研究者業績

中野 和也

ナカノ カズヤ  (Kazuya Nakano)

基本情報

所属
成蹊大学 理工学部 理工学科 准教授
千葉大学 フロンティア医工学センター  特別研究准教授
学位
博士(工学)(2013年3月 東京工業大学)

J-GLOBAL ID
201901011163076818
researchmap会員ID
B000349377

外部リンク

論文

 30
  • Masafumi Minakawa, Md Abdul Wares, Kazuya Nakano, Hideaki Haneishi, Yoshihisa Aizu, Yoshio Hayasaki, Tetsuo Ikeda, Hajime Nagahara, Izumi Nishidate
    Journal of biomedical optics 28(10) 107001-107001 2023年10月  
    SIGNIFICANCE: Evaluation of biological chromophore levels is useful for detection of various skin diseases, including cancer, monitoring of health status and tissue metabolism, and assessment of clinical and physiological vascular functions. Clinically, it is useful to assess multiple different chromophores in vivo with a single technique or instrument. AIM: To investigate the possibility of estimating the concentration of four chromophores, bilirubin, oxygenated hemoglobin, deoxygenated hemoglobin, and melanin from diffuse reflectance spectra in the visible region. APPROACH: A new diffuse reflectance spectroscopic method based on the multiple regression analysis aided by Monte Carlo simulations for light transport was developed to quantify bilirubin, oxygenated hemoglobin, deoxygenated hemoglobin, and melanin. Three different experimental animal models were used to induce hyperbilirubinemia, hypoxemia, and melanogenesis in rats. RESULTS: The estimated bilirubin concentration increased after ligation of the bile duct and reached around 18  mg/dl at 50 h after the onset of ligation, which corresponds to the reference value of bilirubin measured by a commercially available transcutaneous bilirubin meter. The concentration of oxygenated hemoglobin and that of deoxygenated hemoglobin decreased and increased, respectively, as the fraction of inspired oxygen decreased. Consequently, the tissue oxygen saturation dramatically decreased. The time course of melanin concentration after depilation of skin on the back of rats was indicative of the supply of melanosomes produced by melanocytes of hair follicles to the growing hair shaft. CONCLUSIONS: The results of our study showed that the proposed method is capable of the in vivo evaluation of percutaneous bilirubin level, skin hemodynamics, and melanogenesis in rats, and that it has potential as a tool for the diagnosis and management of hyperbilirubinemia, hypoxemia, and pigmented skin lesions.
  • Chen Ye 0001, Mami Kawasaki, Kazuya Nakano, Takashi Ohnishi, Eizo Watanabe, Shigeto Oda, Taka-Aki Nakada, Hideaki Haneishi
    Sensors 22(21) 8471-8471 2022年11月  査読有り
  • Kazuya Nakano, Hiroyuki Suzuki
    Applied Optics 61(30) 9010-9019 2022年10月18日  査読有り筆頭著者責任著者
    Double random phase encoding (DRPE) is vulnerable to known-plaintext attacks (KPAs) based on phase retrieval algorithms. We previously analyzed DRPE resistance to KPA cryptanalysis with multiple known plaintext–ciphertext image pairs and obtained secret keys at a higher probability rate than when performing KPA cryptanalysis using one known image pair. However, the robustness of KPA in the presence of noise or occlusion in DRPE is unclear. We analyzed KPA properties in relation to DRPE when white Gaussian noise was gradually added to the Fourier amplitude or phase of a known ciphertext complex amplitude image. Additionally, we analyzed KPA properties when the Fourier phase of the known ciphertext image was gradually occluded by zero-valued pixels. The results showed that KPAs performed using multiple known plaintext–ciphertext image pairs were largely affected by noise added to the Fourier phase and thus are not always a strong tool for DRPE cryptanalysis.
  • Tin Tin Khaing, Takayuki Okamoto, Chen Ye, Md Abdul Mannan, Gen Miura, Hirotaka Yokouchi, Kazuya Nakano, Pakinee Aimmanee, Stanislav S. Makhanov, Hideaki Haneishi
    Artificial Life and Robotics 27(1) 70-79 2022年2月  査読有り
    Retinitis pigmentosa (RP) is a group of genetic disorders, characterized by degeneration of photoreceptor cells which is the main cause of choroidal thinning. It is one of the leading causes of blindness worldwide. Thus, an investigation of choroidal changes is required for a better understanding of disease and diagnosis of RP. In this paper, we propose an automatic technique for measuring the choroidal parameters in optical coherence tomography (OCT) images of eyes with RP. The parameters include the total choroidal area (TCA), luminal area (LA), stromal area (SA), and choroidal thickness (CT). We applied our recently proposed, dense dilated U-Net segmentation model, called ChoroidNET, for segmenting the choroid layer and choroidal vessels for our RP dataset. Choroid segmentation is an important task since the measurement results depend on it. Comparison with other state-of-the-art models shows that ChoroidNET provides a better quantitative and qualitative segmentation of the choroid layer and choroidal vessels. Next, we measure the choroidal parameters based on the segmentation results of ChoroidNET. The proposed method achieves high reliability with an intraclass correlation coefficient (0.961, 0.940, 0.826, 0.916) for TCA, LA, SA, and CT, respectively.
  • Tin Tin Khaing, Takayuki Okamoto, Chen Ye, Md. Abdul Mannan, Hirotaka Yokouchi, Kazuya Nakano, Pakinee Aimmanee, Stanislav S. Makhanov, Hideaki Haneishi
    IEEE ACCESS 9 150951-150965 2021年11月3日  査読有り
    Understanding the changes in choroidal thickness and vasculature is important to monitor the development and progression of various ophthalmic diseases. Accurate segmentation of the choroid layer and choroidal vessels is critical to better analyze and understand the choroidal changes. In this study, we develop a dense dilated U-Net model (ChoroidNET) for segmenting the choroid layer and choroidal vessels in optical coherence tomography (OCT) images. The performance of ChoroidNET is evaluated using an OCT dataset that contains images with various retinal pathologies. Overall Dice coefficient of 95.1 +/- 0.4 and 82.4 +/- 2.4 were obtained for choroid layer and vessel segmentation, respectively. Comparisons show that among state-of-the-art models, ChoroidNET, which produces results that are consistent with ground truths, is the most robust segmentation framework.

