Takanobu Kiss, Masayoshi Inoue, Kohei Higashikawa, Takumi Suzuki, Lin Lyu, Ken Takasaki, Kazutaka Imamura, Yuta Onodera, Dai Uetsuhara, Akira Ibi, Teruo Izumi, Hitoshi Kitaguchi
CRYOGENICS 80 221-228 2016年12月 査読有り
We have investigated flux flow dissipation in typical two kinds of HTS tapes, i.e., a Bi-2223 multi-filamentary tape and a RE-123 coated conductor (CC) from the view point of heat load under over current conditions. Based on systematic measurements on current-voltage characteristics, the nonlinear flux flow dissipation has been described analytically by taking into account current sharing in metallic sheath or stabilization layer. Flux flow dissipation in the RE-123 CC shows much steeper temperature dependence than that of the Bi-2223 tape. As a result, attainable cooling power becomes smaller in the RE-123 CC in comparison with that of Bi-2223 tape even if the same cooling condition. In other word, acceptable temperature rise in the RE-123 CC is small at over current condition, whereas moderate temperature dependence in the Bi-2223 tape allows stable operation even if the bias current exceeds the critical current. Influence of spatial inhomogeneity in the both HTS tapes has also been investigated. Longitudinal variation of local critical current, I-c, and its statistical behavior have been characterized by use of reel-to-reel scanning Hall probe microscopy. It has been found that the flux flow dissipation is possibly localized more than one order higher than that of the average value due to discrete local I-c drops. (C) 2016 Published by Elsevier Ltd.