研究者業績
基本情報
- 所属
- 藤田医科大学 医学部 放射線診断学講座 臨床教授
- 学位
- 医学士(1994年3月 神戸大学医学部)博士(医学)(2000年9月 神戸大学大学院医学研究科)
- J-GLOBAL ID
- 201301059890537338
- researchmap会員ID
- 7000004230
研究分野
1経歴
7-
2025年1月 - 現在
-
2020年4月 - 2024年12月
-
2009年4月 - 2020年3月
-
2008年10月 - 2009年3月
-
2003年4月 - 2007年3月
学歴
2-
1995年4月 - 2000年9月
-
1988年4月 - 1994年3月
受賞
11論文
176-
Japanese journal of radiology 2026年5月20日PURPOSE: Since the clinical application of computed tomography (CT), cardiac and respiratory motion artifacts have caused decreased image quality and reduced detection or quantitative or qualitative evaluation of lung parenchymal or vascular abnormalities on chest CT with lung window settings in patients with pulmonary diseases. Recently, a deep learning (DL)-based motion correction algorithm (CLEAR Motion) has been developed and clinically used for chest CT. We hypothesized that CLEAR Motion can significantly reduce motion artifacts on chest CT examinations relative to conventional chest CT images reconstructed without CLEAR Motion. The purpose of this study was to determine the utility of CLEAR Motion for image quality improvement in chest CT with lung window settings in patients with various pulmonary diseases. MATERIALS AND METHODS: Fifty-six consecutive patients with various thoracic diseases underwent non-electrocardiogram-gated chest helical CT examination using a 320-detector row CT and underwent reconstruction using the conventional reconstruction method and CLEAR Motion. To compare the quantitative image quality, the cardio-pulmonary edge distance (CPED) and slope (CPES) were measured on each CT scan in the axial plane. Comparing cardiac motion reduction capability, overall image quality, cardiac motion artifact, and region conspicuity were visually assessed in the lung window setting on the axial, coronal, and sagittal planes. The paired t-test and Wilcoxon signed-rank test were then performed. RESULTS: The CPEDs and CPESs of the entire lung and left lung on CT with CLEAR Motion were significantly superior to those of CT without CLEAR Motion (p < 0.001). The overall image quality, cardiac motion artifact, and region conspicuity on CT with CLEAR Motion were significantly higher than those without CLEAR Motion on each plane (p < 0.001). CONCLUSION: The DL-based motion correction algorithm named as 'CLEAR Motion' has a potential to improve image quality on chest CT with lung window setting in patients with pulmonary diseases.
-
Magnetic resonance in medical sciences : MRMS : An official journal of japan society of magnetic resonance in medicine 2026年4月24日PURPOSE: To evaluate whether reverse encoding distortion correction (RDC) improves image quality and maintains apparent diffusion coefficient (ADC) measurements in diffusion-weighted imaging (DWI) on female pelvic MRI using a 1.5-T in in vitro and in vivo studies. METHODS: This retrospective, institutional review board-approved study included both in vitro and in vivo analyses of 31 women (mean age, 41 ± 15 years; range, 24-80 years) who underwent pelvic MRI between January and March 2022. T2-weighted image (T2WI) and DWI with and without RDC were acquired, and ADC maps were generated. Quantitative metrics included SNR, contrast-to-noise ratio (CNR), ADC values, and deformation ratio (DR), defined as the proportional area discrepancy between DWI and T2WI for the uterine corpus, cervix, ovary, and lesions. Qualitative assessments-overall image quality (OIQ), deformation severity (DS), and diagnostic confidence level (DCL)-were independently scored by 2 blinded radiologists using 5-point scales. RESULTS: In vitro SNR and ADC values showed no significant differences between DWI with and without RDC, with strong correlations to reference measurements (ρ = 0.99, P < 0.001). In vivo, SNR, CNR, and ADC values of the myometrium, cervix, and ovary did not differ significantly between 2 methods (P > 0.05). DRs were significantly lower in DWI with RDC than in DWI without RDC (P ≤ 0.0003). ADC values showed strong correlations between DWI with and without RDC on uterine corpus, cervix, ovary and lesions (ρ = 0.82-0.90, P < 0.001). Qualitative scores improved with RDC: higher OIQ (P = 0.0004), lower DS (P = 0.0004), and higher DCL (P = 0.03). Interobserver agreement ranged from substantial to almost perfect (κ = 0.78-0.97). CONCLUSION: RDC improves image quality and reduces image distortion in DWI on female pelvic MRI at a 1.5-T, while maintaining ADC measurements in in vitro and in vivo settings.
