研究者業績
基本情報
MISC
86-
Proceeding of 20th East Asia Conference of Radiological Technologist 36 2013年 査読有り
-
Proceeding of The 19 th Asia and Australasia Conference of Radiographers and Radiological Technologists 97 2013年 査読有り
-
Proceeding of The 28th Singapore - Malaysia Radiographer's Conference 78 2013年
-
Proceeding of The 28th Singapore - Malaysia Radiographer's Conference 76 2013年
-
Proceeding of The 28th Singapore - Malaysia Radiographer's Conference 75 2013年
-
Proceeding of The 28th Singapore - Malaysia Radiographer's Conference 69 2013年
-
Proceeding of The 28th Singapore - Malaysia Radiographer's Conference 68 2013年
-
Proceeding of The 28th Singapore - Malaysia Radiographer's Conference 25 2013年
-
Proceeding of 2012 KIMES & Seoul Radiological Technologists Associaciation Annual Conference 110 2012年 査読有り
-
Proceeding of The Korean Radiological Technologists Association 33 13 2012年
-
Proceeding of International Session of 28th Japan Association of Radiological Technologists Conference 140 2012年
-
Proceeding of International Session of 28th Japan Association of Radiological Technologists Conference 139 2012年
-
Proceeding of International Session of 28th Japan Association of Radiological Technologists Conference 139 2012年
-
Proceeding of Journal of Radiologic Science and Medical Imaging 33 19 2012年
-
Proceeding of Journal of Radiologic Science and Medical Imaging 33 16 2012年
-
Proceeding of Journal of Radiologic Science and Medical Imaging 33 14 2012年
-
Proceeding of Journal of Radiologic Science and Medical Imaging 33 12 2012年
-
Proceeding of Journal of Radiologic Science and Medical Imaging 33 13 2012年
-
医用画像情報学会 29(4) 105-108 2012年In magnetic resonance imaging (MRI) , signal intensity is dependent on the substances in a voxel. The signal is decayed when Air gap is present. In addition to that, the presence of Air gap creates a local inhomogeneity in a magnetic field, causing artifact on MR images. <br>Consequently, it is said that the influence of Air gap is less in fast spin-echo (FSE) sequences than spinecho (SE) sequences. We analyzed the effect of air on slice profiles of both SE sequences and FSE sequences in numerical simulation with Bloch equations. As a result, we confirmed that slice profile is more distorted in FSE sequences compared to SE sequences.
-
Proceeding of 18th Asia Australasia Conference of Radiological technologists 152 2011年 査読有り
-
Proceeding of 2011 KIMES & Seoul Radiological Technologists Associaciation Annual Conference 122 2011年 査読有り
-
日本放射線技術学会 67(4) 328-335 2011年 査読有りFollowing the trend of the digitalization of the modalities used for diagnostic imaging, the devices for such imaging have increasingly included monitors. The present study was undertaken to evaluate the usefulness of soft-copy (liquid crystal display; LCD) images of phantoms of small adenocarcinomas using receiver operating characteristic (ROC) analysis of two different display systems: LCD and hard copy (film). A two-tailed paired t-test and the jackknife method (parametric methods) were performed, and no significant differences were found in the area under the ROC curve (AUC) for the pulmonary fields, lungs, ribs, or mediastinum between the film and LCD display systems, and the detectability did not differ between the film and LCD monitors. A Mann-Whitney U test, which is a non-parametric method that applies to the analysis of a small sample, also showed no significant differences in the AUC. The results of this study suggest that LCDs can replace hard-copy film as a display system if the signals.
-
医用画像情報学会 28(2) 41-45 2011年 査読有りThe recent increase in the incidence of SAR and fever contracted during medical examinations has raised concerns about transmission from the WB coil used during magnetic resonance imaging(MRI)using SENSE. We measured changes in temperature at the body surface during MRI medical examinations using T2 Fast Spin Echo(T2FSE)and Hahn T2 Fast Spin Echo(Hahn-T2FSE). We initially calibrated the thermometer in an incubator and confirmed that it operated normally in a high magnetic field and that it was not damaged or influenced by heat generated by RF pulses. All experiments were performed using an Excel ART Pianissimo 1.0T(Toshiba Medical Systems)and Thermo clone SL type(KN Laboratories). The temperature at the body surface changed according to the measurement point. The temperature increase was lower when measured with Hahn-T2FSE than with T2FSE. One limitation of this study was that temperature was measured only during 1.0 T MRI.
