研究者業績
基本情報
研究分野
1学歴
1-
- 1998年3月
委員歴
17-
2018年10月 - 現在
-
2011年4月 - 現在
-
2008年11月 - 現在
-
2008年4月 - 現在
-
2007年7月 - 現在
受賞
42論文
318-
European radiology 2025年2月4日OBJECTIVE: To directly compare coronary arterial stenosis evaluations by hybrid-type iterative reconstruction (IR), model-based IR (MBIR), deep learning reconstruction (DLR), and high-resolution deep learning reconstruction (HR-DLR) on coronary computed tomography angiography (CCTA) in both in vitro and in vivo studies. MATERIALS AND METHODS: For the in vitro study, a total of three-vessel tube phantoms with diameters of 3 mm, 4 mm, and 5 mm and with simulated non-calcified stepped stenosis plaques with degrees of 0%, 25%, 50%, and 75% stenosis were scanned with area-detector CT (ADCT) and ultra-high-resolution CT (UHR-CT). Then, ADCT data were reconstructed using all methods, although UHR-CT data were reconstructed with hybrid-type IR, MBIR, and DLR. For the in vivo study, patients who had undergone CCTA at ADCT were retrospectively selected, and each CCTA data set was reconstructed with all methods. To compare the image noise and measurement accuracy at each of the stenosis levels, image noise, and inner diameter were evaluated and statistically compared. To determine the effect of HR-DLR on CAD-RADS evaluation accuracy, the accuracy of CAD-RADS categorization of all CCTAs was compared by using McNemar's test. RESULTS: The image noise of HR-DLR was significantly lower than that of others on ADCT and UHR-CT (p < 0.0001). At a 50% and 75% stenosis level for each phantom, hybrid-type IR showed a significantly larger mean difference on ADCT than did others (p < 0.05). At in vivo study, 31 patients were included. Accuracy on HR-DLR was significantly higher than that on hybrid-type IR, MBIR, or DLR (p < 0.0001). CONCLUSION: HR-DLR is potentially superior for coronary arterial stenosis evaluations to hybrid-type IR, MBIR, or DLR shown on CCTA. KEY POINTS: Question How do coronary arterial stenosis evaluations by hybrid-type IR, MBIR, DLR, and HR-DLR compare to coronary CT angiography? Findings HR-DLR showed significantly lower image noise and more accurate coronary artery disease reporting and data system (CAD-RADS) evaluation than others. Clinical relevance HR-DLR is potentially superior to other reconstruction methods for coronary arterial stenosis evaluations, as demonstrated by coronary CT angiography results on ADCT and as shown in both in vitro and in vivo studies.
-
画像診断 45(1) 35-37 2024年12月25日
-
Journal of computer assisted tomography 2024年11月5日OBJECTIVE: The purpose of this study was to compare radiation dose reduction capability for accurate liver tumor measurements of a computer-aided volumetry (CADv) software for filtered back projection (FBP), hybrid-type iterative reconstruction (IR), mode-based iterative reconstruction (MBIR), and deep learning reconstruction (DLR) at a phantom study. METHODS: A commercially available anthropomorphic abdominal phantom was scanned five times with a 320-detector row CT at 600 mA, 400 mA, 200 mA, and 100 mA and reconstructed by four methods. Signal-to-noise ratios (SNRs) of all lesions within the arterial and portal-venous phase inserts were calculated, and SNR of the lesion phantom was compared with that of all reconstruction methods by means of Tukey's honestly significant difference (HSD) test. Then, tumor volume (V) of each nodule was automatically measured using commercially available CADv software. To compare dose reduction capability for each reconstruction method at both phases, mean differences between measured V and standard references were compared by Tukey's honestly significant difference test among the four different reconstruction methods on CT obtained at each of the four tube currents. RESULTS: With each of the tube currents, SNRs for MBIR and DLR were significantly higher than those for FBP and hybrid-type IR (p < 0.05). At the arterial phase, the mean difference in V for the CT protocol obtained at 600 or 100 mA and reconstructed with DLR was significantly smaller than that for others (p < 0.05). At the portal-venous phase, the mean differences in V for the CT protocol obtained at 100 mA and reconstructed with hybrid-type IR, MBIR, and DLR were significantly smaller than that for FBP (p < 0.05). CONCLUSIONS: Findings of our phantom study show that reconstruction method had influence on CADv merits for abdominal CT with not only standard but also reduced dose examinations and that DLR can potentially yield better image quality and CADv measurements than FBP, hybrid-type IR, or MBIR in this setting.