-
Magnetic resonance in medical sciences : MRMS : An official journal of japan society of magnetic resonance in medicine 2026年4月10日PURPOSE: The present study directly compared the quantitative capabilities of regional perfusion and pulmonary functional change assessments among electrocardiography (ECG)- and photoplethysmography (PPG)-monitored phase-resolved functional lung (PREFUL) MRI and dynamic contrast-enhanced (CE) perfusion MRI in thoracic oncologic patients. METHODS: Seventeen thoracic oncologic patients prospectively underwent ECG- and PPG-monitored PREFUL MRI, dynamic CE-perfusion MRI, and pulmonary function tests. ECG- and PPG-monitored perfusion-weighted PREFUL MRI (PW-MRI) and quantitative perfusion maps from dynamic CE-perfusion MRI were generated. Regional perfusions were determined using ROI measurements. For each patient, the overall perfusion from each method was determined as the average ROI measurement value. To determine the relationship between regional perfusion among all methods, Pearson's correlations were performed. Tukey's honest significant difference test was performed to compare regional perfusion among ventral, middle, and dorsal slice positions on ECG- and PPG-monitored PW-MRI and quantitative perfusion maps. To assess the pulmonary functional loss evaluation capability of each MRI method, each overall perfusion was correlated with %VC and %FEV1 using Pearson's correlation. RESULTS: The correlation of regional perfusion between ECG- and PPG-monitored PW-MRI was significant and good (r = 0.79, P < 0.0001). However, the correlations between ECG- or PPG-monitored PW-MRI and quantitative perfusion maps were assessed as significant and fair (ECG: r = 0.4, P < 0.0001; PPG: r = 0.36, P < 0.0001). ECG- and PPG-monitored PW-MRI demonstrated significantly higher perfusion than the quantitative perfusion map (P < 0.0001). Furthermore, ECG-and PPG-monitored PW-MRI and quantitative perfusion maps had significant and moderate correlations (%VC: 0.60 ≤ r ≤ 0.63, P < 0.05; %FEV1: 0.52 ≤ r ≤ 0.69, P < 0.05). CONCLUSION: ECG- and PPG-monitored PREFUL MRI had similar potential to dynamic CE-perfusion MRI for quantitatively assessing regional perfusion and pulmonary functional changes in thoracic oncologic patients. Furthermore, PPG-monitored PREFUL MRI showed little difference in regional perfusion evaluation compared with ECG-monitored PREFUL MRI and the potential to play a complementary role in this setting.
-
European radiology experimental 10(1) 2026年3月31日BACKGROUND: We compared the capabilities of quantitatively assessed paired inspiratory-expiratory area-detector computed tomography (ADCT) for pulmonary functional loss and disease severity evaluations between upright and supine ADCT in matched progressive pulmonary fibrosis (PPF) patients. MATERIALS AND METHODS: This retrospective cohort consisted of age-, sex-, and underlying disease-matched patients with PPF who underwent paired inspiratory-expiratory CT on upright ADCT (n = 40) and supine ADCT (n = 40), pulmonary function tests, and disease severity assessment. Based on CT data, the absolute values of the logarithm of the Jacobian determinant and warp-field magnitude of the whole lung and all lobes were calculated. Stepwise regression analyses were performed. RESULTS: On supine ADCT, both indices of the left lower lobe (LLL) were the first and only steps for pulmonary function test results and CT-assessed disease severity (absolute value of the logarithm of the Jacobian determinant: 0.139 ≤ r2 ≤ 0.175, 0.007 ≤ p ≤ 0.018; absolute value of the warp-field magnitude: 0.371 ≤ r2 ≤ 0.447, p < 0.001). However, on upright ADCT, both indices indicated that LLL was the first step and the right lower lobe was the second step for pulmonary function test results and CT-assessed disease severity (0.503 ≤ r2 ≤ 0.674, p < 0.001 or 0.000 < p ≤ 0.006 and 0.474 ≤ r2 ≤ 0.652, 0.002 ≤ p ≤ 0.045, respectively). CONCLUSION: Upright ADCT has equal to or better potential than supine ADCT for detecting pulmonary functional loss and evaluating disease severity when paired inspiratory-expiratory ADCT is applied in PPF patients. RELEVANCE STATEMENT: Upright ADCT has superior potential to supine ADCT for pulmonary functional loss and disease severity evaluations when paired inspiratory-expiratory ADCT is performed in patients with progressive pulmonary fibrosis (PPF). KEY POINTS: Matched progressive pulmonary fibrosis patients compared functional loss and disease severity evaluations between inspiratory-expiratory upright and supine area-detector CT. Clinical parameters demonstrated better correlations with upright than with supine inspiratory-expiratory area-detector CT. Warp-field magnitude showed better correlations with disease severities than the logarithm of the Jacobian determinant on each area-detector CT.
