Curriculum Vitaes
Profile Information
- Affiliation
- Professor, Division of Medical Physics, School of Medical Sciences, Fujita Health University
- Degree
- Ph.D(Nagoya University)M.Sc.(Kanazawa University)
- Researcher number
- 00549884
- J-GLOBAL ID
- 201201043293710753
- researchmap Member ID
- B000219735
Research Areas
3Research History
7-
Oct, 2018 - Mar, 2024
-
Apr, 2016 - Oct, 2018
-
Apr, 2014 - Mar, 2018
-
Apr, 2012 - Mar, 2016
Committee Memberships
38-
Feb, 2023 - Present
-
Apr, 2021 - Present
-
Apr, 2021 - Present
-
Apr, 2021 - Present
Awards
2Papers
96-
Medical Physics, Mar 29, 2025Abstract Background Accurate dosimetry is important in radiotherapy, and all equipment used for radiotherapy shoud be audited by an independent external dose audit. Radiophotoluminescence glass dosimeter (RPLD) has excellent characteristics and is widely used for postal dose audit; however, postal dose audit for proton therapy using RPLD has not been established. Purpose This study aims to develop a postal dose audit procedure for scanning proton beams using RPLD, estimate uncertainties, and conduct a multicenter pilot study to validate the methodology. Methods A postal toolkit was developed and a postal dose audit procedure for RPLD measurements of scanning proton beams was established in cooperation with several facilities that employ various accelerators, irradiation equipment, and treatment planning systems (TPS) for clinical use. Based on basic and previous studies, an uncertainty budget was developed for estimating relative uncertainty and pilot studies were conducted at each site. A method for postal dose audits was developed in a multicenter collaboration to develop an approach suitable for implementation across multiple facilities. Results The relative response of 60 RPLDs for scanning proton beam examined in this study was 1.00 ± 1.28% mean ± standard deviation. The combined relative standard uncertainty of postal dosimetry for scanning proton beams using the RPLD was 2.97% (k = 1). Under the reference condition, the maximum differences between the ionization chamber measurement (IC) and TPS, RPLD and TPS, and RPLD and IC were 0.97, 1.88, and 2.12%, respectively. The maximum differences between the RPLD and ionization chamber for plateau measurements at 3 cm depth using single‐energy and non‐reference conditions were 11.31 and 4.02%, respectively. Conclusion We established a procedure for the postal dose audits of proton beams using RPLD and presented the results of a multicenter pilot study. By standardizing the reference conditions, the dosimetry uncertainty was estimated at 2.92%. The results demonstrated the feasibility of performing an independent third‐party dose audit of scanning proton beams using RPLD, and for such postal dose audits for proton beams, the irradiation conditions should be standardized to reduce uncertainties. These results are expected to contribute to the development of proton beams.
-
Journal of Applied Clinical Medical Physics, Jan, 2025 Peer-reviewedLead authorCorresponding author
-
Radiological physics and technology, Sep 10, 2024 Peer-reviewedThis study aimed to evaluate the performance for answering the Japanese medical physicist examination and providing the benchmark of knowledge about medical physics in language-generative AI with large language model. We used questions from Japan's 2018, 2019, 2020, 2021 and 2022 medical physicist board examinations, which covered various question types, including multiple-choice questions, and mainly focused on general medicine and medical physics. ChatGPT-3.5 and ChatGPT-4.0 (OpenAI) were used. We compared the AI-based answers with the correct ones. The average accuracy rates were 42.2 ± 2.5% (ChatGPT-3.5) and 72.7 ± 2.6% (ChatGPT-4), showing that ChatGPT-4 was more accurate than ChatGPT-3.5 [all categories (except for radiation-related laws and recommendations/medical ethics): p value < 0.05]. Even with the ChatGPT model with higher accuracy, the accuracy rates were less than 60% in two categories; radiation metrology (55.6%), and radiation-related laws and recommendations/medical ethics (40.0%). These data provide the benchmark for knowledge about medical physics in ChatGPT and can be utilized as basic data for the development of various medical physics tools using ChatGPT (e.g., radiation therapy support tools with Japanese input).
-
Radiological Physics and Technology, 17(1) 280-287, Jan 23, 2024 Peer-reviewedThe reference dose for clinical proton beam therapy is based on ionization chamber dosimetry. However, data on uncertainties in proton dosimetry are lacking, and multifaceted studies are required. Monte Carlo simulations are useful tools for calculating ionization chamber dosimetry in radiation fields and are sensitive to the transport algorithm parameters when particles are transported in a heterogeneous region. We aimed to evaluate the proton transport algorithm of the Particle and Heavy Ion Transport Code System (PHITS) using the Fano test. The response of the ionization chamber f Q and beam quality correction factors k Q were calculated using the same parameters as those in the Fano test and compared with those of other Monte Carlo codes for verification. The geometry of the Fano test consisted of a cylindrical gas-filled cavity sandwiched between two cylindrical walls. f Q was calculated as the ratio of the absorbed dose in water to the dose in the cavity in the chamber. We compared the f Q calculated using PHITS with that of a previous study, which was calculated using other Monte Carlo codes (Geant4, FULKA, and PENH) under similar conditions. The flight mesh, a parameter for charged particle transport, passed the Fano test within 0.15%. This was shown to be sufficiently accurate compared with that observed in previous studies. The f Q calculated using PHITS were 1.116 ± 0.002 and 1.124 ± 0.003 for NACP-02 and PTW-30013, respectively, and the k Q were 0.981 ± 0.008 and 1.027 ± 0.008, respectively, at 150 MeV. Our results indicate that PHITS can calculate the f Q and k Q with high precision.
