医学部 乳腺外科

西原 裕盛

ニシハラ ユウセイ  (Yusei Nishihara)

基本情報

所属
藤田医科大学 医療科学部 特別研究員
学位
博士(医療科学)(2026年3月 藤田医科大学)

研究者番号
61037272
ORCID ID
 https://orcid.org/0009-0000-4127-1390
J-GLOBAL ID
202601006839779605
researchmap会員ID
R000101702

論文

 11
  • Masanao Kobayashi, Yusei Nishihara, Tomonobu Haba, Shigeki Kobayashi
    Radiological Physics and Technology 2026年12月  
  • Masanao Kobayashi, Yusei Nishihara, Tomonobu Haba, Shigeki Kobayashi
    Radiation Physics and Chemistry 248 114060-114060 2026年11月  
  • Yusuke Ito, Yusei Nishihara, Masanao Kobayashi, Tomoya Hibino, Yasuki Asada
    Journal of Applied Clinical Medical Physics 27(9) 2026年8月18日  
    Abstract Background In computed tomography (CT), radiation dose is commonly evaluated using system‐displayed metrics such as CTDIvol; however, variations in X‐ray beam quality may influence organ absorbed dose even under identical CTDIvol conditions. Purpose To investigate the impact of X‐ray beam quality, including tube voltage and beam‐shaping filters, on organ absorbed dose in chest computed tomography (CT) under identical CTDIvol conditions, with particular emphasis on spectral characteristics and energy‐dependent dose conversion. Methods Half‐value layer (HVL) measurements were performed using the aluminum attenuation method to determine effective energy under different tube voltage conditions (80, 100, 120, and 135 kV, and 120 kV with a silver [Ag] filter). X‐ray spectra were measured using a CdTe‐based spectrometer with a 90°Compton scattering configuration, and mean photon energy was calculated from the measured spectra. Absorbed doses in the breast and lung were evaluated using optically stimulated luminescence (OSL) dosimeters placed in an anthropomorphic phantom. Scan parameters were adjusted to maintain a constant CTDIvol (6.2 mGy) across all conditions. Absorbed dose was calculated from air kerma using f‐factors derived from both effective energy and mean photon energy. Results Effective energy increased with tube voltage and was markedly elevated by the Ag filter. Spectral measurements demonstrated substantial reduction of low‐energy photons and beam hardening under the Ag condition. Despite identical CTDIvol, both air kerma and absorbed dose varied with beam quality. Absorbed dose generally increased with effective energy in both tissues; however, under the 120 kV + Ag condition, the two tissues diverged: the lung absorbed dose decreased despite the higher effective energy, whereas the breast absorbed dose continued to increase. When the mean photon energy was used instead, this discrepancy was resolved differently: the absorbed dose decreased under the 120 kV + Ag condition in both the breast and the lung. This tissue‐dependent sensitivity to the choice of energy metric was attributable to the energy dependence of the f‐factor, which approached or exceeded unity in the breast under the Ag condition. Conclusions Organ absorbed dose in chest CT varies with beam quality even under identical CTDIvol conditions, and this variation is tissue‐dependent. Effective energy and mean photon energy can lead to different, and in the breast even opposite, conclusions regarding the direction of dose change under the same irradiation condition. Specifically, under standard (non‐filtered) conditions, mean‐photon‐energy‐based absorbed doses in the breast were approximately 4%‐5% higher than effective‐energy‐based estimates, whereas under the 120 kV + Ag condition this relationship reversed, with mean‐photon‐energy‐based doses approximately 1.6% lower. Although the magnitude of this reversal was relatively small, it was consistent and reproducible across repeated measurements. These findings highlight that the choice of energy metric used to convert air kerma to absorbed dose can meaningfully affect organ dose assessment in CT dosimetry, particularly when the f‐factor approaches or exceeds unity.
  • Masanao Kobayashi, Juria Suzuki, Yusei Nishihara, Tomonobu Haba, Shigeki Kobayashi
    Radiation Protection Dosimetry 2026年7月14日  
    Abstract In diagnostic computed tomography (CT), radiological technologists and assisting staff may need to remain inside the CT room during patient assistance. Understanding temporal changes in scattered radiation distribution is therefore important for reducing occupational exposure. Conventional measurements mainly provide instantaneous dose rates or accumulated doses and are less suited to intuitively capturing temporal changes during CT scanning. This study conducted a fundamental investigation of a visualization approach, defined as dynamic dose distribution (DDD), based on time-resolved air kerma measurements obtained with a semiconductor survey meter. Scattered radiation was measured during chest-to-pelvis helical CT scanning of an anthropomorphic phantom under fixed tube current and automatic exposure control conditions. DDD allowed temporal changes in scattered radiation distribution to be visually identified in relation to tube current modulation, patient table position, and measurement height. DDD may provide useful temporal information for considering staff positioning and reducing occupational exposure.
  • Hironori Otsubo, Tomonobu Haba, Yusei Nishihara, Masanao Kobayashi, Rei Ito, Yoshiki Sunada, Tomoya Ishida, Haruki Ibamoto, Shigeki Kobayashi
    Radiological Physics and Technology 2026年5月8日  

MISC

 6

講演・口頭発表等

 65

担当経験のある科目(授業)

 1

所属学協会

 2

共同研究・競争的資金等の研究課題

 1