医学部 循環器内科学

Shigefumi Fukui

  (福井 重文)

Profile Information

Affiliation
Associate professor, Department of Cardiology, Fujita Health University

J-GLOBAL ID
202101006176795923
researchmap Member ID
R000023466

Papers

 66
  • Kazuyoshi Saito, Sayuri Yamabe, Arisa Kojima, Hidetoshi Uchida, Yuki Takigawa, Chihiro Nakashima, Meiko Hoshino, Kayoko Takada, Shigefumi Fukui, Tetsushi Yoshikawa, Hideo Izawa, Akira Yamada
    Fujita medical journal, 12(1) 79-83, Feb, 2026  
    Reports regarding coronavirus disease 2019 (COVID-19) with Fontan circulation are limited. Most studies indicate a relatively good clinical outcome in which SARS-CoV-2 infection is abated; however, COVID-19 can still cause severe pneumonia, and some studies report circulatory breakdown associated with acute respiratory distress syndrome in patients with Fontan circulation. We present the case of a 32-year-old Japanese woman with right isomerism and a single right ventricle who had undergone a fenestrated extracardiac total cavopulmonary connection (Fontan operation), atrioventricular valve replacement, and pacemaker implantation. Despite receiving three doses of the severe acute respiratory syndrome coronavirus 2 mRNA vaccine, the patient contracted COVID-19 and presented with pneumonia. Although her symptoms were mild, the patient was classified as high-risk based on the European Society of Cardiology risk stratification guidelines for COVID-19 in patients with adult congenital heart disease and was admitted to the hospital. Initially, the patient received only symptomatic treatment. However, 2 days later, the patient's COVID-19 condition worsened to moderate grade level II (SpO2 ≤93%, oxygen demand), with SpO2 dropping from 95% to 88% on room air. Treatment with remdesivir and dexamethasone following Japanese treatment protocols resulted in clinical improvement and discharge without hemodynamic complications. COVID-19 pneumonia risks disrupting Fontan circulation in affected patients. This case illustrates the importance of prompt risk stratification using anatomical and physical evaluation and adherence to treatment guidelines in the management of patients with Fontan circulation and COVID-19.
  • Takaaki Fujii, Sayuri Yamabe, Yoshiro Tsuruta, Yu Kawada, Tatsuya Mizoguchi, Masashi Yokoi, Kento Mori, Tsuyoshi Ito, Shuichi Kitada, Toshihiko Goto, Shigefumi Fukui, Hideo Izawa, Yoshihiro Seo
    Clinical case reports, 14(1) e71656, Jan, 2026  
    We present a case of a 51-year-old woman with atrial septal defect (ASD) masked by pulmonary arterial hypertension (PAH). Three months after PAH treatment with a combination of endothelin receptor antagonist and phosphodiesterase five inhibitor, the transthoracic echocardiography revealed left-to-right shunting through a secundum ASD. The pulmonary vascular resistance decreased from 7.4 to 2.6 Wood units. Subsequent transcatheter closure of ASD using Occlutech Figulla Flex II device was successfully performed as a treat-and-repair strategy. Five months later, hemodynamics had normalized. Due to reduced shunt flow caused by PAH, ASD may not be detectable before treatment, so care must be taken not to overlook PAH associated with intracardiac defects.
  • 星野 芽以子, 山田 晶, 齋藤 和由, 服部 円香, 中嶋 千尋, 高田 佳代子, 福井 重文, 浅井 ゆみこ, 小島 有紗, 内田 英利, 井澤 英夫
    日本成人先天性心疾患学会雑誌, 15(1) 224-224, Jan, 2026  
  • Teiji Akagi, Hidehiko Hara, Hideaki Kanazawa, Shigefumi Fukui, Yoichiro Hashimoto, Yasuyuki Iguchi, Toru Iwama, Hiroharu Kataoka, Akio Kawamura, Hiroyuki Kawano, Koichi Oki, Hiroshi Yamagami
    Circulation journal : official journal of the Japanese Circulation Society, 90(1) 109-117, Jun 13, 2025  
    BACKGROUND: The AmplatzerTMPFO Occluder was approved for marketing in Japan in May 2019, and the Amplatzer PFO Occluder Japan Post-Marketing Surveillance (PFO Japan PMS) study started in December 2019. This analysis presents clinical outcomes of study patients through 1 year of follow-up. METHODS AND RESULTS: PFO Japan PMS is a prospective single-arm multicenter clinical study. Eligible patients were indicated for patent foramen ovale (PFO) closure and underwent an implant attempt with the AmplatzerTMPFO Occluder, with no age restrictions. PFO closure was evaluated at 1 year via a bubble study, and patients will be followed for 3 years. From December 2019 to July 2021, 500 patients were enrolled across 53 sites. The mean (±SD) patient age was 52.7±15.4 years, with 29.8% of patients aged >60 years. Low adverse event rates were observed through 1 year of follow-up, including atrial fibrillation (2.4%; predominantly transient and within the first 30 days) and ischemic stroke (0.6%). Among patients in whom a 1-year bubble study was performed, a high rate (91.5%) of clinically relevant PFO closure (<20 bubbles) was achieved. CONCLUSIONS: Through 1 year of follow-up in this real-world Japanese study with 30% of patients aged >60 years, a high degree of closure was achieved with the AmplatzerTMPFO Occluder, along with low rates of atrial fibrillation, ischemic stroke, and overall adverse events.
  • Teiji Akagi, Hidehiko Hara, Hideaki Kanazawa, Shigefumi Fukui, Yoichiro Hashimoto, Yasuyuki Iguchi, Toru Iwama, Hiroharu Kataoka, Akio Kawamura, Hiroyuki Kawano, Koichi Oki, Hiroshi Yamagami
    Circulation journal : official journal of the Japanese Circulation Society, 88(9) 1391-1397, Aug 23, 2024  
    BACKGROUND: The AmplatzerTM PFO Occluder was approved for marketing in Japan in May 2019, and the Amplatzer PFO Occluder Japan Post-marketing Surveillance (PFO Japan PMS) study was initiated in December 2019. This analysis presents 30-day clinical outcomes for PFO Japan PMS study patients. METHODS AND RESULTS: PFO Japan PMS is a prospective single-arm non-randomized multicenter clinical study. Eligible patients were indicated for patent foramen ovale (PFO) closure and underwent an implant attempt with the AmplatzerTM PFO Occluder. Technical success was defined as successful delivery and release of the occluder; procedural success was defined as technical success with no serious adverse events (SAEs) within 1 day of the procedure. The primary safety endpoint includes predefined device- and/or procedure-related SAEs through 30 days after the procedure. From December 2019 to July 2021, 500 patients were enrolled across 53 Japanese sites. The mean (±SD) patient age was 52.7±15.4 years, and 29.8% of patients were aged >60 years. Technical and procedural success rates were both high (99.8% and 98.8%, respectively). Further, there was only one primary safety endpoint event (0.2%): an episode of asymptomatic paroxysmal atrial fibrillation that occurred 26 days after the procedure. CONCLUSIONS: In this real-world Japanese study with almost one-third of patients aged >60 years, PFO closure with the AmplatzerTM PFO Occluder was performed successfully and safely, with a low incidence of procedure-related atrial arrhythmias.

Misc.

 196