研究者業績
基本情報
- 所属
- 藤田医科大学 医療科学部臨床教育連携ユニット医学物理学分野 教授
- 学位
- 博士(医療技術学)(名古屋大学)修士(保健学)(金沢大学)
- 研究者番号
- 00549884
- J-GLOBAL ID
- 201201043293710753
- researchmap会員ID
- B000219735
経歴
7-
2024年4月 - 現在
-
2018年10月 - 2024年3月
-
2016年4月 - 2018年10月
-
2014年4月 - 2018年3月
-
2012年4月 - 2016年3月
委員歴
38-
2023年2月 - 現在
-
2022年7月 - 現在
-
2021年4月 - 現在
-
2021年4月 - 現在
受賞
2-
2024年4月
-
2010年4月
論文
96-
Medical Physics 2025年3月29日Abstract Background Accurate dosimetry is important in radiotherapy, and all equipment used for radiotherapy shoud be audited by an independent external dose audit. Radiophotoluminescence glass dosimeter (RPLD) has excellent characteristics and is widely used for postal dose audit; however, postal dose audit for proton therapy using RPLD has not been established. Purpose This study aims to develop a postal dose audit procedure for scanning proton beams using RPLD, estimate uncertainties, and conduct a multicenter pilot study to validate the methodology. Methods A postal toolkit was developed and a postal dose audit procedure for RPLD measurements of scanning proton beams was established in cooperation with several facilities that employ various accelerators, irradiation equipment, and treatment planning systems (TPS) for clinical use. Based on basic and previous studies, an uncertainty budget was developed for estimating relative uncertainty and pilot studies were conducted at each site. A method for postal dose audits was developed in a multicenter collaboration to develop an approach suitable for implementation across multiple facilities. Results The relative response of 60 RPLDs for scanning proton beam examined in this study was 1.00 ± 1.28% mean ± standard deviation. The combined relative standard uncertainty of postal dosimetry for scanning proton beams using the RPLD was 2.97% (k = 1). Under the reference condition, the maximum differences between the ionization chamber measurement (IC) and TPS, RPLD and TPS, and RPLD and IC were 0.97, 1.88, and 2.12%, respectively. The maximum differences between the RPLD and ionization chamber for plateau measurements at 3 cm depth using single‐energy and non‐reference conditions were 11.31 and 4.02%, respectively. Conclusion We established a procedure for the postal dose audits of proton beams using RPLD and presented the results of a multicenter pilot study. By standardizing the reference conditions, the dosimetry uncertainty was estimated at 2.92%. The results demonstrated the feasibility of performing an independent third‐party dose audit of scanning proton beams using RPLD, and for such postal dose audits for proton beams, the irradiation conditions should be standardized to reduce uncertainties. These results are expected to contribute to the development of proton beams.
-
Journal of Applied Clinical Medical Physics 2025年1月 査読有り筆頭著者責任著者
-
Radiological physics and technology 2024年9月10日 査読有りThis study aimed to evaluate the performance for answering the Japanese medical physicist examination and providing the benchmark of knowledge about medical physics in language-generative AI with large language model. We used questions from Japan's 2018, 2019, 2020, 2021 and 2022 medical physicist board examinations, which covered various question types, including multiple-choice questions, and mainly focused on general medicine and medical physics. ChatGPT-3.5 and ChatGPT-4.0 (OpenAI) were used. We compared the AI-based answers with the correct ones. The average accuracy rates were 42.2 ± 2.5% (ChatGPT-3.5) and 72.7 ± 2.6% (ChatGPT-4), showing that ChatGPT-4 was more accurate than ChatGPT-3.5 [all categories (except for radiation-related laws and recommendations/medical ethics): p value < 0.05]. Even with the ChatGPT model with higher accuracy, the accuracy rates were less than 60% in two categories; radiation metrology (55.6%), and radiation-related laws and recommendations/medical ethics (40.0%). These data provide the benchmark for knowledge about medical physics in ChatGPT and can be utilized as basic data for the development of various medical physics tools using ChatGPT (e.g., radiation therapy support tools with Japanese input).