MISC

 5

講演・口頭発表等

 109
  • 鈴木 裕之, 坂本 静生, 宮井 貴志, 中野 和也, 竹田 賢史, 鈴木 理道, 前田 大輔
    情報科学技術フォーラム講演論文集 2011年9月7日 FIT(電子情報通信学会・情報処理学会)運営委員会
  • 中野和也, 鈴木 裕之, 山口雅浩, 小尾高史, 大山永昭
    第5回新画像システム・情報フォトニクス研究討論会予稿集, B-5, pp.58-59 2011年5月
  • Kazuya Nakano, Hiroyuki Suzuki, Masahiro Yamaguchi, Takashi Obi, Nagaaki Ohyama
    22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD 2011年 SPIE-INT SOC OPTICAL ENGINEERING
    Double Random Phase Encoding (DRPE), which is a typical optical encryption technique, has been reported to be vulnerable to Known Plaintext-Attacks (KPAs) using a Phase Retrieval Algorithm (PRA). But the reported case in which the encryption key is successfully estimated was that the plain image was rather simple such as the image of a character. In addition, although Phase Only DRPE (PO-DRPE) was proposed to achieve more resistance to the KPA than Complex DRPE (C-DRPE) in which both amplitude and phase components are used as an encrypted image, no quantitative results about the relationship between the vulnerability and the plaintext image. In this paper, we show the result of quantitative analysis on KPA by PRA to C-DRPE and PO-DRPE, for the plaintext images of different characteristics. As a result of experiment, KPA to C-DRPE succeeded to estimate the correct key while the probability of success became lower when the number of non-zero pixel increases in the plaintext image. However, KPA to PO-DRPE enabled to estimate only "singular" keys, which are effective for no more than given plaintext/ciphertext image pair and far different from the correct encryption key. We also conducted KPA using two plaintext-ciphertext image pairs for KPA. In the case when two plaintext-ciphertext image pairs were given to KPA, the cryptanalysis succeeded with higher probability than the case of one. Moreover, the probability of success in the KPA was high even in PO-DRPE.
  • Kazuya Nakano, Hiroyuki Suzuki, Masahiro Yamaguchi, Takashi Obi, and Nagaaki Ohyama
    Frontiers in Optics (FiO) 2010, OSA (Optical Society of America) 2010年10月
  • 鈴木裕之, 中野和也, 山口雅浩, 小尾高史, 大山永昭
    第4回新画像システム・情報フォトニクス研究討論会予稿集, pp.41-42 2010年9月
  • 中野和也, 鈴木裕之, 山口雅浩, 小尾高史, 大山永昭
    応用物理学会学術講演会講演予稿集(CD-ROM) 2010年8月30日
  • 中野和也, 鈴木裕之, 山口雅浩, 小尾高史, 大山永昭
    応用物理学関係連合講演会講演予稿集(CD-ROM) 2010年3月3日
  • 中野和也, 福田一志, 長谷川純, 小栗慶之
    第23回PIXEシンポジウム 環境Ⅰ 9-4, pp.24. 2006年11月
  • 小栗慶之, 福田一志, 長谷川順, 中野和也, 林通晴, 金子順一, 笹公和
    第19回タンデム加速器及びその周辺技術の研究会報告集,pp.95-98. 2006年7月

担当経験のある科目(授業)

 8

所属学協会

 2

共同研究・競争的資金等の研究課題

 11

産業財産権

 2