-
Nihon Hoshasen Gijutsu Gakkai zasshi, 80(1) 79-86, 2024
Misc.
32Books and Other Publications
14Presentations
62-
Asia Oceania Congress of Medical Physics 2024, Oct 12, 2024
-
Asia Oceania Congress of Medical Physics 2024, Oct 12, 2024
-
AAPM2024 66th Annual Meeting, Jul 21, 2024
-
JSMP127, Apr 13, 2024
-
International Conference on Medical Physics 2023 in Mumbai, Dec 9, 2023 Invited
-
International Conference on Medical Physics 2023 in Mumbai, Dec 7, 2023
-
The 65th annual meeting of American Association of Physicists in Medicine, Jul 22, 2023
-
The 79th scientific meeting of Japanese society of radiological technology, Apr 15, 2023 Invited
-
The 124th scientific meeting of Japan society of medical physics, Sep 16, 2022 Invited
-
The 64th annual meeting of American Association of Physicist in Medicine, Jul 9, 2022 Invited
-
The 78th meeting of Japanese society of radiological technology, Apr 17, 2022
-
The 61st Annual meeting of American Association of Physicists in Medicine, Jul 17, 2019
-
The 60th annual meeting of American Association of Physicists in Medicine, Jul 29, 2018
-
The 59th annual meeting of American Association of Physicists in Medicine, Jul 30, 2017
-
International Congress of Medical Physics in 2016, Dec 11, 2016
-
The 58th annual meeting of American Association of Physicists in Medicine, Jul 31, 2016
-
The 43rd Autumn annual meeting of Japan Society of Radiological Technology, Oct 8, 2015 Invited
-
The 57th annual meeting of American Association of Physicists in Medicine., Jul 12, 2015
-
The 14th Asia-Oceania Congress of Medical Physics, Oct 23, 2014
-
The 13th Asia-Oceania Congress of Medical Physics, Dec 10, 2013
-
The 54th annual meeting of American Association of Physicists in Medicine, Jul 29, 2012
-
The 103rd scientific meeting of Japanese Society of Medical Physics, Apr 13, 2012
-
The 103rd scientific meeting of Japanese Society of Medical Physics, Apr 13, 2012
-
The 53rd annual meeting of American Association of Physicisits in Medicine, Jul, 2011
-
The 101st meeting of Japanese Society of Medical Physics, May, 2011 Invited
-
Japanese Journal of Medical Physics, Sep, 2010
-
The 52nd annual meeting of American Association of Physiccists in Medicine, Jul, 2010
-
Japanese Journal of Medical Physics, Sep, 2009
-
The 19th congress of Japan society of high precision external beam therapy, Jan, 2009 Invited
-
The 4th international meeting of Novalis circle, Jun, 2008
-
The 8th meeting of International Stereotactic Radiosurgery Society, Jun, 2007
-
The 63rd congress of Japanese Society of Radiological Technology, Apr, 2007
-
The 15th meeting of high precision external beam therapy, Mar, 2007
-
The 19th meeting of Japanese Society of Therapeutic Radiation Oncology, Nov, 2006
Teaching Experience
14-
Apr, 2018 - Present国際医学概論 (藤田医科大学)
-
放射線技術学特論 (藤田医科大学)
-
放射線医学概論 (藤田医科大学)
-
放射線機器管理工学特論 (藤田医科大学)
-
放射線診断機器工学実験 (藤田医科大学)
Professional Memberships
8Research Projects
9-
Grants-in-Aid for Scientific Research Grant-in-Aid for Scientific Research (C), Japan Society for the Promotion of Science, Apr, 2022 - Mar, 2025
-
科学研究費助成事業 基盤研究(C), 日本学術振興会, Apr, 2022 - Mar, 2025
-
Grants-in-Aid for Scientific Research Grant-in-Aid for Scientific Research (C), Japan Society for the Promotion of Science, Apr, 2019 - Mar, 2022
-
Grants-in-Aid for Scientific Research Grant-in-Aid for Scientific Research (C), Japan Society for the Promotion of Science, Apr, 2019 - Mar, 2022
-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2016 - Mar, 2019
作成した教科書、教材、参考書
3-
件名(英語)診療放射線技術ガイド(第3版)終了年月日(英語)2014/04概要(英語)共著にて作成。現場で活躍する診療放射線技師にとって必要な実践的な知識を網羅する教科書である。私は放射線治療技術に関する項を担当しました。
-
件名(英語)Japanese standard radiation dosimetry of absorbed dose in water for external radiotherapy開始年月日(英語)2012/09/10概要(英語)本邦の外部放射線治療における吸収線量の標準的計測法を記述する本を医学物理学会の編集メンバーとともに分担執筆した.私はラジオクロミックフィルムの章と光子線計測に関する部分を担当した.
-
件名(英語)Experiment on radiological technology: basic course開始年月日(英語)2016/04/01概要(英語)診療放射線技師を養成する大学において学生実験を行うための教科書を分担執筆した.私はラジオクロミックフィルムを用いた線量計測を担当した.