Curriculum Vitaes
Profile Information
- Affiliation
- Professor (Professor and Chairman), School of Medicine, Faculty of Medicine, Fujita Health University
- Degree
- MD, PhD(Mar, 1998, Kobe University Graduate School of Medicine)
- Contact information
- yohno
fujita-hu.ac.jp - ORCID ID
https://orcid.org/0000-0002-4431-1084- J-GLOBAL ID
- 200901037501461104
- researchmap Member ID
- 1000372100
Research Interests
6Research Areas
2Research History
3-
Apr, 2019 - May, 2023
-
Apr, 2012 - Mar, 2019
Education
1-
- Mar, 1998
Committee Memberships
28-
Oct, 2024 - Present
-
Jun, 2024 - Present
-
Sep, 2022 - Present
-
Sep, 2020 - Present
Awards
42Papers
353-
Respiratory Investigation, Sep, 2026
-
Japanese Journal of Radiology, Aug 29, 2026
-
Journal of Magnetic Resonance Imaging, Jun, 2026
-
Japanese journal of radiology, May 20, 2026PURPOSE: Since the clinical application of computed tomography (CT), cardiac and respiratory motion artifacts have caused decreased image quality and reduced detection or quantitative or qualitative evaluation of lung parenchymal or vascular abnormalities on chest CT with lung window settings in patients with pulmonary diseases. Recently, a deep learning (DL)-based motion correction algorithm (CLEAR Motion) has been developed and clinically used for chest CT. We hypothesized that CLEAR Motion can significantly reduce motion artifacts on chest CT examinations relative to conventional chest CT images reconstructed without CLEAR Motion. The purpose of this study was to determine the utility of CLEAR Motion for image quality improvement in chest CT with lung window settings in patients with various pulmonary diseases. MATERIALS AND METHODS: Fifty-six consecutive patients with various thoracic diseases underwent non-electrocardiogram-gated chest helical CT examination using a 320-detector row CT and underwent reconstruction using the conventional reconstruction method and CLEAR Motion. To compare the quantitative image quality, the cardio-pulmonary edge distance (CPED) and slope (CPES) were measured on each CT scan in the axial plane. Comparing cardiac motion reduction capability, overall image quality, cardiac motion artifact, and region conspicuity were visually assessed in the lung window setting on the axial, coronal, and sagittal planes. The paired t-test and Wilcoxon signed-rank test were then performed. RESULTS: The CPEDs and CPESs of the entire lung and left lung on CT with CLEAR Motion were significantly superior to those of CT without CLEAR Motion (p < 0.001). The overall image quality, cardiac motion artifact, and region conspicuity on CT with CLEAR Motion were significantly higher than those without CLEAR Motion on each plane (p < 0.001). CONCLUSION: The DL-based motion correction algorithm named as 'CLEAR Motion' has a potential to improve image quality on chest CT with lung window setting in patients with pulmonary diseases.
Misc.
644Books and Other Publications
25Presentations
800-
第39回日本磁気共鳴医学会総会, Sep, 2011, 日本磁気共鳴医学会
-
第39回日本磁気共鳴医学会大会, Sep, 2011, 日本磁気共鳴医学会
-
STROKE2011(第36回日本脳卒中学会総会、第40回日本脳卒中の外科学会、第27回スパズム・シンポジウム), Aug, 2011, 日本脳卒中学会、日本脳卒中の外科学会、スパズム・シンポジウム
-
Joint Meeting of ESTI and the Fleischner Society, Jun, 2011, European Society of Thoracic Imaging, Fleischner Society
-
19th Annual Meeting of ISMRM 2011, May, 2011, 国際核磁気共鳴医学会
-
第3回アジア腹部放射線研究会, May, 2011, アジア腹部放射線研究会
-
The 2nd Asian Congress of Thoracic Radiology, May, 2011
-
ACTR 2011, The 2nd Asian Congress of Thoracic Radiology, May, 2011, アジア胸部放射線学会
-
第3回アジア腹部放射線研究会, May, 2011, アジア腹部放射線研究会
-
The 2nd Asian Congress of Thoracic Radiology, May, 2011, Asian Congress of Thoracic Radiology
-
European Congress of Radiology 2011, Mar, 2011, European Society of Radiology
-
ECR 2011, Mar, 2011, European Society of Radiology Invited
-
Joint Meeting combining the 3rd Japanese Society of Pulmonary Functional Imaging and 5th International Workshop for Pulmonary Functional Imaging, Jan, 2011, 日本呼吸機能イメージング研究会 Invited
-
第3回呼吸機能イメージング研究会学術集会・第5回肺機能イメージング国際ワークショップ(共催), Jan, 2011, 日本呼吸機能イメージング研究会
-
RSNA2010, Nov, 2010, Radiological Society of North America
-
RSNA2010, Nov, 2010, Radiological Society of North America
-
96th Scientific Assemmbly and Annual Meeting of Radiological Society of North America, Nov, 2010, Radiological Society of North America
-
96th Scientific Assemmbly and Annual Meeting of Radiological Society of North America, Nov, 2010, Radiological Society of North America
Teaching Experience
1-
イメージング (神戸大学)
Professional Memberships
18Research Projects
22-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2025 - Mar, 2028
-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2025 - Mar, 2028
-
科学研究費助成事業, 日本学術振興会, Apr, 2023 - Mar, 2026
-
科学研究費助成事業, 日本学術振興会, Apr, 2022 - Mar, 2025
-
科学研究費助成事業, 日本学術振興会, Apr, 2021 - Mar, 2024