研究者業績
基本情報
- 所属
- 藤田医科大学 医学部 医学科 教授 (講座教授(主任教授))
- 学位
- 博士(医学)(1998年3月 神戸大学)
- 連絡先
- yohno
fujita-hu.ac.jp - ORCID ID
https://orcid.org/0000-0002-4431-1084- J-GLOBAL ID
- 200901037501461104
- researchmap会員ID
- 1000372100
研究キーワード
6経歴
3-
2023年6月 - 現在
-
2019年4月 - 2023年5月
-
2012年4月 - 2019年3月
学歴
1-
- 1998年3月
委員歴
28-
2024年10月 - 現在
-
2024年6月 - 現在
-
2022年9月 - 現在
-
2020年9月 - 現在
受賞
42論文
349-
Journal of Magnetic Resonance Imaging 2026年6月
-
Japanese journal of radiology 2026年5月20日PURPOSE: Since the clinical application of computed tomography (CT), cardiac and respiratory motion artifacts have caused decreased image quality and reduced detection or quantitative or qualitative evaluation of lung parenchymal or vascular abnormalities on chest CT with lung window settings in patients with pulmonary diseases. Recently, a deep learning (DL)-based motion correction algorithm (CLEAR Motion) has been developed and clinically used for chest CT. We hypothesized that CLEAR Motion can significantly reduce motion artifacts on chest CT examinations relative to conventional chest CT images reconstructed without CLEAR Motion. The purpose of this study was to determine the utility of CLEAR Motion for image quality improvement in chest CT with lung window settings in patients with various pulmonary diseases. MATERIALS AND METHODS: Fifty-six consecutive patients with various thoracic diseases underwent non-electrocardiogram-gated chest helical CT examination using a 320-detector row CT and underwent reconstruction using the conventional reconstruction method and CLEAR Motion. To compare the quantitative image quality, the cardio-pulmonary edge distance (CPED) and slope (CPES) were measured on each CT scan in the axial plane. Comparing cardiac motion reduction capability, overall image quality, cardiac motion artifact, and region conspicuity were visually assessed in the lung window setting on the axial, coronal, and sagittal planes. The paired t-test and Wilcoxon signed-rank test were then performed. RESULTS: The CPEDs and CPESs of the entire lung and left lung on CT with CLEAR Motion were significantly superior to those of CT without CLEAR Motion (p < 0.001). The overall image quality, cardiac motion artifact, and region conspicuity on CT with CLEAR Motion were significantly higher than those without CLEAR Motion on each plane (p < 0.001). CONCLUSION: The DL-based motion correction algorithm named as 'CLEAR Motion' has a potential to improve image quality on chest CT with lung window setting in patients with pulmonary diseases.
-
Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine 2026年4月24日PURPOSE: To evaluate whether reverse encoding distortion correction (RDC) improves image quality and maintains apparent diffusion coefficient (ADC) measurements in diffusion-weighted imaging (DWI) on female pelvic MRI using a 1.5-T in in vitro and in vivo studies. METHODS: This retrospective, institutional review board-approved study included both in vitro and in vivo analyses of 31 women (mean age, 41 ± 15 years; range, 24-80 years) who underwent pelvic MRI between January and March 2022. T2-weighted image (T2WI) and DWI with and without RDC were acquired, and ADC maps were generated. Quantitative metrics included SNR, contrast-to-noise ratio (CNR), ADC values, and deformation ratio (DR), defined as the proportional area discrepancy between DWI and T2WI for the uterine corpus, cervix, ovary, and lesions. Qualitative assessments-overall image quality (OIQ), deformation severity (DS), and diagnostic confidence level (DCL)-were independently scored by 2 blinded radiologists using 5-point scales. RESULTS: In vitro SNR and ADC values showed no significant differences between DWI with and without RDC, with strong correlations to reference measurements (ρ = 0.99, P < 0.001). In vivo, SNR, CNR, and ADC values of the myometrium, cervix, and ovary did not differ significantly between 2 methods (P > 0.05). DRs were significantly lower in DWI with RDC than in DWI without RDC (P ≤ 0.0003). ADC values showed strong correlations between DWI with and without RDC on uterine corpus, cervix, ovary and lesions (ρ = 0.82-0.90, P < 0.001). Qualitative scores improved with RDC: higher OIQ (P = 0.0004), lower DS (P = 0.0004), and higher DCL (P = 0.03). Interobserver agreement ranged from substantial to almost perfect (κ = 0.78-0.97). CONCLUSION: RDC improves image quality and reduces image distortion in DWI on female pelvic MRI at a 1.5-T, while maintaining ADC measurements in in vitro and in vivo settings.
