). In the non-fetal group, the initial treatments included WEB (n = 14), FD (n = 10), and coiling (n = 4). All recurrent fetal-type aneurysms were retreated with FD (n = 5), whereas non-fetal recurrences were managed with FD (n = 3) or coiling (n = 1), depending on prior treatment. At a median follow-up of 21 months, complete occlusion was achieved in 66.7% of fetal-type and 59.4% of non-fetal-type aneurysms (P = 0.739), and adequate occlusion was achieved in 75.0% and 90.6%, respectively (P = 0.321). Retreatment was required in two cases (4.3%): one in the fetal group (7.1%) and one in the non-fetal group (3.1%) (p = 0.512). No modified Rankin Scale worsening or major complications occurred. No significant differences in treatment efficacy were observed among modalities selected under the WEB first-line strategy. CONCLUSION: A first-line WEB strategy is safe and effective for PCOM aneurysms, including fetal-type variants, with outcomes for fetal-type aneurysms comparable to non-fetal-type aneurysms.
  • Jun Tanabe, Ichiro Nakahara, Shoji Matsumoto, Jun Morioka, Tetsuya Hashimoto, Akiko Hasebe, Sadayoshi Watanabe, Kenichiro Suyama, Takeya Suzuki, Junpei Koge
    Neurointervention 2025年11月1日  
  • Kenichiro Suyama, Ichiro Nakahara, Shoji Matsumoto, Junpei Koge, Jun Tanabe, Akiko Hasebe, Eiji Fujiwara, Shiho Tanaka, Tatsunori Mase, Yuichi Hirose
    Journal of NeuroInterventional Surgery jnis-2025 2025年6月20日  査読有り筆頭著者
    Purpose Digital subtraction angiography (DSA) is the gold standard for follow-up evaluation of intracranial aneurysms treated with the Woven EndoBridge (WEB) device. This study aimed to assess the efficacy of high-resolution CT angiography (HR-CTA) as a less invasive alternative by comparing its diagnostic performance with that of DSA. Methods This single-center retrospective study analyzed the angiographic and clinical data of patients treated with the WEB device for cerebral aneurysms between January 2021 and December 2024. Patients who underwent HR-CTA within 2 weeks before or after follow-up DSA were included. Occlusion status was assessed using the Bicêtre Occlusion Scale Score (BOSS) and binary classification. The concordance rate between HR-CTA and DSA was evaluated. Results A total of 54 eligible examinations were identified. Using the BOSS, 46 examinations were concordant, resulting in an agreement rate of 85.2%. The Cohen’s κ coefficient was 0.81 (95% CI 0.69 to 0.93), indicating a very high level of agreement. All discordant cases resulted from HR-CTA overestimating occlusion status; however, HR-CTA accurately identified aneurysm remnants. Univariate analyses identified BOSS 0’ as the only significant factor contributing to discrepancies. In the binary evaluation, all 54 examinations were fully concordant (κ=1.00, 95% CI 1.00 to 1.00). Conclusions HR-CTA demonstrated a high concordance rate with DSA for evaluating occlusion status after WEB placement. Its reliable assessment of aneurysm remnants suggests HR-CTA could serve as a practical and less invasive alternative to DSA in follow-up evaluations.
  • Kenichiro Suyama, Ichiro Nakahara, Shoji Matsumoto, Jun Morioka, Tetsuya Hashimoto, Junpei Koge, Jun Tanabe, Akiko Hasebe, Sadayoshi Watanabe, Takeya Suzuki, Yuichi Hirose
    Journal of Clinical Neuroscience 135 111192-111192 2025年5月  査読有り筆頭著者
  • Akiko Hasebe, Ichiro Nakahara, Kenichiro Suyama, Shoji Matsumoto, Jun Morioka, Tetsuya Hashimoto, Jun Tanabe, Sadayoshi Watanabe, Takeya Suzuki, Junpei Koge
    Asian journal of neurosurgery 20(1) 143-148 2025年3月  
    We report a case in which a novel distal access catheter proved successful in the placement of a flow diverter for a challenging distal cerebral artery lesion. We discuss the advantages and pitfalls of this technique and considerations for its use. A 74-year-old female presented with intermittent headaches, and was diagnosed with a dissecting aneurysm at the proximal right posterior cerebral artery with a sharp bleb, measuring 9.8 mm in diameter. Given the complex vascular anatomy, stent-assisted coil embolization was initially considered but deemed high risk for dual catheter for jailing technique with 6-Fr size guiding catheter due to the tortuosity and stenosis of the parent vessel. Therefore, we opted for flow diverter treatment, which presented its challenges during delivery. By employing a low-profile distal access catheter, Phenom Plus (outer diameter: 4.2-Fr. inner diameter: 1.13 mm; Medtronic, Minneapolis, Minnesota, United States), with a minimal ledge between it and the delivery catheter, Phenom 27 (outer diameter: 2.8-Fr, 0.91 mm; Medtronic), we successfully crossed the neck of the aneurysm with Phenom Plus and placed the flow diverter. While acknowledging potential risks, this case demonstrates the value of the neck-crossing technique using a low-profile distal access catheter as an alternative option for treating challenging peripheral artery aneurysms with flow diverters. This technique offers promise in specific situations where conventional methods pose challenges.

MISC

 7

講演・口頭発表等

 10