研究者業績
基本情報
- 所属
- 藤田医科大学 医学部 医学科 教授 (講座教授(主任教授))
- 学位
- 博士(医学)(1998年3月 神戸大学)
- 連絡先
- yohno
fujita-hu.ac.jp - ORCID ID
https://orcid.org/0000-0002-4431-1084- J-GLOBAL ID
- 200901037501461104
- researchmap会員ID
- 1000372100
研究キーワード
6経歴
3-
2023年6月 - 現在
-
2019年4月 - 2023年5月
-
2012年4月 - 2019年3月
学歴
1-
- 1998年3月
委員歴
28-
2024年10月 - 現在
-
2024年6月 - 現在
-
2022年9月 - 現在
-
2020年9月 - 現在
受賞
42論文
336-
Radiology: Cardiothoracic Imaging 2025年10月1日
-
European Radiology 2025年5月22日
-
European radiology 2025年2月4日OBJECTIVE: To directly compare coronary arterial stenosis evaluations by hybrid-type iterative reconstruction (IR), model-based IR (MBIR), deep learning reconstruction (DLR), and high-resolution deep learning reconstruction (HR-DLR) on coronary computed tomography angiography (CCTA) in both in vitro and in vivo studies. MATERIALS AND METHODS: For the in vitro study, a total of three-vessel tube phantoms with diameters of 3 mm, 4 mm, and 5 mm and with simulated non-calcified stepped stenosis plaques with degrees of 0%, 25%, 50%, and 75% stenosis were scanned with area-detector CT (ADCT) and ultra-high-resolution CT (UHR-CT). Then, ADCT data were reconstructed using all methods, although UHR-CT data were reconstructed with hybrid-type IR, MBIR, and DLR. For the in vivo study, patients who had undergone CCTA at ADCT were retrospectively selected, and each CCTA data set was reconstructed with all methods. To compare the image noise and measurement accuracy at each of the stenosis levels, image noise, and inner diameter were evaluated and statistically compared. To determine the effect of HR-DLR on CAD-RADS evaluation accuracy, the accuracy of CAD-RADS categorization of all CCTAs was compared by using McNemar's test. RESULTS: The image noise of HR-DLR was significantly lower than that of others on ADCT and UHR-CT (p < 0.0001). At a 50% and 75% stenosis level for each phantom, hybrid-type IR showed a significantly larger mean difference on ADCT than did others (p < 0.05). At in vivo study, 31 patients were included. Accuracy on HR-DLR was significantly higher than that on hybrid-type IR, MBIR, or DLR (p < 0.0001). CONCLUSION: HR-DLR is potentially superior for coronary arterial stenosis evaluations to hybrid-type IR, MBIR, or DLR shown on CCTA. KEY POINTS: Question How do coronary arterial stenosis evaluations by hybrid-type IR, MBIR, DLR, and HR-DLR compare to coronary CT angiography? Findings HR-DLR showed significantly lower image noise and more accurate coronary artery disease reporting and data system (CAD-RADS) evaluation than others. Clinical relevance HR-DLR is potentially superior to other reconstruction methods for coronary arterial stenosis evaluations, as demonstrated by coronary CT angiography results on ADCT and as shown in both in vitro and in vivo studies.
MISC
621書籍等出版物
25講演・口頭発表等
800-
The 6th International Congress on Magnetic Resonance Imaging (ICMRI 2018) and 23rd Scientific Meeting of KSMRM 2018年3月 Korean Society of Magnetic Resonance in Medicine
担当経験のある科目(授業)
1-
イメージング (神戸大学)
所属学協会
18共同研究・競争的資金等の研究課題
22-
日本学術振興会 科学研究費助成事業 2025年4月 - 2028年3月
-
日本学術振興会 科学研究費助成事業 2025年4月 - 2028年3月
-
日本学術振興会 科学研究費助成事業 2023年4月 - 2026年3月
-
日本学術振興会 科学研究費助成事業 2022年4月 - 2025年3月
-
日本学術振興会 科学研究費助成事業 2021年4月 - 2024年3月