-
Magnetic resonance imaging 110240-110240 2024年9月29日PURPOSE: The purpose of this study was to determine the capability of proton density with fat fraction (PD-FFQ) imaging to help assess hematopoietic ability and diagnose aplastic anemia in adults. METHODS: Between January 2021 and March 2023, patients diagnosed with aplastic anemia (AA: n = 14) or myelodysplastic syndrome (MDS: n = 14) were examined by whole-body PD-FFQ imaging, and 14 of 126 age and gender matched patients who had undergone the same PD-FFQ imaging were selected as control group. All proton density fat fraction (PDFF) index evaluations were then performed by using regions of interest (ROIs). Pearson's correlation was used to determine the relationship between blood test results and each quantitative index, and ROC-based positive test and discrimination analyses to compare capability to differentiate the AA from the non-AA group. Finally, sensitivity, specificity and accuracy of all quantitative indexes were compared by means of McNemar's test. RESULTS: Mean PDFF, standard deviation (SD) and percentage of coefficient of variation (%CV) for vertebrae showed significant correlation with blood test results (-0.52 ≤ r ≤ -0.34, p < 0.05). Specificity (SP) and accuracy (AC) of %CV of PDFF in vertebrae were significantly higher than those of mean PDFF in vertebrae and the posterior superior iliac spine (SP: p = 0.0002, AC: p = 0.0001) and SD of PDFF in vertebrae (SP: p = 0.008, AC: p = 0.008). Moreover, AC of SD of PDFF in vertebrae was significantly higher than that of mean PDFF in vertebrae and the posterior superior iliac spine (p = 0.03). CONCLUSION: Whole-body PD-FFQ imaging is useful for hematopoietic ability assessment and diagnosis of aplastic anemia in adults.
-
Journal of magnetic resonance imaging : JMRI 2024年9月16日
MISC
620-
Journal of magnetic resonance imaging : JMRI 32(6) 1353-69 2010年12月 査読有りThis review compares the emerging technologies and approaches in the application of magnetic resonance (MR) and computed tomography (CT) imaging for the assessment of pulmonary nodules and staging of malignant findings. Included in this review is a brief definition of pulmonary nodules and an introduction to the challenges faced. We have highlighted the current status of both MR and CT for the early detection of lung nodules. Developments are detailed in this review for the management of pulmonary nodules using advanced imaging, including: dynamic imaging studies, dual energy CT, computer aided detection and diagnosis, and imaging assisted nodule biopsy approaches which have improved lung nodule detection and diagnosis rates. Recent advancements linking in vivo imaging to corresponding histological pathology are also highlighted. In vivo imaging plays a pivotal role in the clinical staging of pulmonary nodules through TNM assessment. While CT and positron emission tomography (PET)/CT are currently the most commonly clinically employed modalities for pulmonary nodule staging, studies are presented that highlight the augmentative potential of MR.
-
Journal of nuclear medicine : official publication, Society of Nuclear Medicine 51(10) 1549-58 2010年10月 査読有り(18)F-FDG PET is an established functional imaging modality for the evaluation of human disease. Diffusion-weighted MRI (DWI) is another rapidly evolving functional imaging modality that can be used to evaluate oncologic and nononcologic lesions throughout the body. The information provided by (18)F-FDG PET and DWI can be complementary, because the 2 methods are based on completely different biophysical underpinnings. This article will describe the basic principles, clinical applications, and limitations of DWI. In addition, the available evidence that correlates and compares (18)F-FDG PET and DWI will be reviewed.