-
生体医工学 49(1) 241-244 2011年 査読有りIn general, the sinc function is the standard RF pulse employed in MRI studies. In the present study, we experimentally produced “the original function” by extending the Fourier cosine transform to the sinc-Gaussian function. Theoretic slice profiles obtained using the original function showed a greater improvement in the rectangular shape compared with the sinc function. As to the physical evaluation performed with 1T-MRI clinical equipment, the suppressed decrease in Contrast to Noise Ratio was higher with the original function than the sinc function in the volunteer head image multi-slice evaluation. Thus, all the results from the simulation and the clinical equipment evaluation demonstrate that the original function can improve the quality of MRI images even with shorter Echo Time.
-
Proceeding of 26th Singapore-Malaysia Radiographers' Conference 2011年
-
Proceeding of 16th The East Asia Conference of Radiological Technologists 63 2010年 査読有り
-
Proceeding of 16th The East Asia Conference of Radiological Technologists 62 2010年 査読有り
-
Proceeding of 16th The East Asia Conference of Radiological Technologists 61 2010年 査読有り
-
Proceeding of 16th The East Asia Conference of Radiological Technologists 60 2010年 査読有り
-
MAGNETIC RESONANCE IN MEDICAL SCIENCES 9(3) 119-129 2010年 査読有りPurpose: q-ball imaging (QBI) reconstructs the orientation distribution function (ODF) that describes the probability for a spin to diffuse in a given direction, and it is capable of identifying intravoxel multiple fiber orientations. The local maxima of ODF are assumed to indicate fiber orientations, but there is a mismatch between the orientation of a fiber crossing and the local maxima. We propose a novel method, multi-shelled QBI (MS-QBI), that gives a new ODF based on the moment of the probability density function of diffusion displacement. We test the accuracy of the fiber orientation indicated by the new ODF and test fiber tracking using the new ODF. Methods: We performed tests using numerical simulation. To test the accuracy of fiber orientation, we assumed that 2 fibers cross and evaluated the deviation of the measured crossing angle from the actual angle. To test the fiber tracking, we used a numerical phantom of the cerebral hemisphere containing the corpus callosum, projection fibers, and superior longitudinal fasciculus. In the tests, we compared the results between MS-QBI and conventional QBI under the condition of approximately equal total numbers of diffusion signal samplings between the 2 methods and chose the interpolation parameter such that the stabilities of the results of the angular deviation for the 2 methods were the same. Results: The absolute value of the mean angular deviation was smaller in MS-QBI than in conventional QBI. Using the moment-based ODF improved the accuracy of fiber pathways in fiber tracking but maintained the stability of the results. Conclusion: MS-QBI can more accurately identify intravoxel multiple fiber orientations than can QBI, without increasing sampling number. The high accuracy of MS-QBI will contribute to the improved tractography.