-
Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine 2026年4月10日PURPOSE: The present study directly compared the quantitative capabilities of regional perfusion and pulmonary functional change assessments among electrocardiography (ECG)- and photoplethysmography (PPG)-monitored phase-resolved functional lung (PREFUL) MRI and dynamic contrast-enhanced (CE) perfusion MRI in thoracic oncologic patients. METHODS: Seventeen thoracic oncologic patients prospectively underwent ECG- and PPG-monitored PREFUL MRI, dynamic CE-perfusion MRI, and pulmonary function tests. ECG- and PPG-monitored perfusion-weighted PREFUL MRI (PW-MRI) and quantitative perfusion maps from dynamic CE-perfusion MRI were generated. Regional perfusions were determined using ROI measurements. For each patient, the overall perfusion from each method was determined as the average ROI measurement value. To determine the relationship between regional perfusion among all methods, Pearson's correlations were performed. Tukey's honest significant difference test was performed to compare regional perfusion among ventral, middle, and dorsal slice positions on ECG- and PPG-monitored PW-MRI and quantitative perfusion maps. To assess the pulmonary functional loss evaluation capability of each MRI method, each overall perfusion was correlated with %VC and %FEV1 using Pearson's correlation. RESULTS: The correlation of regional perfusion between ECG- and PPG-monitored PW-MRI was significant and good (r = 0.79, P < 0.0001). However, the correlations between ECG- or PPG-monitored PW-MRI and quantitative perfusion maps were assessed as significant and fair (ECG: r = 0.4, P < 0.0001; PPG: r = 0.36, P < 0.0001). ECG- and PPG-monitored PW-MRI demonstrated significantly higher perfusion than the quantitative perfusion map (P < 0.0001). Furthermore, ECG-and PPG-monitored PW-MRI and quantitative perfusion maps had significant and moderate correlations (%VC: 0.60 ≤ r ≤ 0.63, P < 0.05; %FEV1: 0.52 ≤ r ≤ 0.69, P < 0.05). CONCLUSION: ECG- and PPG-monitored PREFUL MRI had similar potential to dynamic CE-perfusion MRI for quantitatively assessing regional perfusion and pulmonary functional changes in thoracic oncologic patients. Furthermore, PPG-monitored PREFUL MRI showed little difference in regional perfusion evaluation compared with ECG-monitored PREFUL MRI and the potential to play a complementary role in this setting.
MISC
644-
画像診断 16(9) 1027-1031 1996年9月68歳女.1983年6月,検診にて右胸水を指摘され,放射線科を受診,経過観察していたが改善傾向無いため,1985年2月試験開胸術が施行され病理学的に胸膜炎と診断された.1992年9月頃,右鼠径部膨隆を自覚し,12月試験開腹が施行され,下腹部腹壁直下に鶏卵大の腫瘤を認め,腹膜の悪性中皮腫と診断され,腫瘤は摘出された.同時にX線写真上右肋骨横隔膜に異常陰影がみられた.入院後CTガイド下経皮的肺生検を施行し,悪性中皮腫と診断され,1993年2月肺下葉,横隔膜合併切除が施行された
-
肺癌 36(4) 393-399 1996年8月肺癌脳転移症例におけるCTとMRIの転移巣の検出能について検討した. 1)CTで病巣が検出できてMRIで検出できなかった例はなかった. 2)特にテント下病巣及び小転移巣においてはMRIはCTと比較して有意に優れていた
-
臨床放射線 41(1) 7-12 1996年1月1)中枢気管支病変に三次元CT表示を行い,粘膜面や腫瘍表面性状の描出能を評価した. 2)ファントムによる撮像法及び再構成法の検討では描出能は1/1/1が最も描出能に優れていたが,テーブル移動速度2mm/secでも概ね良好であった. 3)臨床例の検討では粘膜主体型14例中12例に腫瘍の表面性状が気管支鏡所見とほぼ相関し,表層浸潤型の2例も粘膜の不整像が描出された. 4)粘膜下主体型8例中6例に粘膜面の性状が気管支鏡所見とほぼ相関し,粘膜面の不整を伴った上皮下型と粘膜面が平滑な壁内或いは壁外型と鑑別が可能であった. 5)三次元CT表示による腫瘍表面や粘膜面の性状がほぼ気管支鏡所見と一致した例は22例中18例であった
-
肺癌 35(7) 883-890 1995年12月20日ヘリカルCTを用いた肺癌2次検診を行い, 導入当初より4年間の2次検診受診者389名中の要精検受診者49名につき, 臨床所見並びに間接, 直接X線写真との描出能を対比検討した.49例中, 悪性例は18例であった.17例は気管支鏡やCT下肺生検で診断された.残り1例は経過観察とした症例で, 経過観察中9ヵ月後に増大を認め, 開胸肺生検で肺癌と診断された.径1cm未満の生検困難例(10例)は全例経過観察(2〜22ヵ月)としたが, いずれも増大傾向はなかった.またX線写真では読影困難で, CTで初めて腫瘤影を発見された症例は, 間接写真で7例, 直接写真で9例あった.悪性腫瘍は全例, X線写真とCTで読影可能であった.要精検例の中には, 侵襲的生検を行わずに経過観察で対処できる例も多いと考える.また今回, CTで初めて発見された肺癌例はなく, ヘリカルCTによる2次検診の有用性については, さらに検討が必要である.
書籍等出版物
25講演・口頭発表等
800-
The 6th International Congress on Magnetic Resonance Imaging (ICMRI 2018) and 23rd Scientific Meeting of KSMRM 2018年3月 Korean Society of Magnetic Resonance in Medicine
担当経験のある科目(授業)
1-
イメージング (神戸大学)
所属学協会
18共同研究・競争的資金等の研究課題
22-
日本学術振興会 科学研究費助成事業 2025年4月 - 2028年3月
-
日本学術振興会 科学研究費助成事業 2025年4月 - 2028年3月
-
日本学術振興会 科学研究費助成事業 2023年4月 - 2026年3月
-
日本学術振興会 科学研究費助成事業 2022年4月 - 2025年3月
-
日本学術振興会 科学研究費助成事業 2021年4月 - 2024年3月