-
産婦人科治療 101(3) 264-275 2010年9月女性骨盤に生じる腫瘤性病変は多種多様であり、まずその由来臓器の特定が骨盤画像診断をするうえで重要である。卵巣には多くの疾患が見られ、とくに卵巣腫瘍の画像所見は良悪性にかかわらず非常に多彩である。本項では、卵巣腫瘤に類似する疾患をいくつか供覧し、各々の画像的特徴について概説する。(著者抄録)
-
INNERVISION 25(9) 20-23 2010年8月
-
INNERVISION 25(2) 83-87 2010年1月1972年のG.N.HounsfieldらによるCT開発以来、CTの技術の進歩には目覚しいものがある。特に99年の4列multi detector-row CT(MDCT)の登場により、CT検査の内容が飛躍的に向上し、その後の検出器列数の増加により、16列、32列あるいは64列MDCTが開発・臨床応用されてきた。さらに、現在では64列MDCTを超えた性能を発揮するMDCTとして、128列以上の検出器を有し、128〜256スライスの撮影を可能とするMDCTや、X線管と検出器の組み合わせを2系統有するDual Energy CT、320列面検出器型CT(Area Detector CT:ADCT)などが臨床応用されつつある。本稿のテーマであるADCTは、0.35もしくは0.5s/rotの管球回転速度を有し、1回転での撮影範囲は体軸方向で最大16cm(0.5mm×320列)であるため、16cm以下の範囲ではhelical scanを必要としない。このため、寝台を移動することなく、X、Y、Z軸においてそれぞれの空間分解能が同等の体積データであるisotoropic voxelデータを、各ボクセルにおける時間差なく取得可能である。これにより、心臓領域では1心拍で心臓全体をカバーすることができ、心臓CT領域でしばしば問題となっていた不整脈の問題などを大幅に改善することができるようになった。また、頭部領域では、連続あるいは間歇的に一定の撮影範囲を寝台移動なくdynamic scanを行うdynamic volume scanにより、脳全体を経時的に撮影することで、1分以下の撮影で脳血管の動・静脈の3D、4D画像に加え、脳全体の灌流画像(perfusion image)が得られるようになった。最近では、ADCTを用いた有用性も報告され始めている。一方、胸部や腹部領域などの広範囲な撮影に関しては、心臓や頭部と異なり、ADCTにおいても1回転で撮影範囲全体をカバーするのは不可能であるため、helical scanを行うか、16cm以下の撮影をStep & Shoot方式で行うwide volume scanにて撮影することになる。ADCTにおいて、helical scanを行う場合には従来の64列MDCTとしての性能を有するため、特筆すべき点はないものの、wide volume scanによる撮影を行った場合には、各ボリュームデータ間のつなぎ目の位置およびCT値のズレや、各ボリュームデータ間での造影タイミングのズレによる造影剤の濃度差を生じてしまうなどの課題点もある。ただし、面検出器型という特性を生かした撮影により、helical scanにない情報を得られるのも事実である。本稿では、ADCTの胸部領域の撮影において実際の症例を提示しながら、特に通常の造影CTにおける造影剤注入法の工夫と肺結節における灌流画像(perfusion image)を中心に述べる。(著者抄録)
-
INNERVISION 24(12) 106-107 2009年11月
書籍等出版物
25講演・口頭発表等
800-
The 6th International Congress on Magnetic Resonance Imaging (ICMRI 2018) and 23rd Scientific Meeting of KSMRM 2018年3月 Korean Society of Magnetic Resonance in Medicine
担当経験のある科目(授業)
1-
イメージング (神戸大学)
所属学協会
18共同研究・競争的資金等の研究課題
20-
日本学術振興会 科学研究費助成事業 2023年4月 - 2026年3月
-
日本学術振興会 科学研究費助成事業 2022年4月 - 2025年3月
-
日本学術振興会 科学研究費助成事業 2021年4月 - 2024年3月
-
日本学術振興会 科学研究費助成事業 2020年4月 - 2023年3月
-
日本学術振興会 科学研究費助成事業 2018年4月 - 2022年3月