-
European journal of radiology 196 112647-112647 2026年3月PURPOSE: The purpose of this study was to directly compare diagnostic capability of inguinal herniation between upright area-detector CT (ADCT) and conventional supine ADCT under the Valsalva maneuver. MATERIALS AND METHODS: This retrospective study included 209 patients with 360 inguinal herniations and 123 patients without inguinal hernias. All patients underwent supine and upright ADCT for the evaluation of abdominal wall hernias within one week between May 2023 and March 2024. From this cohort, a total of 120 of 360 inguinal hernias and 120 of 304 non-inguinal hernias were computationally selected, and the probability of hernia was visually assessed by two board-certified general and abdominal radiologists with 5-point scales to assess subtypes of herniation. The final score for each hernia was determined as consensus of two investigators. To determine the capability of diagnosis for inguinal herniation in selected lesion groups, diagnostic performance was compared between upright and supine ADCTs using an ROC analysis. Then, sensitivity (SE), specificity (SP), and accuracy (AC) for differentiation of inguinal from non-inguinal hernias were compared between the two methods using McNemar's test. RESULTS: The area under the curve (AUC) of upright ADCT (AUC = 0.96) was significantly larger than that of supine ADCT (AUC = 0.93, p < 0.0001). Sensitivity (SE) and accuracy (AC) of upright ADCT (SE: 87.5 %, AC: 93.8 %) were significantly higher than those of supine ADCT (SE: 73.3 %, p < 0.0001; AC: 86.7 %, p < 0.0001). CONCLUSION: Upright ADCT has better potential for the diagnosis and subtype classification of inguinal herniation than conventional supine ADCT when applied under the Valsalva maneuver.
MISC
86書籍等出版物
10講演・口頭発表等
396-
Joint Annual Meeting ISMRM-ESMRMB 2014SMRT 23rd Annual Meeting 2014年5月 International Society of Magnetic Resonance in Medicine
-
Joint Annual Meeting ISMRM-ESMRMB 2014SMRT 23rd Annual Meeting 2014年5月 International Society of Magnetic Resonance in Medicine
-
Joint Annual Meeting ISMRM-ESMRMB 2014SMRT 23rd Annual Meeting 2014年5月 International Society of Magnetic Resonance in Medicine
-
第73回日本医学放射線学会学術集会 2014年4月 日本医学放射線学会 招待有り
-
第73回日本医学放射線学会総会 2014年4月 日本医学放射線学会
-
第73回日本医学放射線学会 2014年4月 日本医学放射線学会
-
第73回日本医学放射線学会学術集会 2014年4月 日本医学放射線学会
-
第73回日本医学放射線学会総会 2014年4月 日本医学放射線学会
-
Annual Meeting of European Congress of Radiology 2014 2014年3月 European Congress of Radiology
-
Annual Meeting of European Congress of Radiology 2014 2014年3月 European Congress of Radiology
-
Annual Meeting of European Congress of Radiology 2014 2014年3月 European Congress of Radiology
-
Annual Meeting of European Congress of Radiology 2014 2014年3月 European Congress of Radiology
-
ECR 2014 2014年3月 European Society of RadiologyPerfusion CTによる肺実質及び肺結節評価における被ばく低減法に関する検討
-
Annual Meeting of European Congress of Radiology 2014 2014年3月 European Congress of Radiology
-
ECR 2014 2014年3月 European Society of Radiology全身MRI, PET/CTおよびMR/PETにおける非肺がん患者の病期診断能に関する検討
