Profile Information
- Affiliation
- Associate Professor, Institute of Space and Astronautical Science, Department of Space Astronomy and Astrophysics, Japan Aerospace Exploration Agency
- Degree
- 博士(理学)(Mar, 2004, 東京大学)
- Researcher number
- 60446599
- ORCID ID
https://orcid.org/0000-0003-0441-7404
- J-GLOBAL ID
- 202001021434500706
- researchmap Member ID
- R000012970
Research Interests
6Research Areas
2Research History
2Education
3-
Apr, 1999 - Mar, 2001
-
Apr, 1995 - Mar, 1999
Awards
2Major Papers
222-
Publications of the Astronomical Society of Japan, 70(6), Oct 1, 2018 Peer-reviewedCorresponding authorWe present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.
-
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 765 192-201, Sep 2, 2015 Peer-reviewedLead authorCorresponding authorThe Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and cadmium telluride (CdTe) sensors. The design of the SGD Compton camera has been finalized and the final prototype, which has the same configuration as the flight model, has been fabricated for performance evaluation. The Compton camera has overall dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel sensors. The detection efficiency of the Compton camera reaches about 15% and 3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed by 208 ASICs developed for the SGD. Good energy resolution is afforded by semiconductor sensors and low noise ASICs, and the obtained energy resolutions with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good background rejection capability due to better constraints on Compton kinematics. Compton camera energy resolutions achieved with the final prototype are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively, which satisfy the instrument requirements for the SGD Compton camera (better than 2%). Moreover, a low intrinsic background has been confirmed by the background measurement with the final prototype.
-
IEEE Transactions on Nuclear Science, 56(3) 777-782, Nov 4, 2008 Peer-reviewedLead authorCorresponding authorWe developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a fine position resolution and a large detection area, CdTe diode DSDs with indium (In) anodes have yet to be realized due to the difficulty posed by the segmented In anodes. CdTe diode devices with aluminum (Al) anodes were recently established, followed by a CdTe device in which the Al anodes could be segmented into strips. We developed CdTe double-sided strip devices having Pt cathode strips and Al anode strips, and assembled prototype CdTe DSDs. These prototypes have a strip pitch of 400 micrometer. Signals from the strips are processed with analog ASICs (application specific integrated circuits). We have successfully performed gamma-ray imaging spectroscopy with a position resolution of 400 micrometer. Energy resolution of 1.8 keV (FWHM: full width at half maximum) was obtained at 59.54 keV. Moreover, the possibility of improved spectral performance by utilizing the energy information of both side strips was demonstrated. We designed and fabricated a new analog ASIC, VA32TA6, for the readout of semiconductor detectors, which is also suitable for DSDs. A new feature of the ASIC is its internal ADC function. We confirmed this function and good noise performance that reaches an equivalent noise charge of 110 e- under the condition of 3-4 pF input capacitance.
-
Astrophysical Journal, 651(1 I) 421-437, Jul 3, 2006 Peer-reviewedLead authorCorresponding authorWe present results from quantitative modeling and spectral analysis of the high mass X-ray binary Vela X-1 obtained with the Chandra HETGS. The spectra exhibit emission lines from H-like and He-like ions driven by photoionization, as well as fluorescent emission lines from several elements in lower charge states. In order to interpret and make full use of the high-quality data, we have developed a simulator, which calculates the ionization and thermal structure of a stellar wind photoionized by an X-ray source, and performs Monte Carlo simulations of X-ray photons propagating through the wind. The emergent spectra are then computed as a function of the viewing angle accurately accounting for photon transport in three dimensions including dynamics. From comparisons of the observed spectra with the simulation results, we are able to find the ionization structure and the geometrical distribution of material in Vela X-1 that can reproduce the observed spectral line intensities and continuum shapes at different orbital phases remarkably well. It is found that a large fraction of X-ray emission lines from highly ionized ions are formed in the region between the neutron star and the companion star. We also find that the fluorescent X-ray lines must be produced in at least three distinct regions --(1)the extended stellar wind, (2)reflection off the stellar photosphere, and (3)in a distribution of dense material partially covering and possibly trailing the neutron star, which may be associated with an accretion wake. Finally, from detailed analysis of the emission lines, we demonstrate that the stellar wind is affected by X-ray photoionization.
-
IEEE Transactions on Nuclear Science, 52(5 III) 2045-2051, Oct, 2005 Peer-reviewedLead authorCorresponding authorWe are developing a Compton camera based on Si and CdTe semiconductor imaging devices with high energy resolution. In this paper, results from the most recent prototype are reported. The Compton camera consists of six layered double-sided Si Strip detectors and CdTe pixel detectors, which are read out with low noise analog ASICs, VA32TAs. We obtained Compton reconstructed images and spectra of line gamma-rays from 122 keV to 662 keV. The energy resolution is 9.1 keV and 14 keV at 356 keV and 511 keV, respectively. © 2005 IEEE.
-
Astrophysical Journal, 597(1 II), Sep 12, 2003 Peer-reviewedLead authorCorresponding authorWe report the detection of a fully-resolved, Compton-scattered emission line in the X-ray spectrum of the massive binary GX 301-2 obtained with the High Energy Transmission Grating Spectrometer onboard the Chandra X-ray Observatory. The iron K-alpha fluorescence line complex observed in this system consists of an intense narrow component centered at an energy of E = 6.40 keV and a redward shoulder that extends down to ~6.24 keV, which corresponds to an energy shift of a Compton back-scattered iron K-alpha photon. From detailed Monte Carlo simulations and comparisons with the observed spectra, we are able to directly constrain the physical properties of the scattering medium, including the electron temperature and column density, as well as an estimate for the metal abundance.
-
IEEE Transactions on Nuclear Science, 48(4 I) 950-959, Jul 20, 2001 Peer-reviewedCadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these imaging detectors in future hard X-ray and Gamma-ray astronomy missions are briefly discussed.
Misc.
232-
Proceedings of 38th International Cosmic Ray Conference — PoS(ICRC2023), Aug 18, 2023
Presentations
124-
日本天文学会2025年春季年会, Mar 19, 2025
Research Projects
17-
科学研究費助成事業, 日本学術振興会, Apr, 2024 - Mar, 2029
-
科学研究費助成事業 基盤研究(A), 日本学術振興会, Apr, 2025 - Mar, 2028
-
科学研究費助成事業 基盤研究(A), 日本学術振興会, Apr, 2021 - Mar, 2025
-
科学研究費助成事業 基盤研究(A), 日本学術振興会, Apr, 2020 - Mar, 2024
-
Grants-in-Aid for Scientific Research Grant-in-Aid for Scientific Research on Innovative Areas (Research in a proposed research area), Japan Society for the Promotion of Science, Jun, 2018 - Mar, 2023