先進診断システム探索研究部門

藤野 正之

fujino masayuki

基本情報

所属
藤田医科大学 医学部 医学科 講師
学位
医学博士(2015年3月 藤田医科大学)

J-GLOBAL ID
201801009992858830
researchmap会員ID
7000023626

論文

 85
  • Takashi Nakano, Masayuki Fujino, Masafumi Miyata, Tetsushi Yoshikawa
    Journal of Medical Systems 50(1) 2026年1月29日  
    Abstract Heart rate variability (HRV) is a well-established, noninvasive measure of autonomic nervous system activity and is associated with clinical outcomes. Although real-time monitoring of HRV is valuable in clinical practice, its effectiveness is often compromised by major challenges: high inter-individual variability and frequent data contamination from procedural artifacts. To address these challenges, we developed and validated a computational framework for robust and personalized real-time HRV analysis oriented toward clinical application. The framework performs simultaneous analysis and visualization of both time- and frequency-domain HRV indices and incorporates an adaptive alert algorithm that personalizes alert thresholds using the interquartile range of each patient’s own data. A workflow-integrated mechanism for manually annotating and excluding artifact-prone periods prevents procedural artifacts from skewing the statistical baselines, and a multi-scale visualization module provides a unified view of short-term fluctuations and long-term trends. While existing HRV tools are powerful for research or offline analysis, they often lack the integration of personalized alerting and workflow-oriented artifact management needed for bedside care. The proposed system uniquely combines personalized alerting, care-linked artifact exclusion, and multi-scale bedside visualization within a single real-time software package. The framework was validated using open-access electrocardiogram (ECG) databases and synthetic noise-contaminated signals, confirming robust R-wave detection across pediatric and adult recordings and under low signal-to-noise conditions. In addition, the framework was operationally validated at the bedside using ECG data from 24 newborn patients. By systematically addressing the core challenges of personalization and artifact management in a clinically integrated manner, this work represents a significant step toward translating real-time HRV analysis into routine vital sign management and, ultimately, improved patient outcomes.
  • 川井 有里, 斎藤 和由, 中島 葉月, 内藤 佳奈, 関谷 隆夫, 内田 英利, 神野 重光, 船戸 悠介, 中内 千春子, 眞鍋 正彦, 藤野 正之, 帽田 仁子, 西澤 春紀, 宮田 昌史
    日本周産期・新生児医学会雑誌 60(Suppl.1) P357-P357 2024年6月  
  • 帽田 仁子, 神野 重光, 中内 千春子, 船戸 悠介, 眞鍋 正彦, 小島 有紗, 川井 有里, 藤野 正之, 宮田 昌史
    日本口蓋裂学会雑誌 49(2) 57-57 2024年4月  
  • 川井 有里, 神野 重光, 中内 千春子, 船戸 悠介, 真鍋 正彦, 小島 有紗, 内田 英利, 藤野 正之, 帽田 仁子, 斉藤 和由, 宮田 昌史
    日本小児科学会雑誌 128(2) 384-384 2024年2月  
  • 船戸 悠介, 神野 重光, 中内 千春子, 眞鍋 正彦, 川井 有里, 小島 有紗, 藤野 正之, 帽田 仁子, 宮田 昌史
    日本小児科学会雑誌 128(1) 74-74 2024年1月  

MISC

 24

その他

 2