研究者業績
基本情報
- 所属
- 藤田医科大学 医療科学部 臨床検査学科 臨床生理・画像情報解析学領域 准教授
- 学位
- 博士(医学)
- J-GLOBAL ID
- 200901091924557501
- researchmap会員ID
- 1000205084
研究分野
1委員歴
8-
2021年6月 - 現在
-
2018年6月 - 現在
-
2011年4月 - 現在
-
2009年4月 - 現在
-
2017年4月 - 2022年3月
受賞
4-
2005年9月
-
2001年6月
論文
69-
Epilepsia open 2024年12月3日OBJECTIVE: Epilepsy treatment with anti-seizure medications (ASMs) is based on careful assessment of the balance between the likelihood of further seizures and the risk of side effects of treatment. However, there is currently no established biomarker to ascertain seizure control status with ASMs. High-frequency oscillations (HFOs), transient bursts of EEG activity with frequencies beyond 80 Hz, are a new and promising noninvasive epilepsy biomarker. We compared the risk of scalp HFO appearance between pediatric patients with good and poor seizure control by treatment with ASMs. METHODS: A total of 72 epilepsy patients (aged 0-18 years, 39 males) with good and poor seizure control with ASMs participated in this study. We applied a validated automated detector to determine HFO and spike. We calculated the odds ratios (ORs) for scalp HFO and spike appearance according to seizure control status by multiple logistic regression analysis. RESULTS: Scalp HFO was seen more commonly and with a significantly higher detection rate in patients with poor seizure control as compared with patients with good seizure control for both ripple and fast ripple. These significant associations were found for both focal and generalized epilepsy. The ORs for scalp HFO appearance adjusted for confounding factors were significantly higher in patients with poor seizure control compared to those with good seizure control (ripple: OR [95% CI] = 11.91 [2.21-64.30], p = 0.004; fast ripple: 4.98 [1.03-24.09], p = 0.046). There were no significant associations between spike appearance and seizure control status. SIGNIFICANCE: We found an increased risk of scalp HFO appearance in patients with poor seizure control. The results of this study support that scalp HFO is associated with patients having frequent seizures after treatment in both ripple and fast ripple. PLAIN LANGUAGE SUMMARY: This study analyzed scalp high-frequency oscillations and spikes in pediatric patients with various types of epilepsy who were being treated using ASMs. The results showed that an increased risk of scalp HFO appearance was observed in patients with poor seizure control compared to those with good seizure control. These findings were observed in both the ripple (80-250 Hz) and fast ripple (250-500 Hz) bands. The scalp HFO is associated with patients having frequent seizures after treatment in both ripple and fast ripple.
-
Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society 2023年10月30日INTRODUCTION: High-frequency oscillation (HFO) in scalp electroencephalography is a promising new noninvasive prognostic epilepsy biomarker, but further data are needed to ascertain the utility of this parameter. The present work investigated the association between epileptic activity and scalp HFO in pediatric patients with various types of epilepsy, using multivariable regression models to correct for possible confounding factors. METHODS: The authors analyzed 97 subjects who were divided into groups with active epilepsy (within 1 year of seizure), seizure-free epilepsy (>1 year without seizure), and nonepilepsy. Regarding the frequency of seizure occurrence as an indicator of epileptic activity, we categorized subjects into four groups (Daily/Weekly, Monthly, Yearly, and Rarely). RESULTS: Multiple linear regression analysis showed that the scalp HFO detection rate was significantly higher in patients with active epilepsy than in those with nonepilepsy (β [95% confidence interval] = 2.77 [1.79-4.29]; P < 0.001). The association between scalp HFO detection rate and frequency of seizure occurrence was highest in the Daily/Weekly group (β [95% confidence interval] = 3.38 [1.57-7.27]; P = 0.002), followed by Monthly and Yearly groups (β [95% confidence interval] = 2.42 [1.02-5.73]; P = 0.046 and 0.36 [0.16-0.83]; P = 0.017). In addition, HFO duration, number of peaks, and number of channels detected were significantly higher in patients with active epilepsy. CONCLUSIONS: Pediatric patients with active epilepsy and high frequency of seizure occurrence exhibited a higher scalp HFO detection rate. These results may help to establish HFO detectable by noninvasive scalp electroencephalography as a biomarker of active epilepsy in pediatric patients.
-
Genetic testing and molecular biomarkers 27(8) 239-247 2023年8月Background: The increasing prevalence of non-alcoholic fatty liver disease (NAFLD) has become a global health problem. NAFLD has few initial symptoms and may be difficult to detect early, so there is need for a minimally invasive early detection marker. We hypothesized that miR-122 and miR-20a levels combined, as the miR-122/miR-20a ratio might detect NAFLD more sensitively. Methods: This study involved 167 participants with low alcohol intake. Those who had an increase in echogenicity of the liver parenchyma and hepato-renal contrast on ultrasonography were classified as the NAFLD group (n = 44), which was further classified into mild (n = 26) and severe (n = 18) groups based on echogenic intensity and hepatic vessel and diaphragm visualization. Participants without fatty liver were included in the normal group, except for those with an abnormal body mass index, glycated hemoglobin, and systolic blood pressure (n = 123) values. Serum miR-122 and miR-20a expression levels in participants were measured by real-time polymerase chain reaction, and the miR-122/miR-20a was calculated. Results: In the NAFLD group, miR-122 expression was significantly higher and the miR-20a was significantly lower than in the normal group, in agreement with previous studies. miR-122/miR-20a was also significantly higher in the NAFLD group. Receiver operating characteristic curve analysis was performed with miR-122/miR-20a as an NAFLD detection marker, and the area under the curve of miR-122/miR-20a was significantly larger than that of miR-122 or miR-20a alone. Conclusions: The miR-122/miR-20a ratio, combined with miR-122 and miR-20a levels, is a useful biomarker to detect NAFLD with high sensitivity.
MISC
96-
日本超音波医学会関西地方会学術集会 50回 54-54 2023年10月
書籍等出版物
7講演・口頭発表等
148-
American Association for The Study of Liver Diseases The Liver Meeting 2013 2013年
-
13th Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine Congress 2013年
-
13th Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine Congress 2013年
-
13th Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine Congress 2013年
-
13th Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine Congress 2013年
-
13th Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine Congress 2013年
-
日本超音波医学会 第83回学術集会 2010年
-
The Liver Meeting 2010 2010年
主要な所属学協会
4共同研究・競争的資金等の研究課題
3-
日本学術振興会 科学研究費助成事業 2016年4月 - 2020年3月
-
文部科学省科学研究費補助金 基盤研究(C) 2015年4月 - 2018年3月
-
文部科学省科学研究費補助金 基盤研究 2012年4月 - 2015年3月