医学部
Profile Information
- Affiliation
- School of Medicine Faculty of Medicine, Fujita Health University
- Degree
- 博士(理学)(名古屋大学)
- J-GLOBAL ID
- 200901003971539256
- researchmap Member ID
- 6000001840
Research Interests
8Research Areas
4Research History
1Papers
24-
Journal of Astronomical Telescopes, Instruments, and Systems, 4(2), Apr 1, 2018 Peer-reviewedThe Soft X-ray Spectrometer onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3-To 12-keV band. Extensive preflight calibration measurements are the basis for our modeling of the pulse height-energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse height-energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsar wind nebulae to validate our models of the telescope area and detector efficiency and to derive a more accurate value for the thickness of the gate-valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab nebula to refine the pixel-To-pixel timing and validate the absolute timing.
-
Journal of Astronomical Telescopes, Instruments, and Systems, 4(2), Apr, 2018 Peer-reviewed© The Authors. The Hitomi (ASTRO-H) mission is the sixth Japanese x-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E > 2 keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft x-rays to gamma rays. After a successful launch on February 17, 2016, the spacecraft lost its function on March 26, 2016, but the commissioning phase for about a month provided valuable information on the onboard instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month.
-
PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 70(2), Mar, 2018 Peer-reviewedWe present results of inflight calibration of the point spread function of the Soft X-ray Telescope that focuses X-rays onto the pixel array of the Soft X-ray Spectrometer system. We make a full array image of a point-like source by extracting a pulsed component of the Crab nebula emission. Within the limited statistics afforded by an exposure time of only 6.9 ks and limited knowledge of the systematic uncertainties, we find that the raytracing model of 1.'2 half-power-diameter is consistent with an image of the observed event distributions across pixels. The ratio between the Crab pulsar image and the raytracing shows scatter from pixel to pixel that is 40% or less in all except one pixel. The pixel-to-pixel ratio has a spread of 20%, on average, for the 15 edge pixels, with an averaged statistical error of 17% (1 sigma). In the central 16 pixels, the corresponding ratio is 15% with an error of 6%.
-
PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 70(2), Mar, 2018 Peer-reviewed
-
PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 70(2), Mar, 2018 Peer-reviewedWe describe the in-orbit performance of the soft X-ray imaging system consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi. Verification and calibration of imaging and spectroscopic performance are carried out, making the best use of the limited data of less than three weeks. Basic performance, including a large field of view of 38' x 38', is verified with the first-light image of the Perseus cluster of galaxies. Amongst the small number of observed targets, the on-minus-off pulse image for the out-of-time events of the Crab pulsar enables us to measure the half-power diameter of the telescope as similar to 1.'3. The average energy resolution measured with the onboard calibration source events at 5.89 keV is 179 +/- 3 eV in full width at half maximum. Light leak and crosstalk issues affected the effective exposure time and the effective area, respectively, because all the observations were performed before optimizing an observation schedule and the parameters for the dark-level calculation. Screening the data affected by these two issues, we measure the background level to be 5.6 x 10(-6) counts s(-1) arcmin(-2) cm(-2) in the energy band of 5-12 keV, which is seven times lower than that of the Suzaku XIS-BI.
Teaching Experience
1-
物理学 (藤田保健衛生大学)