-
Annual Meeting of European Congress of Radiology 2014 2014年3月 European Congress of Radiology
-
European Congress of Radiology 2014年3月 European Society of Radiology
-
Annual Meeting of European Congress of Radiology 2014 2014年3月 European Congress of Radiology
-
ECR 2014 2014年3月 European Society of Radiology非造影Perfusion MRIにおける肺がん患者の術後肺機能予測に関する検討
-
第6回呼吸機能イメージング研究会学術集会 2014年1月 呼吸機能イメージング研究会非造影Perfusion MRIにおける肺がん患者の術後肺機能予測に関する検討
-
RSNA 2013 2013年12月 Radiological Society of North America全身MRI, PET/CTおよびMR/PETにおける非肺がん患者の病期診断能に関する検討
-
99th Radiological Society of North America 2013年12月
-
The 99th Radiological Society of North America, Scientific Assembly and Annual Meeting. 2013年12月 Radiological Society of North America
-
RSNA 2013 2013年12月 Radiological Society of North AmericaPerfusion CTによる肺実質及び肺結節評価における被ばく低減法に関する検討
-
RSNA 2013 2013年12月 Radiological Society of North America酸素造影MRIの喘息患者における肺機能障害及び臨床病期診断能に関する検討
-
RSNA 2013 2013年12月 Radiological Society of North America非造影Perfusion MRIにおける肺がん患者の術後肺機能予測に関する検討
-
99th Radiological Society of North America 2013年12月
-
第53回日本核医学会学術総会 2013年11月 日本核医学会全身MRI, PET/CTおよびMR/PETにおける肺がん患者の病期診断能に関する検討
-
99th Annual Meeting of Radiological Society of North America 2013年11月 Radiological Society of North America
-
99th Annual Meeting of Radiological Society of North America 2013年11月 Radiological Society of North America
-
99th Annual Meeting of Radiological Society of North America 2013年11月 Radiological Society of North America
-
99th Annual Meeting of Radiological Society of North America 2013年11月 Radiological Society of North America
-
第41回日本磁気共鳴医学会大会 2013年9月 日本磁気共鳴医学会全身MRI, PET/CTおよびMR/PETにおける肺がん患者の病期診断能に関する検討
-
第41回日本磁気共鳴医学会大会 2013年9月 日本磁気共鳴医学会Time-SLIP法を用いた非造影MRAと造影4D-MRAによる3T MRIにおける肺静脈評価能の検討
-
第41回日本磁気共鳴医学会大会 2013年9月 日本磁気共鳴医学会非造影Perfusion MRIにおける肺がん患者の術後肺機能予測に関する検討
-
第72回日本医学放射線学会 2013年4月 日本医学放射線学会非小細胞肺癌患者における非造影3T MR angiography,Time-resolved contrast-enhanced 3T MR angiography 及び造影CT の術前肺血管評価能に関する検討
-
第72回日本医学放射線学会 2013年4月 日本医学放射線学会肺癌患者の再発/・転移診断におけるQuick 3D with Double Fat Suppression Techniqueの全身3T MR検査における有用性に関する検討
-
ISMRM 21st Annual Meeting & Exhibition 2013年4月 International Society of Magnetic Resonance in Medicine喫煙者における超短エコー時間を用いたMRIの肺機能及び臨床病期評価における有用性に関する検討
-
ISMRM 21st Annual Meeting & Exhibition 2013年4月 International Society of Magnetic Resonance in Medicine膠原病肺患者における肺機能障害及び重症度評価における酸素造影MRIと薄層CTの有用性に関する検討
-
21th Scientific Meeting and Exhibition of International Society for Magnetic Resonance in Medicine. 2013年4月 International Society for Magnetic Resonance in Medicine
-
72nd Annual Meeting of the Japan Radiological Society 2013年4月 Japan Radiological Society
-
ISMRM 21st Annual Meeting & Exhibition 2013年4月 International Society of Magnetic Resonance in MedicineMulti-phase transmission RF systemの3T MR装置における有用性の評価
共同研究・競争的資金等の研究課題
11-
日本学術振興会 科学研究費助成事業 2025年4月 - 2028年3月
-
学術研究助成基金助成金/基盤研究(C) 2018年4月 - 2021年3月
-
学術研究助成基金助成金/基盤研究(C) 2015年4月 - 2018年3月
-
学術研究助成基金助成金/基盤研究(C) 2014年4月 - 2017年3月
-
科学研究費補助金/基盤研究(C) 2012年4月 - 2015年3月