分子イメージング学分野
Profile Information
- Affiliation
- Fujita Health University
- Degree
- 博士(医学)
- J-GLOBAL ID
- 200901005963740549
- researchmap Member ID
- 1000254979
Research Interests
3Research Areas
1Awards
1Papers
23-
Magnetic resonance imaging, 94 89-97, Sep 9, 2022PURPOSE: As we are exposed to stress on a daily basis, it is important to detect and treat stress during the subclinical period. However, methods to quantify and confirm stress are currently unavailable, and the detection of subclinical stressors is difficult. This study aimed to determine whether manganese-enhanced magnetic resonance imaging (MEMRI) could be used to assess stress in rat brains. METHODS: We exposed male Wistar/ST rats bred in a specific pathogen-free environment to ultrasound stimuli (22 kHz and 55 kHz) for 10 days and then assessed brain activities using MEMRI, the light/dark box test, and ΔFosB immunohistochemical staining. RESULTS: In the MEMRI assessments, exposure at 22 kHz activated the periaqueductal gray, while exposure at 55 kHz specifically enhanced activity in the nucleus accumbens core and the orbitofrontal cortex. The exploratory behavior of the 55-kHz group increased sharply, while that of the 22-kHz group showed a lower exploratory value. ΔFosB expression increased in the orbitofrontal cortex, nucleus accumbens, periaqueductal gray, and amygdaloid nucleus in the 22-kHz group. CONCLUSION: Ultrasound stimuli at 22 kHz suppressed weight gain in rats and excessive ΔFosB induction in the nucleus accumbens caused excessive sensitization of the neural circuit, thereby contributing to pathological behavior. We thus demonstrated that MEMRI can be useful to objectively assess the pathophysiology of stress-related disorders.
-
Physical and Engineering Sciences in Medicine., 44(2) 365-375, Feb, 2021 Peer-reviewed
-
Nuclear medicine communications, 40(8) 792-801, Aug, 2019 Peer-reviewedLead authorBACKGROUND: Single-photon emission computed tomography is a tomographic imaging method that acquires a projection image by rotating a gamma camera around by 380° or 180°. For myocardial single-photon emission computed tomography, 180° acquisition is common, but it has limitations including an incomplete reconstruction, which can distort the resulting image. It is possible to produce a complete reconstruction using 360° acquisition, but the testing time is long and is burdensome to patients. METHODS: The nonuniform sampling pitch acquisition (NUSPA) method devised in this study involves reducing the total sampling count using NUSPA that reduces the sampling pitch in the range in which the gamma cameras are closer to the myocardium (RAO45-LPO45) and increases it elsewhere. RESULTS AND CONCLUSION: The NUSPA-1 method based on a 6° sampling pitch had 20 views fewer than 360° acquisition. In addition, the NUSPA-2 method based on a 3.75° sampling pitch had 60 views fewer than 360° acquisition, considerably reducing the testing time. The acquired sinograms from the NUSPA methods were subjected to nonuniform rational B-spline surface interpolation processing, producing data with a uniform sampling pitch, after which image reconstruction was performed. The images after nonuniform rational B-spline interpolation for both the line sources and heart-liver phantom investigated in this study were not found to have the distortion observed from 180° acquisition or a count decrease at the center, resulting in image quality nearly equivalent to 360° acquisition. This method enabled a reduction in testing time without impacting image quality.
-
Wiley Online Library, Jun, 2019 Peer-reviewed
Misc.
3Books and Other Publications
4Professional Memberships
3Research Projects
1-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2020 - Mar, 2022
教育内容・方法の工夫(授業評価等を含む)
1-
件名(英語)スライドを主体とした講義を行っているが、そのまま聞いているだけでは一方的な講義になってしまうため、重要な項目は空白にして、資料中に書き込むようにしてある。
作成した教科書、教材、参考書
1-
件名(英語)スライドの内容を、重要な項目を空白にして配布している