-
Radiological Physics and Technology 17(1) 280-287 2024年1月23日 査読有りThe reference dose for clinical proton beam therapy is based on ionization chamber dosimetry. However, data on uncertainties in proton dosimetry are lacking, and multifaceted studies are required. Monte Carlo simulations are useful tools for calculating ionization chamber dosimetry in radiation fields and are sensitive to the transport algorithm parameters when particles are transported in a heterogeneous region. We aimed to evaluate the proton transport algorithm of the Particle and Heavy Ion Transport Code System (PHITS) using the Fano test. The response of the ionization chamber f Q and beam quality correction factors k Q were calculated using the same parameters as those in the Fano test and compared with those of other Monte Carlo codes for verification. The geometry of the Fano test consisted of a cylindrical gas-filled cavity sandwiched between two cylindrical walls. f Q was calculated as the ratio of the absorbed dose in water to the dose in the cavity in the chamber. We compared the f Q calculated using PHITS with that of a previous study, which was calculated using other Monte Carlo codes (Geant4, FULKA, and PENH) under similar conditions. The flight mesh, a parameter for charged particle transport, passed the Fano test within 0.15%. This was shown to be sufficiently accurate compared with that observed in previous studies. The f Q calculated using PHITS were 1.116 ± 0.002 and 1.124 ± 0.003 for NACP-02 and PTW-30013, respectively, and the k Q were 0.981 ± 0.008 and 1.027 ± 0.008, respectively, at 150 MeV. Our results indicate that PHITS can calculate the f Q and k Q with high precision.
-
Nihon Hoshasen Gijutsu Gakkai zasshi 80(1) 79-86 2024年
MISC
32-
日本放射線技術学会雑誌 = Japanese journal of radiological technology 67(1) 103-106 2011年1月
-
日本放射線技術學會雜誌 66(10) 1354-1354 2010年10月20日
-
日本放射線技術學會雜誌 66(2) 160-161 2010年2月20日
-
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS 78(3) S824-S824 2010年
-
日本放射線技術學會雜誌 64(9) 1133-1133 2008年9月20日
-
日本放射線技術學會雜誌 63(9) 1025-1025 2007年9月20日
-
日本放射線技術學會雜誌 62(9) 1261-1261 2006年9月20日
-
日本放射線技術學會雜誌 62(9) 1262-1262 2006年9月20日
-
放射線防護分科会会誌 (19) 26-26 2004年10月21日
-
放射線防護分科会会誌 (19) 56-56 2004年10月21日
-
放射線防護分科会会誌 (19) 25-25 2004年10月21日
書籍等出版物
14講演・口頭発表等
62-
Asia Oceania Congress of Medical Physics 2024 2024年10月12日
-
Asia Oceania Congress of Medical Physics 2024 2024年10月12日
-
AAPM2024 66th Annual Meeting 2024年7月21日
-
第127回日本医学物理学会学術集会 2024年4月13日
担当経験のある科目(授業)
14-
2018年4月 - 現在国際医学概論 (藤田医科大学)
-
放射線技術学特論 (藤田医科大学)
-
放射線医学概論 (藤田医科大学)
-
放射線機器管理工学特論 (藤田医科大学)
-
放射線診断機器工学実験 (藤田医科大学)
共同研究・競争的資金等の研究課題
9-
日本学術振興会 科学研究費助成事業 基盤研究(C) 2022年4月 - 2025年3月
-
日本学術振興会 科学研究費助成事業 基盤研究(C) 2022年4月 - 2025年3月
-
日本学術振興会 科学研究費助成事業 基盤研究(C) 2019年4月 - 2022年3月
-
日本学術振興会 科学研究費助成事業 基盤研究(C) 2019年4月 - 2022年3月
-
日本学術振興会 科学研究費助成事業 2016年4月 - 2019年3月
作成した教科書、教材、参考書
3-
件名診療放射線技術ガイド(第3版)終了年月日2014/04概要共著にて作成。現場で活躍する診療放射線技師にとって必要な実践的な知識を網羅する教科書である。私は放射線治療技術に関する項を担当しました。
-
件名外部放射線治療における水吸収線量の標準計測法開始年月日2012/09/10概要本邦の外部放射線治療における吸収線量の標準的計測法を記述する本を医学物理学会の編集メンバーとともに分担執筆した.私はラジオクロミックフィルムの章と光子線計測に関する部分を担当した.
-
件名新・医用放射線技術実験:基礎編開始年月日2016/04/01概要診療放射線技師を養成する大学において学生実験を行うための教科書を分担執筆した.私はラジオクロミックフィルムを用いた線量計測を担当した.