-
Proceeding of 13th The East Asia Conference of Radiological Technologists 88/1-88/2 2009年 査読有り
-
Conference of Radiological Technologists 87-88 2009年 査読有り
-
Proceeding of 2009 KIMES & Seoul Radiological Technologists Association annual Coference 122-123 2009年 査読有り
-
Proceeding of 13th The East Asia Conference of Radiological Technologists 83-84 2009年 査読有り
-
Proceeding of 13th The East Asia Conference of Radiological Technologists 85-86 2009年
-
Proceeding of 10th The East Asia Conference of Radiological Technologists 89-90 2008年 査読有り
-
Proceeding of 10th The East Asia Conference of Radiological Technologists 86-87 2008年 査読有り
-
Proceeding of 10th The East Asia Conference of Radiological Technologists 93-94 2008年 査読有り
-
Proceeding of IRPA12 International Congress of the International Radiation Protection Association 1-5 2008年 査読有り
-
Proceedings of Journal of KTJ Radiological Technologists 95-97 2007年
-
Proceedings of Journal of KTJ Radiological Technologists 97-98 2007年
-
Proceedings of Journal of KTJ Radiological Technologists 93-94 2007年
-
Proceedings of Journal of KTJ Radiological Technologists 99-100 2007年
-
医用画像情報学会雑誌 23(3) 100-104 2006年 査読有りInterslice sensitivity variation in magnetic resonance imaging (MRI) is said to be attributable to crosstalk. Crosstalk is a phenomenon in which deterioration of the rectangular profile of the RF pulse frequency characteristics leads to poor slice profiles, resulting in interference between slices. In the present study, the ideal characteristics of multislice profiles were analyzed through numerical simulation with the Bloch equation using sinc symmetrical RF pulses. The effects of the slice excitation order on the slice profile were also examined, comparing interleaved acquisition and sequential acquisition. The results of the simulation showed that the order of image acquisition affects the slice profile.
-
Proceedings of Journal of KTJ Radiological Technologists 83-84 2006年
-
Proceedings of Journal of KTJ Radiological Technologists 75-76 2006年
-
Magnetic Resonance in Medical Sciences 5(4) 179-189 2006年q-space diffusion analysis is a method to obtain the probability density function of the translational displacement of diffusing water molecules. Several quantities can be extracted from the function that indicate a characteristic of the water diffusion in tissue, e.g., the mean displacement of the diffusion, probability for zero displacement, and kurtosis of the function. These quantities are expected to give information about the microstructure of tissues in addition to that obtained from the apparent diffusion coefficient (ADC) however, this method requires high q (i.e., high b) values, which are undesirable in practical applications of the method using clinical magnetic resonance (MR) imaging equipment. We propose a method to obtain certain quantities that indicate a characteristic of the diffusion and that uses low q-value measurements. The quantities we can obtain are the moments of translational displacement, R the n-th order moment is defined as the average of Rn (n: integer). Kurtosis can also be calculated from the second and fourth moments. We tried to map the moments and kurtosis using clinical MR imaging equipment. We also estimated the inherent errors of the moments obtained. Our method requires precision in measuring spin echo signals and setting q values rather than using high q-value measurements. Although our results show that further error reductions are desired, our method is workable using ordinary clinical MR imaging equipment.
書籍等出版物
8講演・口頭発表等
85-
The International Session of 29th Japan Association of Radiological Technologists Conference 2013年9月
-
The 29th Japan Association of Radiological Technologists Conference 2013年9月
-
The International Session of 29th Japan Association of Radiological Technologists Conference 2013年9月
-
The International Session of 29th Japan Association of Radiological Technologists Conference 2013年9月
-
The International Session of 29th Japan Association of Radiological Technologists Conference 2013年9月
作成した教科書、教材、参考書
4-
件名クラーク X線撮影技術学終了年月日2009/11概要放射線撮影技術学に関する撮影技法を記載
-
件名診療放射線技師 国家試験 完全マスター終了年月日2009/06概要放射線技師国家試験解説
-
件名新・医用放射線技術実験 臨床編 第2版終了年月日2010/02概要放射線機器工学実験でのMRI装置を用いたスライス厚実験内容を記載
-
件名実践 医用画像解析ハンドブック終了年月日2011/11概要心臓tagging法の評価解析ソフトウエア作成の手順を記載
教育方法・教育実践に関する発表、講演等
1-
件名第16回東アジア学術交流大会 インターナショナルシンポジウム終了年月日2010/10概要日本国内での診療放射線技師養成機関の現状と今後の方向性を述べた.
その他教育活動上特記すべき事項
1-
件名The 45th Anniversary of the SRTA founding Conference and International Symposium for Korea-Taiwan-Japan,終了年月日2010/03概要MRIの電磁波被曝の現状と考え方.